Decision evidence · 04 Environmental resilience

Panel durability

Separates exact-series environmental and reliability evidence from generic certification or brand-level claims.

28 product records413 criterion records

Buying question
Which stress tests, loads and independent observations explicitly include the exact module family?
Evidence boundary
Passing a qualification test does not predict every installation. Generic brand certificates are not assigned to a model unless their published scope includes it.

Evidence by product

Neostar 3P 54-cellAIKO · AU priority 19Published5Reviewed absence0Not applicable2Open
Hail resistancePublished
IEC 61215 standard (25mm)aikosolar.comaikosolar.com
PID (IEC TS 62804)Published
Claimed, no test citedaikosolar.com
Salt mist (IEC 61701)Published
Not Listedaikosolar.com
Ammonia resistance (IEC 62716)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedaikosolar.com
Fire classification (IEC 61730)Published
Certifiedaikosolar.comaikosolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400aikosolar.comaikosolar.com
Negative loading (MQT16, Pa)Published
2400aikosolar.comaikosolar.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedaikosolar.com
HailOpen
Current sheet: 25 mm at 23 m/s. Superseded AU sheet: 40 mm at 27.5 m/s. Keep the revision conflict visible. Scope: AIKO-A470-MCE54Mw to AIKO-A500-MCE54Mwaikosolar.comaikosolar.com
Salt mist and ammoniaPublished
IEC 61701 and IEC 62716 are listed. No severity, certificate number or result is published in the sheet. Scope: Exact familyaikosolar.com
Fire classificationPublished
IEC fire Class C. Scope: Exact familyaikosolar.com
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load. Installation method remains governing. Scope: Exact familyaikosolar.comaikosolar.com
Reviewed absenceReviewed absence
No exact PID result, extended damp-heat duration beyond baseline qualification, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familyaikosolar.comaikosolar.comaikosolar.com
Open the complete scorecard
Neostar 3S54 Full BlackAIKO · AU priority 14Published0Reviewed absence0Not applicable7Open
Hail resistancePublished
IEC 61215 standard (25mm)aikosolar.com
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Published
Certifiedaikosolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400aikosolar.com
Negative loading (MQT16, Pa)Published
2400aikosolar.com
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Open the complete scorecard
HeteroMax CE-BF(ZB) 48-cellHD Hyundai · AU priority 15Published1Reviewed absence0Not applicable8Open
Hail resistanceOpen
Not established
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Published
Certifiedstatic1.squarespace.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400static1.squarespace.com
Negative loading (MQT16, Pa)Published
2400static1.squarespace.com
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Fire classificationPublished
IEC fire Class C. Scope: Exact CE-BF(ZB) familystatic1.squarespace.com
Mechanical loadPublished
5400 Pa front and 2400 Pa rear maximum test load. Scope: Exact CE-BF(ZB) familystatic1.squarespace.com
Reviewed absenceReviewed absence
No exact enhanced hail result, PID report, IEC 61701 certificate/severity, IEC 62716 certificate, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familystatic1.squarespace.com
Open the complete scorecard
Neostar 3P+ 60-cellAIKO · AU priority 18Published7Reviewed absence0Not applicable1Open
Hail resistancePublished
Enhanced hail 35mm certifiedaikosolar.com
PID (IEC TS 62804)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedaikosolar.comaikosolar.com
Salt mist (IEC 61701)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedaikosolar.comaikosolar.com
Ammonia resistance (IEC 62716)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedaikosolar.com
Fire classification (IEC 61730)Published
Certifiedaikosolar.comaikosolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400aikosolar.comaikosolar.com
Negative loading (MQT16, Pa)Published
2400aikosolar.comaikosolar.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedaikosolar.com
HailPublished
35 mm at 27.2 m/s. Scope: Exact 530 W to 550 W familyaikosolar.com
Fire classificationPublished
IEC fire Class A. Scope: Exact familyaikosolar.com
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load. Scope: Exact familyaikosolar.com
Reliability qualificationPublished
MCS certificate scope explicitly includes AIKO-Axxx-MCE60Dw, 520 W to 570 W. This establishes certification scope, not enhanced stress-test performance. Scope: Wildcard includes scored modelaikosolar.com
Reviewed absenceReviewed absence
No exact PID result, salt-mist severity/certificate, ammonia certificate, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or enhanced independent reliability report was located. Scope: Exact familyaikosolar.comaikosolar.com
Open the complete scorecard
DeepBlue 5.0 162-cellJA Solar · AU priority 14Published0Reviewed absence0Not applicable7Open
Hail resistancePublished
IEC 61215 standard (25mm)cdn.enfsolar.com
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Published
Certifiedcdn.enfsolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400cdn.enfsolar.com
Negative loading (MQT16, Pa)Published
2400cdn.enfsolar.com
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Open the complete scorecard
Hyper-ion Pro 66-cellRisen · AU priority 27Published1Reviewed absence0Not applicable8Open
Hail resistanceOpen
Not established
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Open
Not established
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400risenenergy.com.au
Negative loading (MQT16, Pa)Published
2400risenenergy.com.au
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDPublished
Carbon footprint / corporate ESG stated (no EPD)risenenergy.com.au
Fire classificationPublished
UL fire Class C. Scope: Exact RSM132-8 familyen.risen.com
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load. Scope: Exact familyen.risen.com
EPD/carbon footprintPublished
EPD scope explicitly includes RSM132-8-xxxBHDG, 630 W to 745 W. Scope: Exact familyepd-global.com
Product carbon claimPublished
Australian product page publishes less than 376.5 kg CO2e/kWc. Keep separate from the EPD indicators and declared unit. Scope: Exact RSM132-8-720-745BHDG pagerisenenergy.com.au
Reviewed absenceReviewed absence
No exact enhanced hail result, PID report, IEC 61701 result, IEC 62716 result, extended damp heat, independent energy-yield result, or exact public enhanced-reliability report was located. Scope: Exact familyen.risen.comepd-global.comrisenenergy.com.au
Open the complete scorecard
Tiger Neo III 48QL6-DVJinko Solar · AU priority 210Published4Reviewed absence0Not applicable1Open
Hail resistancePublished
IEC 61215 standard (25mm)jinkosolar.com.au
PID (IEC TS 62804)Published
Independently tested / certifiedjinkosolar.com.au
Salt mist (IEC 61701)Published
Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
Ammonia resistance (IEC 62716)Published
IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
Fire classification (IEC 61730)Published
Certifiedjinkosolar.com.au
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
6000jinkosolar.com.au
Negative loading (MQT16, Pa)Published
4000jinkosolar.com.au
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedjinkosolar.com.au
PID, salt mist and ammoniaPublished
Exact AU sheet lists IEC 62804, IEC 61701 and IEC 62716 and claims enhanced PID resistance. No severity, certificate number or numeric result is printed. Scope: Exact familyjinkosolar.com.au
Fire classificationPublished
IEC fire Class C. Scope: Exact familyjinkosolar.com.au
Mechanical loadPublished
6000 Pa front and 4000 Pa rear maximum static test load. Scope: Exact familyjinkosolar.com.au
Reviewed absenceReviewed absence
No exact enhanced hail value, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Secondary certificate indexes were not accepted as primary evidence. Scope: Exact familyjinkosolar.com.au
Open the complete scorecard
Tiger Neo III 51QL6-DV 51-cellJinko Solar · AU priority 27Published0Reviewed absence0Not applicable4Open
Hail resistancePublished
IEC 61215 standard (25mm)jinkosolar.com.au
PID (IEC TS 62804)Published
Independently tested / certifiedcleanenergycouncil.org.au
Salt mist (IEC 61701)Published
Certified (IEC 61701), severity not publishedcleanenergycouncil.org.au
Ammonia resistance (IEC 62716)Published
IEC 62716 certifiedcleanenergycouncil.org.au
Fire classification (IEC 61730)Published
Certifiedjinkosolar.com.au
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400jinkosolar.com.au
Negative loading (MQT16, Pa)Published
2400jinkosolar.com.au
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Open the complete scorecard
Ultra T 2.0 108 half-cellSuntech · AU priority 24Published1Reviewed absence0Not applicable10Open
Hail resistanceOpen
Not established
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Published
Certifiedsuntech-power.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Open
Not established
Negative loading (MQT16, Pa)Open
Not established
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Salt mist and ammoniaPublished
IEC 61701 salt mist and IEC 62716 ammonia are listed for the exact wildcard family. No severity or certificate number is printed. Scope: STP495-515S-H54-Nkh+; same exact family, earlier bin rangesuntech-power.com
Fire classificationPublished
IEC 61730-2 and UL 790 fire Class C. Scope: Exact wildcard familysuntech-power.com
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load. Scope: Exact family including current 500 W to 520 W sheetsuntech-power.com
Reviewed absenceReviewed absence
No exact enhanced hail result, PID report, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familysuntech-power.comsuntech-power.com
Open the complete scorecard
Sable BTE-BG 48-cellSeraphim · AU priority 24Published2Reviewed absence0Not applicable9Open
Hail resistanceOpen
Not established
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Open
Not established
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400seraphim-energy.com
Negative loading (MQT16, Pa)Published
2400seraphim-energy.com
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Mechanical loadPublished
Up to 5400 Pa front and 2400 Pa rear for the stated BTE-BG clamp zone. Scope: Exact familyseraphim-energy.com
Reliability qualificationPublished
TUV SUD critical component report 704062310808, revision 06A1, explicitly covers SRP-xxx-BTE-BG, 440 W to 460 W. This is component/certification scope, not an enhanced durability result. Scope: Exact wildcard familyseraphim-energy.com
Fire qualificationReviewed absence
Installation material establishes IEC 61730 safety Class II, but no exact fire classification was located. Keep fire class unknown. Scope: Exact family manualseraphim-energy.com
Reviewed absenceReviewed absence
No exact enhanced hail result, PID report, IEC 61701 result, IEC 62716 result, fire class, extended damp heat, EPD/product carbon declaration, or independent energy-yield result was located. Scope: Exact familyseraphim-energy.comseraphim-energy.comseraphim-energy.com
Open the complete scorecard
Vertex S+ G3 78-cellTrina Solar · AU priority 37Published7Reviewed absence0Not applicable1Open
Hail resistancePublished
IEC 61215 standard (25mm)www-cdn.trinasolar.com
PID (IEC TS 62804)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
Salt mist (IEC 61701)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
Ammonia resistance (IEC 62716)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
Fire classification (IEC 61730)Published
Certifiedwww-cdn.trinasolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400www-cdn.trinasolar.com
Negative loading (MQT16, Pa)Published
4000www-cdn.trinasolar.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
HailPublished
Baseline IEC hail qualification only; no enhanced stone size or velocity is published. Scope: Exact G3 familywww-cdn.trinasolar.com
Fire classificationPublished
Fire safety Class C. Scope: Exact familywww-cdn.trinasolar.com
Mechanical loadPublished
Up to 5400 Pa front and 4000 Pa rear static test load. Scope: Exact familywww-cdn.trinasolar.com
Reviewed absenceReviewed absence
No exact PID result, IEC 61701 result, IEC 62716 result, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public model-and-BOM reliability report was located. Scope: Exact familywww-cdn.trinasolar.com
Open the complete scorecard
Quasar 108-cellPhono Solar · AU priority 38Published1Reviewed absence0Not applicable7Open
Hail resistancePublished
IEC 61215 standard (25mm)phonosolar.com.au
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Published
Certifiedphonosolar.com.au
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400phonosolar.com.au
Negative loading (MQT16, Pa)Published
2400phonosolar.com.au
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
HailPublished
25 mm at 80 km/h. Scope: Exact 475 W to 495 W familyphonosolar.com.au
Salt mistPublished
Manufacturer Australian product page publishes IEC 61701 Severity 6. Scope: Exact Quasar family and model code shown on pagephonosolar.com.au
Fire classificationPublished
IEC fire Class C. Scope: Exact familyphonosolar.com.au
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load. Product page also claims cyclone testing without publishing the report. Scope: Exact familyphonosolar.com.auphonosolar.com.au
Reviewed absenceReviewed absence
No exact PID result, IEC 62716 ammonia result, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familyphonosolar.com.auphonosolar.com.au
Open the complete scorecard
Vertex S+ NEG18R.25Trina Solar · AU priority 36Published8Reviewed absence0Not applicable1Open
Hail resistancePublished
IEC 61215 standard (25mm)static.trinasolar.com
PID (IEC TS 62804)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
Salt mist (IEC 61701)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
Ammonia resistance (IEC 62716)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
Fire classification (IEC 61730)Published
Certifiedstatic.trinasolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400static.trinasolar.com
Negative loading (MQT16, Pa)Published
2400static.trinasolar.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comstatic.trinasolar.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comstatic.trinasolar.com
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
Salt mist and ammoniaPublished
IEC 61701 and IEC 62716 are listed for the exact family. No severity or certificate number is published in the sheet. Scope: Exact NEG18R.25 familywww-cdn.trinasolar.com
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load. Scope: Exact familystatic.trinasolar.com
Fire classificationReviewed absence
Product literature says strong fire performance but does not publish a class in the reviewed exact sheets. Keep the class unknown. Scope: Exact familywww-cdn.trinasolar.comstatic.trinasolar.com
Reviewed absenceReviewed absence
No exact enhanced hail result, PID report, fire class, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or public PVEL model-and-BOM/PAN file was located. Brand-level PVEL references are insufficient. Scope: Exact familywww-cdn.trinasolar.comstatic.trinasolar.com
Open the complete scorecard
Silhouette BRB3 48-cellSolahart · AU priority 39Published1Reviewed absence0Not applicable5Open
Hail resistanceOpen
Not established
PID (IEC TS 62804)Published
Independently tested / certifiedcleanenergycouncil.org.au
Salt mist (IEC 61701)Published
Certified (IEC 61701), severity not publishedcleanenergycouncil.org.au
Ammonia resistance (IEC 62716)Published
IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
Fire classification (IEC 61730)Published
Certifiedrheemaustralia.widen.net
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400rheemaustralia.widen.net
Negative loading (MQT16, Pa)Published
2400rheemaustralia.widen.net
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
PID, salt mist and ammoniaPublished
Australian approved-module listing identifies enhanced PID, IEC 61701 salt mist and IEC 62716 ammonia for the exact model. The public listing does not publish the PID conditions or salt severity. Scope: Exact SOLAHART455BRB3cer.gov.au
Fire classificationPublished
UL 790 Class A. Scope: Exact modelrheemaustralia.widen.net
Mechanical loadPublished
3600 Pa front and 1600 Pa rear design load; 5400 Pa front and 2400 Pa rear test load. Scope: Exact modelrheemaustralia.widen.net
Reviewed absenceReviewed absence
No enhanced hail result beyond baseline qualification, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public enhanced-reliability report was located. Scope: Exact modelcer.gov.aurheemaustralia.widen.net
Open the complete scorecard
DeepBlue 4.0 Pro 54D40 LR/AUJA Solar · AU priority 34Published0Reviewed absence0Not applicable7Open
Hail resistancePublished
IEC 61215 standard (25mm)jasolar.com
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Published
Certifiedjasolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400jasolar.com
Negative loading (MQT16, Pa)Published
2400jasolar.com
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Open the complete scorecard
Alpha Pure-RX 44-cellREC · AU priority 412Published3Reviewed absence0Not applicable2Open
Hail resistancePublished
Enhanced hail 45mm+ (Class 4 / Hail Proof certified)recgroup.com
PID (IEC TS 62804)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedrecgroup.com
Salt mist (IEC 61701)Published
Not Listedrecgroup.com
Ammonia resistance (IEC 62716)Published
Not listedrecgroup.com
Fire classification (IEC 61730)Published
Certifiedrecgroup.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
7000recgroup.com
Negative loading (MQT16, Pa)Published
4000recgroup.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityPublished
Tested - passrecgroup.com
Carbon footprint / EPDPublished
EPD published (intensity disclosed, not low-carbon certified)recgroup.com
HailPublished
Kiwa PVEL Hail Stress Sequence result: 55 mm at 33.9 m/s. Baseline IEC result: 35 mm. Scope: Exact Pure-RX family, including REC475AArecgroup.com
Salt mist and ammoniaOpen
IEC 61701 Severity 6 and IEC 62716 are marked optional. Do not treat them as installed-configuration evidence. Scope: Exact family, optional onlyrecgroup.com
Fire classificationPublished
IEC Class C; EN 13501 Class E and BROOF T2 also published. Scope: Exact familyrecgroup.com
Mechanical loadPublished
Four-point mounting: +7000/-4000 Pa test load. Six-point mounting: +10000/-6000 Pa internal test. Keep the independent and internal bases distinct. Scope: Exact familyrecgroup.com
EPD/carbon footprintPublished
Product EPD is specific to Alpha Pure-RX. Scope: Exact familyrecgroup.com
Reviewed absenceReviewed absence
No exact PID result, extended damp heat, independent field energy-yield result, or public PAN/model-and-BOM reliability file was located. Scope: Exact familyrecgroup.comrecgroup.com
Open the complete scorecard
Vertex S+ NEG9R.28 72-cellTrina Solar · AU priority 46Published1Reviewed absence0Not applicable4Open
Hail resistancePublished
IEC 61215 standard (25mm)static.trinasolar.com
PID (IEC TS 62804)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.comstatic.trinasolar.com
Salt mist (IEC 61701)Published
Not Listedstatic.trinasolar.com
Ammonia resistance (IEC 62716)Published
Not listedstatic.trinasolar.com
Fire classification (IEC 61730)Published
Certifiedstatic.trinasolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400static.trinasolar.com
Negative loading (MQT16, Pa)Published
4000static.trinasolar.com
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Open the complete scorecard
ASTRO N7s 2.0 48-cellAstronergy · AU priority 49Published1Reviewed absence0Not applicable5Open
Hail resistanceOpen
Not established
PID (IEC TS 62804)Published
Independently tested / certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
Salt mist (IEC 61701)Published
Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
Ammonia resistance (IEC 62716)Published
IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
Fire classification (IEC 61730)Published
Certifiedastronergy.com.au
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400astronergy.com.au
Negative loading (MQT16, Pa)Published
2400astronergy.com.au
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Mechanical loadPublished
6000 Pa front and 4000 Pa rear mechanical test load. Scope: Exact CHSM48RN(DG)/F-BH familyastronergy.com
Fire classificationPublished
IEC 61730 fire Class C for dual-glass modules. Scope: Installation manual includes exact familyastronergy.com
EPD/carbon footprintPublished
Product EPD explicitly includes CHSM48RN(DG)/F-BH. Scope: Exact family in declared product scopeepd-global.com
Reviewed absenceReviewed absence
No exact enhanced hail value, PID report, IEC 61701 result, IEC 62716 result, extended damp heat, independent energy-yield result, or exact public reliability report was located. Scope: Exact familyastronergy.comastronergy.comepd-global.com
Open the complete scorecard
Hi-MO X10 Scientist LR7-54HVHLONGi · AU priority 47Published7Reviewed absence0Not applicable2Open
Hail resistancePublished
IEC 61215 standard (25mm)static.longi.com
PID (IEC TS 62804)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
Salt mist (IEC 61701)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
Ammonia resistance (IEC 62716)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
Fire classification (IEC 61730)Published
Certifiedstatic.longi.comstatic.longi.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400static.longi.comstatic.longi.com
Negative loading (MQT16, Pa)Published
2400static.longi.comstatic.longi.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comstatic.longi.com
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
HailPublished
25 mm baseline hail rating. Scope: Exact LR7-54HVH familystatic.longi.com
Fire classificationPublished
IEC fire Class C. Scope: Exact familystatic.longi.com
Mechanical loadPublished
5400 Pa front and 2400 Pa rear maximum static load. Scope: Exact familystatic.longi.com
Reliability qualificationOpen
LONGi publishes family-level Hi-MO X10 claims for damp heat, UV and thermal cycling but no exact test conditions or report for LR7-54HVH. Do not score them as exact results. Scope: Product platform, not exact model reportlongi.com
Reviewed absenceReviewed absence
No exact PID result, IEC 61701 result, IEC 62716 result, extended damp-heat duration, EPD/product carbon declaration, independent energy-yield result, or public exact-model-and-BOM reliability report was located. The Hi-MO X10 lightweight report is a different product. Scope: Exact familystatic.longi.comlongi.com
Open the complete scorecard
Hi-MO 9 72HYDLONGi · AU priority 510Published5Reviewed absence0Not applicable1Open
Hail resistancePublished
IEC 61215 standard (25mm)static.longi.com
PID (IEC TS 62804)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
Salt mist (IEC 61701)Published
Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
Ammonia resistance (IEC 62716)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
Fire classification (IEC 61730)Published
Certifiedstatic.longi.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400static.longi.com
Negative loading (MQT16, Pa)Published
2400static.longi.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Carbon footprint / EPDPublished
EPD verified, <400 kg CO₂/kWp (certified low-carbon manufacturing)epd-global.no
HailPublished
25 mm at 23 m/s. Scope: Exact LR7-72HYD familystatic.longi.com
Fire classificationPublished
IEC fire Class C and UL Type 29. Scope: Exact familystatic.longi.com
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load, subject to mounting method. Scope: Exact familystatic.longi.com
EPD/carbon footprintPublished
EPD explicitly includes LR7-72HYD 625 W to 660 W, with 660 W as the representative product. A1-A3 is 346 kg CO2e/kWp. Scope: Exact familyepd-global.no
Reviewed absenceReviewed absence
No exact PID result, IEC 61701 result, IEC 62716 result, extended damp heat beyond baseline, independent energy-yield result, or public exact-model-and-BOM reliability report was located. Scope: Exact familystatic.longi.comepd-global.no
Open the complete scorecard
Infinity RT B54HBT 54-cellDMEGC Solar · AU priority 56Published0Reviewed absence0Not applicable5Open
Hail resistancePublished
Enhanced hail 28–34mm certifieddmegcsolar.com
PID (IEC TS 62804)Published
Claimed, no test citeddmegcsolar.com
Salt mist (IEC 61701)Published
Not Listeddmegcsolar.com
Ammonia resistance (IEC 62716)Published
IEC 62716 certifieddmegcsolar.com
Fire classification (IEC 61730)Open
Not established
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400dmegcsolar.com
Negative loading (MQT16, Pa)Published
2400dmegcsolar.com
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Open the complete scorecard
TOPHiKu6 48TDCanadian Solar · AU priority 611Published4Reviewed absence0Not applicable2Open
Hail resistancePublished
IEC 61215 standard (25mm)static.csisolar.com
PID (IEC TS 62804)Published
Not addressedstatic.csisolar.com
Salt mist (IEC 61701)Published
Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
Ammonia resistance (IEC 62716)Published
IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
Fire classification (IEC 61730)Published
Certifiedstatic.csisolar.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400static.csisolar.comstatic.csisolar.com
Negative loading (MQT16, Pa)Published
2400static.csisolar.comstatic.csisolar.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedstatic.csisolar.com
HailPublished
Manufacturer brochure claims hail resistance up to 35 mm. Scope: Exact CS6.2-48TD familystatic.csisolar.com
PIDPublished
Manufacturer brochure claims anti-PID performance. No numeric result or exact certificate is linked. Scope: Exact familystatic.csisolar.com
Salt mist and ammoniaOpen
IEC 61701 and IEC 62716 appear in the AU sheet, but its footnote says not all listed certifications apply to every module and instructs buyers to confirm the specific certificate. Keep both unconfirmed. Scope: Exact family sheet; applicability not establishedstatic.csisolar.com
Fire classificationPublished
IEC fire Class C and UL Type 29. Scope: Exact familystatic.csisolar.com
Mechanical loadPublished
Brochure publishes internal static testing to +3000/-5000 Pa and refers to third-party cyclone testing. Do not convert those figures to IEC design loads without the report. Scope: Exact familystatic.csisolar.com
Reviewed absenceReviewed absence
No exact extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public model-and-BOM reliability result was located. The HiHero HJT EPD is out of scope. Scope: Exact familystatic.csisolar.comstatic.csisolar.comstatic.csisolar.com
Open the complete scorecard
RSM108-11 54-cellRisen · AU priority 78Published4Reviewed absence0Not applicable2Open
Hail resistanceReviewed absence
Exact source reviewed; qualifying disclosure not publishedweb.archive.org
PID (IEC TS 62804)Published
Claimed, no test citedweb.archive.org
Salt mist (IEC 61701)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedweb.archive.org
Ammonia resistance (IEC 62716)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedweb.archive.org
Fire classification (IEC 61730)Open
Not established
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400web.archive.org
Negative loading (MQT16, Pa)Published
2400web.archive.org
Independent energy yieldPublished
Not independently yield-testedweb.archive.org
Verified reliabilityPublished
Not independently testedweb.archive.org
Carbon footprint / EPDPublished
Not publishedepd-global.comweb.archive.org
PIDPublished
Exact sheet makes an anti-PID claim but publishes no numeric result, certificate number or laboratory report. Scope: Exact 490 W to 515 W familyweb.archive.org
Mechanical loadPublished
5400 Pa front and 2400 Pa rear maximum mechanical test load under the stated installation method. Scope: Exact familyweb.archive.org
Reviewed absenceReviewed absence
No exact enhanced hail result, IEC 61701 result, IEC 62716 result, fire classification, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. The RSM132-11 EPD is a different family. Scope: Exact familyweb.archive.org
Open the complete scorecard
Alpha Pure-RREC · AU priority 811Published4Reviewed absence0Not applicable2Open
Hail resistancePublished
Enhanced hail 35mm certifiedrecgroup.com
PID (IEC TS 62804)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedrecgroup.com
Salt mist (IEC 61701)Published
Not Listedrecgroup.com
Ammonia resistance (IEC 62716)Published
Not listedrecgroup.com
Fire classification (IEC 61730)Published
Certifiedrecgroup.com
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
7000recgroup.com
Negative loading (MQT16, Pa)Published
4000recgroup.com
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Carbon footprint / EPDPublished
EPD published (intensity disclosed, not low-carbon certified)recgroup.com
HailPublished
35 mm hail resistance. Scope: Exact Pure-R familyrecgroup.com
Salt mist and ammoniaOpen
IEC 61701 Severity 6 and IEC 62716 are marked optional. Do not treat them as installed-configuration evidence. Scope: Exact family, optional onlyrecgroup.com
Fire classificationPublished
IEC fire Class C. Scope: Exact familyrecgroup.com
Reliability qualificationPublished
MCS certificate includes REC430AA Pure-R. This establishes exact certification scope, not enhanced reliability performance. Scope: Exact scored modelrecgroup.com
EPD/carbon footprintPublished
Product EPD is specific to Alpha Pure-R. Scope: Exact familyrecgroup.com
Reviewed absenceReviewed absence
No exact PID result, extended damp heat, independent energy-yield result, or public current model-and-BOM reliability result was located. Scope: Exact familyrecgroup.comrecgroup.comrecgroup.com
Open the complete scorecard
TWMNH-48HD 48-cellTW Solar · AU priority 96Published1Reviewed absence0Not applicable8Open
Hail resistanceOpen
Not established
PID (IEC TS 62804)Open
Not established
Salt mist (IEC 61701)Open
Not established
Ammonia resistance (IEC 62716)Open
Not established
Fire classification (IEC 61730)Published
Certifieden.tongwei.cn
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400en.tongwei.cn
Negative loading (MQT16, Pa)Published
2400en.tongwei.cn
Independent energy yieldOpen
Not established
Verified reliabilityOpen
Not established
Carbon footprint / EPDOpen
Not established
Fire classificationPublished
IEC fire Class C. Scope: Exact 440 W to 465 W familyen.tongwei.cn
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load. Scope: Exact familyen.tongwei.cn
EPD/carbon footprintPublished
Kiwa EPD explicitly includes TWMNH-48HD. Scope: Exact familykiwa.com
Reviewed absenceReviewed absence
No directly accessible exact primary certificate was located for enhanced hail, PID, IEC 61701, IEC 62716 or extended damp heat. No exact independent energy-yield or public model-and-BOM reliability result was located. Distributor certificate indexes were reviewed but not treated as evidence. Scope: Exact familyen.tongwei.cnkiwa.com
Open the complete scorecard
Walara G4PTindo Solar · AU priority 913Published3Reviewed absence0Not applicable1Open
Hail resistancePublished
IEC 61215 standard (25mm)tindosolar.com.au
PID (IEC TS 62804)Published
Independently tested / certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
Salt mist (IEC 61701)Reviewed absence
Exact source reviewed; qualifying disclosure not publishedtindosolar.com.au
Ammonia resistance (IEC 62716)Published
Not listedtindosolar.com.autindosolar.com.au
Fire classification (IEC 61730)Published
Certifiedtindosolar.com.au
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
5400tindosolar.com.au
Negative loading (MQT16, Pa)Published
2400tindosolar.com.au
Independent energy yieldPublished
Not independently yield-testedtindosolar.com.au
Verified reliabilityPublished
Not independently testedtindosolar.com.autindosolar.com.au
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedtindosolar.com.autindosolar.com.au
HailPublished
25 mm at 23 m/s. Scope: Exact Walara 440 G4Ptindosolar.com.au
PIDPublished
1500 VDC for 96 h at 85 C and 85% RH. The sheet does not name the laboratory or certificate. Scope: Exact modeltindosolar.com.au
Damp heat and thermal cyclingPublished
Damp heat: 1000 h at 85 C and 85% RH. Thermal cycling: 200 cycles. These are baseline-duration results, not extended qualification. Scope: Exact modeltindosolar.com.au
Fire classificationPublished
Fire Class C. Scope: Exact modeltindosolar.com.au
Mechanical loadPublished
5400 Pa front and 2400 Pa rear test load. Scope: Exact modeltindosolar.com.au
Reviewed absenceReviewed absence
No exact IEC 61701 salt result, IEC 62716 ammonia result, extended damp heat beyond 1000 h, EPD/product carbon declaration, independent current-model energy-yield result, or exact public enhanced-reliability report was located. DKA's Alice Springs array uses the older Karra 250, not G4P. Scope: Exact modeltindosolar.com.au
Open the complete scorecard
Tiger Neo 48HL4M-DBJinko Solar · AU priority 1111Published4Reviewed absence0Not applicable1Open
Hail resistancePublished
IEC 61215 standard (25mm)jinkosolar.eu
PID (IEC TS 62804)Published
Independently tested / certifiedjinkosolar.eu
Salt mist (IEC 61701)Published
Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
Ammonia resistance (IEC 62716)Published
IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
Fire classification (IEC 61730)Published
Certifiedjinkosolar.eu
Damp heat extended (2000h)Open
Not established
Positive loading (MQT16, Pa)Published
6000jinkosolar.eu
Negative loading (MQT16, Pa)Published
4000jinkosolar.eu
Independent energy yieldReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
Carbon footprint / EPDReviewed absence
Exact source reviewed; qualifying disclosure not publishedjinkosolar.eu
HailPublished
Baseline 25 mm hail statement. Scope: Exact 450 W to 475 W familyjinkosolar.eu
PID, salt mist and ammoniaPublished
Exact sheet lists IEC 62804, IEC 61701 and IEC 62716 and claims high salt-mist and ammonia resistance. No severity, certificate number or result is printed. Scope: Exact familyjinkosolar.eu
Fire classificationPublished
IEC fire Class C. Scope: Exact familyjinkosolar.eu
Mechanical loadPublished
6000 Pa front and 4000 Pa rear maximum static test load. Scope: Exact familyjinkosolar.eu
Reviewed absenceReviewed absence
No exact enhanced hail result beyond the published baseline, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or public exact-model reliability report was located. The broad Jinko EPD is not exact-series evidence. Scope: Exact familyjinkosolar.eu
Open the complete scorecard

Back to coverage across all five questions