SH5.0/6.0RS
Sungrow
78/ 100
Strong evidence coverage · 100%
Evidence checked 2026-08-02
Available in Australia · checked 2026-08-02
Buyer evidence: Ready (100% direct coverage).
Compare like with like. Aligned scores, specifications and local evidence within one scoring class or tier.
Market context
Australia purchasing view
Sungrow
78/ 100
Strong evidence coverage · 100%
Evidence checked 2026-08-02
Available in Australia · checked 2026-08-02
Buyer evidence: Ready (100% direct coverage).
GoodWe
81/ 100
Strong evidence coverage · 100%
Evidence checked 2026-08-02
Available in Australia · checked 2026-08-02
Buyer evidence: Ready (100% direct coverage).
| Measure | SH5.0/6.0RS | ET G2 |
|---|---|---|
| Efficiency | ||
| Design & Flexibility | ||
| Thermal & Physical Resilience | ||
| Features & Integration | ||
| Safety & Compliance | ||
| Guarantee & Backbone | ||
| Energy Ecosystem |
| Measure | SH5.0/6.0RS | ET G2 |
|---|---|---|
| Published rated AC power range | 5–6 kW | 6–15 kW |
| Scored benchmark | 6 kW | 15 kW |
| Power | 6.0 kW | 15.0 kW |
| Type | Hybrid | Hybrid |
| Peak eff | 97.7 % | 98.2 % |
| MPPTs | 2 | 3 |
| Evidence | SH5.0/6.0RS | ET G2 |
|---|---|---|
| Outcome | Available in Australia | Available in Australia |
| Checked | 2026-08-02 | 2026-08-02 |
| Certifications | The Australian CEC approved-inverter export dated 22 July 2026 lists exact SH5.0RS and SH6.0RS Residential Hybrid models to AS/NZS 4777.2:2020 through 30 January 2028., The exact Australian datasheet lists IEC/EN 62109-1, IEC/EN 62109-2 and AS/NZS 4777.2:2020. | The Australian CEC approved-inverter export dated 22 July 2026 lists exact GW6000-ET-20, GW8000-ET-20, GW9900-ET-20, GW12K-ET-20 and GW15K-ET-20 models to AS/NZS 4777.2:2020 through 29 October 2027., The exact system manual lists IEC 62109-1/-2 and multiple national grid codes. |
| Warranty scope | Australia; Sungrow's 10-Year Standard Warranty Version 4.2 explicitly lists SH5.0RS and SH6.0RS for eligible units originally sold and installed in Australia. | Australia and New Zealand; GoodWe's current Rev 5.8 limited warranty explicitly places ET G2 under 10 years of cover for eligible products. |
| Warranty remedy | Repair or replacement at Sungrow's discretion for an approved claim. | Configuration change, repair or replacement at GoodWe's discretion. |
| Labour and reinstallation | The standard service rebate contributes to approved replacement labour. The service rebate contributes to replacement work but does not promise all site costs. | GoodWe may provide authorised on-site service or a conditional service rebate. On-site labour support is conditional and requires prior authorisation. |
| Freight | Standard ground freight is covered up to the published limit. | Normal ground transport is covered up to GoodWe's stated case limit. |
| Transfer and registration | Transfers for the remaining term when original purchase evidence is available. Optional parts-only or standard-warranty extensions are governed by the published extension terms. | No express subsequent-owner transfer right was found in the governing terms. The standard ET G2 term is listed as 10 years; claim and monitoring conditions in the governing terms still apply. |
| Grid compatibility | Single-phase 230 V hybrid family with exact-model Australian CEC listings. DNSP settings, export limits and battery compatibility remain installation-specific. | Three-phase 380/400 V hybrid family with exact-model CEC listings. DNSP acceptance, export settings, battery pairing and backup design remain installation-specific. |
| System fit | 2 confirmed pairings | Confirmed: GoodWe Lynx Home F G2 |
| Local product pathway | No separate local pathway recorded | No separate local pathway recorded |
| Buyer evidence | Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed. | Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed. |
| Safety notice | No model-specific notice recorded | No model-specific notice recorded |
| Review note | The 6 kW SH6.0RS is the scored series benchmark. CEC listings are dynamic and should be rechecked before installation. | The 15 kW GW15K-ET-20 is the scored series benchmark. CEC listings are dynamic and should be checked before installation. |
| Sources | Source 1Source 2Source 3Source 4Source 5 | Source 1Source 2Source 3Source 4Source 5 |
These checks sit beside the benchmark score. They are site, tariff and contract questions that no product score can settle.
Ask for every model number to appear on the quote and order. The Clean Energy Council product lists are live: STC creation requires listed products at installation, and network requirements may also depend on current approval.
Have the retailer state the supply phase, inverter connection limit, export limit and any export-control cost. The local network connection agreement, not a generic datasheet, determines those settings. See the Australian Government's connection guidance.
Ask which bills or interval data, tariff, feed-in rate, export limit and future loads support the savings and payback claim. Self-consumed electricity and tariff timing usually matter more than a headline feed-in rate. See the system sizing and battery savings guidance.
Confirm the proposed inverter phase, PV input design, battery pairing and export-control configuration against the final connection agreement. A suitable product can still require a different site design or control setting.
Keep the retailer, installer, manufacturer warranty and escalation path in the contract. Australian Consumer Law guarantees apply separately from any manufacturer warranty; where one business supplied both product and installation, it is generally responsible for the remedy. See the ACCC guidance.
A score lead is only meaningful inside this shared class or tier. Weigh it against the specification and evidence rows above before deciding.
Both products are scored in the Inverter class, on the same rubric weighting. Scores are not comparable across classes or tiers. Full methodology.