| Outcome | Available in Australia | Available in Australia |
|---|
| Checked | 2026-08-06 | 2026-08-29 |
|---|
| Certifications | BAT-634 and EESS-240878-1 list Cygni M2 through M4 configurations, approved 14 July 2025 and expiring 31 December 2027., BAT-692 and EESS-240878-2 list Cygni M6 through M12 configurations, approved 15 October 2025 and expiring 31 December 2027. | The exact BAT-10.1P datasheet lists IEC 62619, IEC 63056, IEC 62040 and UN 38.3; the SMILE-G3-S5 AU system datasheet lists AS 4777.2 and IEC 62109. |
|---|
| Warranty scope | Australia-labelled V2-2025, still linked in the AU download centre and reviewed 4 October 2026, names Cygni 10.0HS-M4. Dyness Digital Energy Technology Co., Ltd administers the warranty; Dyness Aus Pty Ltd is the importer/local service route. Start is earlier of first completed installation or Dyness shipment plus 180 days. Battery/inverter ten years; meter three, Wi-Fi five, LCD two years; accessories/toolkit excluded. Used without communications reduces the term to three years; exact link/cloud/outage requirements are unestablished. M4 performance gate is 70% usable energy until ten years or 45.271 MWh output throughput, whichever first, under the prescribed use/test conditions. | Australia; the 11 October 2024 warranty names SMILE-G3-S5 and BAT-10.1P with a ten-year term, 70% retained capacity and a 3.12 MWh/kWh throughput condition for eligible installations from 1 November 2024. |
|---|
| Warranty remedy | Repair/replacement of accepted defective product; replacement retains the original remaining term without renewal. Jointly approved disputed testing is initially buyer-paid, with testing and transport reimbursed if the claim proves within warranty. Unconditional site labour/removal/reinstallation costs remain unestablished. The policy preserves Australian Consumer Law rights. | Repair or replacement at AlphaESS's option. |
|---|
| Labour and reinstallation | Unconditional full-term site labour coverage was not established and is not credited. Unconditional removal and reinstallation coverage was not established and is not credited. | Clause 2 excludes travelling and accommodation costs of persons for on-site support and does not name labour as covered or excluded. The warranty requires a qualified installer to be available for exchange and re-commissioning (clause 3) and obliges the original installer to assist with replacement (clause 10); reimbursement of necessary and reasonably incurred costs of a valid claim may be claimed with documentary evidence (clauses 2 and 10). Removal and reinstallation are not promised. |
|---|
| Freight | Conditional reimbursement of transport/testing expenses follows a valid jointly approved disputed test. This is not an unconditional full-term transport entitlement; outside-warranty costs are buyer-paid and original packaging requirements apply. | Replacement-parts freight is covered for an accepted claim. |
|---|
| Transfer and registration | An automatic transfer right was not established in the reviewed governing document. No mandatory initial app/web registration is established: unregistered owners use the supplied warranty card via email/dealer; registered owners use the app/web service route. Notify Dyness within 48 hours of discovering a defect; separate exclusion concerns failure not reported to seller/authorised service partner within two weeks. Provide purchase/serial/start-date/authorised defect evidence, logs and system/fault details. Without communications the term is three years; required link and outage tolerance remain unresolved. | The warranty is non-transferable except where the products remain installed in a building, in which case it transfers to a later purchaser of that building. Serial registration before a claim, and installation by an SAA-accredited installer with a valid Alpha Installer ID, are required. |
|---|
| Grid/network approval evidence | Single-phase integrated hybrid family with exact Australian approval entries. DNSP settings and export limits remain site-specific. | The exact AU system is a 5 kW, 230 V single-phase hybrid under AS 4777.2. Current project approval and installer eligibility remain installation-specific. |
|---|
| Local product pathway | No separate local pathway recorded | No separate local pathway recorded |
|---|
| Buyer evidence | Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed. | Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed. |
|---|
| Safety notice | No model-specific notice recorded | No model-specific notice recorded |
|---|
| Review note | Existing dated approval and product evidence retained. Warranty appendix requires coastal installation one kilometre from the coastline, altitude below 3000 m, ambient 0–50 C and no conductive dust/corrosive gas; these are warranty conditions, not new physical ratings. Relocation requires written Dyness confirmation. Required communications link and outage tolerance are not specified as continuous cloud access in the reviewed policy. | AlphaESS's current 2026 Australian brochure lists SMILE-G3-S5/B5 with both BAT-10.1P and BAT-9.3S. The battery options coexist; neither is presented as the formal successor to the other. |
|---|
| Register: parts term | Not in the structured register | Not in the structured register |
|---|
| Register: labour and service | Not in the structured register | Not in the structured register |
|---|
| Register: transport and freight | Not in the structured register | Not in the structured register |
|---|
| Register: registration | Not in the structured register | Not in the structured register |
|---|
| Register: transferability | Not in the structured register | Not in the structured register |
|---|
| Register: explicit unknowns | Not in the structured register | Not in the structured register |
|---|
| Latest reviewed Approval Watch event | No exact-identity event in reviewed history | No exact-identity event in reviewed history |
|---|
| Sources | Source 1Source 2Source 3Source 4Source 5Source 6 | Source 1Source 2Source 3Source 4Source 5Source 6 |
|---|