{"schemaVersion":"1.1.0","subject":{"slug":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","kind":"panel","brand":"Canadian Solar","name":"HiHero+ CS6.2-66HB","canonical_name":"Canadian Solar HiHero+ CS6.2-66HB 645 W","model":"CS6.2-66HB-620 through CS6.2-66HB-645 (132 (2 x (11 x 6)) cells, N-type HJT, bifacial double glass); scored model CS6.2-66HB-645","certification_model":null,"certification_identities":[],"benchmark":{"min":620,"max":645,"scored":645,"unit":"W","metric":"rated power","policy":"highest_in_market","review_status":"current","note":"Retained scope is the intersection of the reviewed datasheet (620-645 W) with the Australian approval (615-665 W across 20 models). The approval extends beyond the reviewed sheet, so a later datasheet exists that was not located; the scored bin is the highest the reviewed source establishes, not the highest approved.","range_label":"620–645 W","scored_label":"645 W","market":"AU","series_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","series_definition":"Exact Australian-market family with one electrical and physical format.","scored_model":"CS6.2-66HB-645","evidence_scope":"exact_model","source":{"source_url":"https://static.csisolar.com/wp-content/uploads/2025/07/29095107/CS-Datasheet-Low-Carbon_HiHero-HJT_CS6.2-66HB_v1.5_EN_0.30-90%C2%B15.pdf","source_revision":"Canadian Solar HiHero+ HJT CS6.2-66HB datasheet v1.5 EN; CEC approved-module list queried 2026-08-18","checked":"2026-08-18"},"ranges":[{"min":620,"max":645,"unit":"W","market":"AU","range_label":"620–645 W","source_url":"https://static.csisolar.com/wp-content/uploads/2025/07/29095107/CS-Datasheet-Low-Carbon_HiHero-HJT_CS6.2-66HB_v1.5_EN_0.30-90%C2%B15.pdf","source_revision":"Canadian Solar HiHero+ HJT CS6.2-66HB datasheet v1.5 EN; CEC approved-module list queried 2026-08-18","checked":"2026-08-18"}],"supporting_metrics":[]},"score":74,"rubric_version":"2.11.0","url":"https://review.solar/products/canadian-solar-hihero-plus-cs6-2-66hb-620-645-au"},"envelope":{"version":"1.1.0","subject":{"type":"product","id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","identity_scope":"published_product_record","model":"CS6.2-66HB-620 through CS6.2-66HB-645 (132 (2 x (11 x 6)) cells, N-type HJT, bifacial double glass); scored model CS6.2-66HB-645","certification_model":null,"certification_identities":[],"benchmark_series_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au"},"recorded_at":null,"recorded_at_basis":null,"source_bindings":[{"source_id":"src_1f666e80727c88baedf2477184041d5b340c5be7469754a84b9a9e23d07a0c82","role":"supporting_source","object_scopes":["product"],"field_paths":[],"jurisdiction":null,"evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"benchmark_evidence","object_scopes":["exact_model"],"field_paths":["benchmark.source"],"jurisdiction":"AU","evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"benchmark_range_evidence","object_scopes":["product_series"],"field_paths":["benchmark.ranges.0"],"jurisdiction":"AU","evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Cell technology tier"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Encapsulation & frame construction"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Fire classification (IEC 61730)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Module efficiency (%)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Temp coefficient Pmax (%/C)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.NOCT (C)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Bifaciality factor (%)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Power tolerance (%)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Positive loading (MQT16, Pa)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Negative loading (MQT16, Pa)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Hail resistance"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.First-year degradation (%)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Annual degradation (%/yr)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Performance guarantee period (yrs)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Guarantee period (yrs)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Manufacturing track record"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.End-of-life & recycling disclosure"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"market_evidence","object_scopes":["market_overlay"],"field_paths":["evidence.market.AU"],"jurisdiction":"AU","evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","role":"primary_product_source","object_scopes":["exact_product_record"],"field_paths":[],"jurisdiction":null,"evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_7b8945c7fae51933a25b8f1c35d482e191ff4ad4e3313dec5cf77b167661aaa1","role":"market_evidence","object_scopes":["market_overlay"],"field_paths":["evidence.market.AU"],"jurisdiction":"AU","evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_7b8945c7fae51933a25b8f1c35d482e191ff4ad4e3313dec5cf77b167661aaa1","role":"research_priority_evidence","object_scopes":["market_priority"],"field_paths":["evidence.market_priorities.AU"],"jurisdiction":"AU","evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_a9bfedb79d428298105fa3665d4f4d6ccad01cd610777d12d1a290dd60259173","role":"supporting_source","object_scopes":["product"],"field_paths":[],"jurisdiction":null,"evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.PID (IEC TS 62804)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Salt mist (IEC 61701)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60","role":"criterion_evidence","object_scopes":["scored_criterion"],"field_paths":["audit_rows.Ammonia resistance (IEC 62716)"],"jurisdiction":null,"evidence_classes":["sourced"],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60","role":"market_evidence","object_scopes":["market_overlay"],"field_paths":["evidence.market.AU"],"jurisdiction":"AU","evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null},{"source_id":"src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60","role":"research_priority_evidence","object_scopes":["market_priority"],"field_paths":["evidence.market_priorities.AU"],"jurisdiction":"AU","evidence_classes":[],"checked_at":"2026-08-18","valid_from":null,"valid_to":null,"recorded_at":null,"superseded_at":null}],"events":[{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","object_id":null,"date":"2026-08-18","event_type":"product_evidence_checked","summary":"Core scorecard evidence checked","scope":"product_record","jurisdiction":null,"source_ids":[],"event_id":"evt_24f471c9f184f8eefa7429ac1ac5fd37b28bab5f8e5374994aaf84e4b485c4e3"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","object_id":null,"date":"2026-08-18","event_type":"market_evidence_checked","summary":"AU market evidence checked","scope":"market_overlay","jurisdiction":"AU","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","src_7b8945c7fae51933a25b8f1c35d482e191ff4ad4e3313dec5cf77b167661aaa1","src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60"],"event_id":"evt_f11e0521e859f1a8191cc2c26a93a1e82aceb30a8b7a01b92a5bf9fef346f254"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","object_id":null,"date":"2026-08-18","event_type":"benchmark_evidence_checked","summary":"Series benchmark evidence checked","scope":"scored_benchmark","jurisdiction":"AU","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"],"event_id":"evt_66c44b84b4e1c771b169ad42df7855f8cbd55f8dc6adef2a0464cde70853a711"}]},"change_history":{"schemaVersion":"1.0.0","baseline":{"dataset_revision":"rel_bcce8c246a65d51663134988c0ee07203ae81007281b5169834d130773e56cf0","product_count":232,"recorded_at":"2026-08-16","recorded_at_basis":"latest_record_date_in_baseline"},"current_release_id":"rel_8e27cb23d6c8c8a5f3fe2fa511ff542aaeadbf695ee7394f06e34a7ec7bcf2b7","events":[{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_6050f35a1edc5d43016d304c42e05e09eb296870b2cb2c2945385ed5d2767efe","event_type":"field_changed","field_path":"record.source_revision","field_label":"Source revision","before":"Built 2026-08-18 from Canadian Solar's HiHero+ HJT datasheet v1.5 (EN), text layer intact and cross-read against a render. Cell Type is given verbatim as \"HJT cells\". Scope note: the datasheet covers 620-645 W while the Australian approval runs 615-665 W across 20 models, so a later sheet exists that was not located; this record is scoped to the intersection of the reviewed sheet and the listing. The cover claims \"Up to 95% Power Bifaciality\" but the electrical table gives 90% with a +/-5% tolerance; the table value is recorded.","after":"Built 2026-08-18 from Canadian Solar's HiHero+ HJT datasheet v1.5 (EN), text layer intact and cross-read against a render. Cell Type is given verbatim as \"HJT cells\". Scope note: the datasheet covers 620-645 W while the Australian approval runs 615-665 W across 20 models, so a later sheet exists that was not located; this record is scoped to the intersection of the reviewed sheet and the listing. The cover claims \"Up to 95% Power Bifaciality\" but the electrical table gives 90% with a +/-5% tolerance; the table value is recorded. Re-verification 2026-08-18: salt mist recorded as certified without published severity from the Clean Energy Council enhanced listing for exact model CS6.2-66HB-645, under panel rubric v2.11.0 which added that band.","summary":"Source revision updated in the publication","scope":"product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"],"event_id":"chg_da8d083467fe421917f5def9df654c170fe180b2029187c8b267f1ac43e90d5c"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_6050f35a1edc5d43016d304c42e05e09eb296870b2cb2c2945385ed5d2767efe","event_type":"field_changed","field_path":"pillars.Durability (verified).score_precise","field_label":"Durability (verified) pillar score","before":68.2,"after":70.6,"summary":"Durability (verified) pillar score updated in the publication","scope":"scored_product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"],"event_id":"chg_c47f44a6ec6008877e1f24ded8d4392842b06485d4ea67bb2bc0e5cbd97dd533"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_5d976d36ea7e378531151c1c1519f72de884a0a7efb29990cfb7c07cebd6e53c","event_type":"product_added","field_path":"$record","field_label":"Product record","before":null,"after":{"kind":"panel","brand":"Canadian Solar","name":"HiHero+ CS6.2-66HB","model":"CS6.2-66HB-620 through CS6.2-66HB-645 (132 (2 x (11 x 6)) cells, N-type HJT, bifacial double glass); scored model CS6.2-66HB-645","score":73.2},"summary":"Product record entered the publication","scope":"product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"],"event_id":"chg_b9655d9b684ac0e1c7dfe04e4baa6c538a3d886aa47ecf29235aa16c2f1034c3"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_9b56334b40e212d5b10d9ea9c5449d238a939effd413c553c0097ac8f222795d","event_type":"field_changed","field_path":"pillars.Architecture & Design.score_precise","field_label":"Architecture & Design pillar score","before":74.2,"after":77.1,"summary":"Architecture & Design pillar score updated in the publication","scope":"scored_product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"],"event_id":"chg_b82815feecf18dd71b635f0743d434cf69ebd979fc8942c74da6f22cb678cc2d"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_6050f35a1edc5d43016d304c42e05e09eb296870b2cb2c2945385ed5d2767efe","event_type":"field_added","field_path":"audit_rows.Salt mist (IEC 61701).value","field_label":"Salt mist (IEC 61701)","before":null,"after":"Certified (IEC 61701), severity not published","summary":"Salt mist (IEC 61701) updated in the publication","scope":"scored_product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60"],"event_id":"chg_6cca1521eb068b5bb5876d0bf49721932ef827628dde14f50df97a513b3042dc"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_9b56334b40e212d5b10d9ea9c5449d238a939effd413c553c0097ac8f222795d","event_type":"field_changed","field_path":"pillars.Durability (verified).score_precise","field_label":"Durability (verified) pillar score","before":68.1,"after":68.2,"summary":"Durability (verified) pillar score updated in the publication","scope":"scored_product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"],"event_id":"chg_56a8e360195eb765d042774770a40122eb9244ec7f3a68a4887c7f9b225ade9f"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_6050f35a1edc5d43016d304c42e05e09eb296870b2cb2c2945385ed5d2767efe","event_type":"field_added","field_path":"audit_rows.Salt mist (IEC 61701).evidence_status","field_label":"Salt mist (IEC 61701): Evidence status","before":null,"after":"sourced","summary":"Salt mist (IEC 61701): Evidence status updated in the publication","scope":"scored_product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60"],"event_id":"chg_38408e126d3d5142afc0255fc49f015ad7bcc4675a72b1e86b06d4c0c8bbdf15"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_6050f35a1edc5d43016d304c42e05e09eb296870b2cb2c2945385ed5d2767efe","event_type":"field_changed","field_path":"score_precise","field_label":"Global score","before":73.8,"after":74.4,"summary":"Global score updated in the publication","scope":"scored_product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"],"event_id":"chg_1ef9c8a7e4ac7c97cdbeb3cf1103f1c15083260ac8d45684a46468ec623edd30"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_6050f35a1edc5d43016d304c42e05e09eb296870b2cb2c2945385ed5d2767efe","event_type":"field_added","field_path":"audit_rows.Salt mist (IEC 61701).source_urls","field_label":"Salt mist (IEC 61701): Evidence sources","before":null,"after":["https://cleanenergycouncil.org.au/industry/products/modules"],"summary":"Salt mist (IEC 61701): Evidence sources updated in the publication","scope":"scored_product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60"],"event_id":"chg_0a1cb8108940b1b8245f3c466f44c3836578b81fd9bd27ef988a42246a3c0b38"},{"subject_id":"canadian-solar-hihero-plus-cs6-2-66hb-620-645-au","release_id":"rel_9b56334b40e212d5b10d9ea9c5449d238a939effd413c553c0097ac8f222795d","event_type":"field_changed","field_path":"score_precise","field_label":"Global score","before":73.2,"after":73.8,"summary":"Global score updated in the publication","scope":"scored_product_record","jurisdiction":null,"valid_from":null,"valid_to":null,"recorded_at":"2026-08-18","recorded_at_basis":"latest_changed_record_date","source_ids":["src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"],"event_id":"chg_054d9e7ba58a5d4f70e74d1b9f2fff05971734aac3fdaecaadbffb6ab6dab910"}],"sources":[{"id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","url":"https://static.csisolar.com/wp-content/uploads/2025/07/29095107/CS-Datasheet-Low-Carbon_HiHero-HJT_CS6.2-66HB_v1.5_EN_0.30-90%C2%B15.pdf","label":"Primary datasheet","source_type":"datasheet","source_type_basis":"authored_display_type_or_url_heuristic","publisher":null,"licence":{"status":"unresolved","name":null,"url":null,"attribution":null,"permissions":{"display":null,"cache":null,"redistribute":null,"derive":null,"ai_use":null}},"locator_fingerprint":{"kind":"locator_sha256","sha256":"6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"},"content_fingerprint":null,"retrieval":null},{"id":"src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60","url":"https://cleanenergycouncil.org.au/industry/products/modules","label":"PID (IEC TS 62804)","source_type":"manufacturer","source_type_basis":"authored_display_type_or_url_heuristic","publisher":null,"licence":{"status":"unresolved","name":null,"url":null,"attribution":null,"permissions":{"display":null,"cache":null,"redistribute":null,"derive":null,"ai_use":null}},"locator_fingerprint":{"kind":"locator_sha256","sha256":"cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60"},"content_fingerprint":null,"retrieval":null}]},"approval_history":[],"sources":[{"id":"src_1f666e80727c88baedf2477184041d5b340c5be7469754a84b9a9e23d07a0c82","url":"https://cleanenergycouncil.org.au/api/PvModule/get","label":"PID (IEC TS 62804)","source_type":"manufacturer","source_type_basis":"authored_display_type_or_url_heuristic","publisher":null,"licence":{"status":"unresolved","name":null,"url":null,"attribution":null,"permissions":{"display":null,"cache":null,"redistribute":null,"derive":null,"ai_use":null}},"locator_fingerprint":{"kind":"locator_sha256","sha256":"1f666e80727c88baedf2477184041d5b340c5be7469754a84b9a9e23d07a0c82"},"content_fingerprint":null,"retrieval":null},{"id":"src_6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4","url":"https://static.csisolar.com/wp-content/uploads/2025/07/29095107/CS-Datasheet-Low-Carbon_HiHero-HJT_CS6.2-66HB_v1.5_EN_0.30-90%C2%B15.pdf","label":"Primary datasheet","source_type":"datasheet","source_type_basis":"authored_display_type_or_url_heuristic","publisher":null,"licence":{"status":"unresolved","name":null,"url":null,"attribution":null,"permissions":{"display":null,"cache":null,"redistribute":null,"derive":null,"ai_use":null}},"locator_fingerprint":{"kind":"locator_sha256","sha256":"6ef185b7ae94813fa36bdbdeab1bd0d1eeacf8164a8cbf8ef82eac7e756f9bd4"},"content_fingerprint":null,"retrieval":null},{"id":"src_7b8945c7fae51933a25b8f1c35d482e191ff4ad4e3313dec5cf77b167661aaa1","url":"https://www.csisolar.com/au/hihero/","label":"AU market evidence","source_type":"manufacturer","source_type_basis":"authored_display_type_or_url_heuristic","publisher":null,"licence":{"status":"unresolved","name":null,"url":null,"attribution":null,"permissions":{"display":null,"cache":null,"redistribute":null,"derive":null,"ai_use":null}},"locator_fingerprint":{"kind":"locator_sha256","sha256":"7b8945c7fae51933a25b8f1c35d482e191ff4ad4e3313dec5cf77b167661aaa1"},"content_fingerprint":null,"retrieval":null},{"id":"src_a9bfedb79d428298105fa3665d4f4d6ccad01cd610777d12d1a290dd60259173","url":"https://cleanenergycouncil.org.au/industry-programs/products-program","label":"PID (IEC TS 62804)","source_type":"manufacturer","source_type_basis":"authored_display_type_or_url_heuristic","publisher":null,"licence":{"status":"unresolved","name":null,"url":null,"attribution":null,"permissions":{"display":null,"cache":null,"redistribute":null,"derive":null,"ai_use":null}},"locator_fingerprint":{"kind":"locator_sha256","sha256":"a9bfedb79d428298105fa3665d4f4d6ccad01cd610777d12d1a290dd60259173"},"content_fingerprint":null,"retrieval":null},{"id":"src_cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60","url":"https://cleanenergycouncil.org.au/industry/products/modules","label":"PID (IEC TS 62804)","source_type":"manufacturer","source_type_basis":"authored_display_type_or_url_heuristic","publisher":null,"licence":{"status":"unresolved","name":null,"url":null,"attribution":null,"permissions":{"display":null,"cache":null,"redistribute":null,"derive":null,"ai_use":null}},"locator_fingerprint":{"kind":"locator_sha256","sha256":"cfabc5d756f36b51ed786885354acb90e1d05904cf2663fe31966abc394def60"},"content_fingerprint":null,"retrieval":null}],"boundaries":{"rights":"An unresolved licence field is not permission to cache, redistribute, derive from, or use a source for AI.","history":"Evidence events record verification activity. Change-history events separately record accepted before-and-after publication changes.","change_history":"Events record accepted publication changes, not every evidence re-check or a claim that the product changed on that date.","change_validity":"valid_from and valid_to remain null unless a source establishes when the changed fact applied in the world.","change_scope":"Compatibility, system pairing, suitability and relative leaderboard prose are excluded.","applicability":"Market evidence does not establish stock, system compatibility, network approval, installation suitability, or approval of an earlier installation.","approval_history":"Approval history contains exact, score-neutral source-register links recorded since monitoring began. It is not a complete lifetime history."}}