- Buying question
- Which stress tests, loads and independent observations explicitly include the exact module family?
- Evidence boundary
- Passing a qualification test does not predict every installation. Generic brand certificates are not assigned to a model unless their published scope includes it.
Evidence by product
Each row counts, in order: published, reviewed absence, not applicable, open. What these mean
Neostar 3P54 Mono-GlassAIKO · AU priority 18Published4Reviewed absence0Not applicable2Open
- Hail resistanceOpen
- Current sheet: 25 mm at 23 m/s. Superseded AU sheet: 40 mm at 27.5 m/s. Keep the revision conflict visible. Scope: AIKO-A470-MCE54Mw to AIKO-A500-MCE54Mwaikosolar.comaikosolar.com
- PID (IEC TS 62804)Published
- Claimed, no test citedaikosolar.com
- Salt mist (IEC 61701)Published
- Not Listedaikosolar.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.com
- Fire classification (IEC 61730)Published
- IEC fire Class C. Scope: Exact familyaikosolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400aikosolar.comaikosolar.com
- Negative loading (MQT16, Pa)Published
- 2400aikosolar.comaikosolar.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredaikosolar.compv-magazine.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.com
- Salt mist and ammoniaPublished
- IEC 61701 and IEC 62716 are listed. No severity, certificate number or result is published in the sheet. Scope: Exact familyaikosolar.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Installation method remains governing. Scope: Exact familyaikosolar.comaikosolar.com
- Exact-family evidence gapsReviewed absence
- No exact PID result, extended damp-heat duration beyond baseline qualification, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familyaikosolar.comaikosolar.comaikosolar.com
Neostar 3P+ 60-cellAIKO · AU priority 17Published6Reviewed absence0Not applicable1Open
- Hail resistancePublished
- 35 mm at 27.2 m/s. Scope: Exact 530 W to 550 W familyaikosolar.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.comaikosolar.com
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.comaikosolar.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.com
- Fire classification (IEC 61730)Published
- IEC fire Class A. Scope: Exact familyaikosolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400aikosolar.comaikosolar.com
- Negative loading (MQT16, Pa)Published
- 2400aikosolar.comaikosolar.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredaikosolar.compv-magazine.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact familyaikosolar.com
- Reliability qualificationPublished
- MCS certificate scope explicitly includes AIKO-Axxx-MCE60Dw, 520 W to 570 W. This establishes certification scope, not enhanced stress-test performance. Scope: Wildcard includes scored modelaikosolar.com
- Exact-family evidence gapsReviewed absence
- No exact PID result, salt-mist severity/certificate, ammonia certificate, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or enhanced independent reliability report was located. Scope: Exact familyaikosolar.comaikosolar.com
Neostar 3S54 Full BlackAIKO · AU priority 15Published0Reviewed absence0Not applicable6Open
- Hail resistancePublished
- IEC 61215 standard (25mm)aikosolar.com
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedaikosolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400aikosolar.com
- Negative loading (MQT16, Pa)Published
- 2400aikosolar.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredaikosolar.compv-magazine.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
HeteroMax CE-BF(ZB) 48-cellHD Hyundai · AU priority 14Published2Reviewed absence0Not applicable7Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- IEC fire Class C. Scope: Exact CE-BF(ZB) familystatic1.squarespace.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static1.squarespace.com
- Negative loading (MQT16, Pa)Published
- 2400static1.squarespace.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear maximum test load. Scope: Exact CE-BF(ZB) familystatic1.squarespace.com
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail result, PID report, IEC 61701 certificate/severity, IEC 62716 certificate, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familystatic1.squarespace.com
Tiger Neo III 48-cell All-BlackJinko Solar · AU priority 16Published0Reviewed absence0Not applicable5Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.com.au
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.com.aucer.gov.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 6000jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 4000jinkosolar.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityPublished
- Brand or series independently tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDOpen
- Not established
Ultra T 3.0 48QGDF 48-cellSuntech · AU priority 12Published2Reviewed absence0Not applicable7Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400suntech-power.com
- Negative loading (MQT16, Pa)Published
- 2400suntech-power.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedsuntech-power.comsuntech-power.com
- Carbon footprint / EPDOpen
- Not established
DeepBlue 5.0 162-cellJA Solar · AU priority 14Published1Reviewed absence0Not applicable6Open
- Hail resistancePublished
- IEC 61215 standard (25mm)cdn.enfsolar.com
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedcdn.enfsolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400cdn.enfsolar.com
- Negative loading (MQT16, Pa)Published
- 2400cdn.enfsolar.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
LP182x210-M-48-NB 48-cellLeapton · AU priority 12Published3Reviewed absence0Not applicable6Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400leaptonenergy.au
- Negative loading (MQT16, Pa)Published
- 2400leaptonenergy.au
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedleaptonenergy.auleaptonenergy.au
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedleaptonenergy.au
Hyper-ion Pro 66-cellRisen · AU priority 27Published1Reviewed absence0Not applicable6Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- UL fire Class C. Scope: Exact RSM132-8 familyen.risen.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400risenenergy.com.au
- Negative loading (MQT16, Pa)Published
- 2400risenenergy.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDPublished
- EPD scope explicitly includes RSM132-8-xxxBHDG, 630 W to 745 W. The representative 745 W model reports A1-A3 GWP-total of 379 kg CO2e/kWp. Scope: Exact familyepd-global.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact familyen.risen.com
- Product carbon claimPublished
- Australian product page publishes less than 376.5 kg CO2e/kWc. Keep separate from the EPD indicators and declared unit. Scope: Exact RSM132-8-720-745BHDG pagerisenenergy.com.au
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail result, PID report, IEC 61701 result, IEC 62716 result, extended damp heat, independent energy-yield result, or exact public enhanced-reliability report was located. Scope: Exact familyen.risen.comepd-global.comrisenenergy.com.au
Tiger Neo III 48-cell Dual-GlassJinko Solar · AU priority 210Published3Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.com.au
- PID (IEC TS 62804)Published
- Independently tested / certifiedjinkosolar.com.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- IEC fire Class C. Scope: Exact familyjinkosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 6000jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 4000jinkosolar.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedjinkosolar.com.au
- PID, salt mist and ammoniaPublished
- Exact AU sheet lists IEC 62804, IEC 61701 and IEC 62716 and claims enhanced PID resistance. No severity, certificate number or numeric result is printed. Scope: Exact familyjinkosolar.com.au
- Mechanical loadPublished
- 6000 Pa front and 4000 Pa rear maximum static test load. Scope: Exact familyjinkosolar.com.au
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail value, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Secondary certificate indexes were not accepted as primary evidence. Scope: Exact familyjinkosolar.com.au
Tiger Neo III 51-cell Dual-GlassJinko Solar · AU priority 28Published0Reviewed absence0Not applicable3Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.com.au
- PID (IEC TS 62804)Published
- Independently tested / certifiedcleanenergycouncil.org.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400jinkosolar.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
Tiger Neo III 51-cell All-BlackJinko Solar · AU priority 26Published0Reviewed absence0Not applicable5Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.com.au
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.com.aucer.gov.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400jinkosolar.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityPublished
- Brand or series independently tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDOpen
- Not established
Ultra T 3.0 48QGSF 48-cellSuntech · AU priority 22Published2Reviewed absence0Not applicable7Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400suntech-power.com
- Negative loading (MQT16, Pa)Published
- 2400suntech-power.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedsuntech-power.comsuntech-power.com
- Carbon footprint / EPDOpen
- Not established
Sable BTE-BG 48-cellSeraphim · AU priority 25Published2Reviewed absence0Not applicable8Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400seraphim-energy.com
- Negative loading (MQT16, Pa)Published
- 2400seraphim-energy.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Mechanical loadPublished
- Up to 5400 Pa front and 2400 Pa rear for the stated BTE-BG clamp zone. Scope: Exact familyseraphim-energy.com
- Reliability qualificationPublished
- TUV SUD critical component report 704062310808, revision 06A1, explicitly covers SRP-xxx-BTE-BG, 440 W to 460 W. This is component/certification scope, not an enhanced durability result. Scope: Exact wildcard familyseraphim-energy.com
- Fire qualificationReviewed absence
- Installation material establishes IEC 61730 safety Class II, but no exact fire classification was located. Keep fire class unknown. Scope: Exact family manualseraphim-energy.com
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail result, PID report, IEC 61701 result, IEC 62716 result, fire class, extended damp heat, EPD/product carbon declaration, or independent energy-yield result was located. Scope: Exact familyseraphim-energy.comseraphim-energy.comseraphim-energy.com
Ultra T 2.0 108 half-cellSuntech · AU priority 23Published2Reviewed absence0Not applicable9Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- IEC 61730-2 and UL 790 fire Class C. Scope: Exact wildcard familysuntech-power.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Open
- Not established
- Negative loading (MQT16, Pa)Open
- Not established
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Salt mist and ammoniaPublished
- IEC 61701 salt mist and IEC 62716 ammonia are listed for the exact wildcard family. No severity or certificate number is printed. Scope: STP495-515S-H54-Nkh+; same exact family, earlier bin rangesuntech-power.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact family including current 500 W to 520 W sheetsuntech-power.com
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail result, PID report, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familysuntech-power.comsuntech-power.com
Vertex S+ G3 78-cell Dual-GlassTrina Solar · AU priority 36Published6Reviewed absence0Not applicable1Open
- Hail resistancePublished
- Baseline IEC hail qualification only; no enhanced stone size or velocity is published. Scope: Exact G3 familywww-cdn.trinasolar.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
- Fire classification (IEC 61730)Published
- Fire safety Class C. Scope: Exact familywww-cdn.trinasolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400www-cdn.trinasolar.com
- Negative loading (MQT16, Pa)Published
- 4000www-cdn.trinasolar.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
- Mechanical loadPublished
- Up to 5400 Pa front and 4000 Pa rear static test load. Scope: Exact familywww-cdn.trinasolar.com
- Exact-family evidence gapsReviewed absence
- No exact PID result, IEC 61701 result, IEC 62716 result, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public model-and-BOM reliability report was located. Scope: Exact familywww-cdn.trinasolar.com
Quasar 108-cellPhono Solar · AU priority 37Published1Reviewed absence0Not applicable5Open
- Hail resistancePublished
- 25 mm at 80 km/h. Scope: Exact 475 W to 495 W familyphonosolar.com.au
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Published
- Manufacturer Australian product page publishes IEC 61701 Severity 6. Scope: Exact Quasar family and model code shown on pagephonosolar.com.au
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- IEC fire Class C. Scope: Exact familyphonosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400phonosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400phonosolar.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Product page also claims cyclone testing without publishing the report. Scope: Exact familyphonosolar.com.auphonosolar.com.au
- Exact-family evidence gapsReviewed absence
- No exact PID result, IEC 62716 ammonia result, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familyphonosolar.com.auphonosolar.com.au
Vertex S+ NEG18R.25Trina Solar · AU priority 36Published7Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)static.trinasolar.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
- Fire classification (IEC 61730)Reviewed absence
- Product literature says strong fire performance but does not publish a class in the reviewed exact sheets. Keep the class unknown. Scope: Exact familywww-cdn.trinasolar.comstatic.trinasolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.trinasolar.com
- Negative loading (MQT16, Pa)Published
- 2400static.trinasolar.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comstatic.trinasolar.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
- Salt mist and ammoniaPublished
- IEC 61701 and IEC 62716 are listed for the exact family. No severity or certificate number is published in the sheet. Scope: Exact NEG18R.25 familywww-cdn.trinasolar.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact familystatic.trinasolar.com
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail result, PID report, fire class, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or public PVEL model-and-BOM/PAN file was located. Brand-level PVEL references are insufficient. Scope: Exact familywww-cdn.trinasolar.comstatic.trinasolar.com
Silhouette BRB3 48-cellSolahart · AU priority 38Published2Reviewed absence0Not applicable4Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Published
- Independently tested / certifiedcleanenergycouncil.org.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- UL 790 Class A. Scope: Exact modelrheemaustralia.widen.net
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400rheemaustralia.widen.net
- Negative loading (MQT16, Pa)Published
- 2400rheemaustralia.widen.net
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- PID, salt mist and ammoniaPublished
- Australian approved-module listing identifies enhanced PID, IEC 61701 salt mist and IEC 62716 ammonia for the exact model. The public listing does not publish the PID conditions or salt severity. Scope: Exact SOLAHART455BRB3cer.gov.au
- Mechanical loadPublished
- 3600 Pa front and 1600 Pa rear design load; 5400 Pa front and 2400 Pa rear test load. Scope: Exact modelrheemaustralia.widen.net
- Exact-family evidence gapsReviewed absence
- No enhanced hail result beyond baseline qualification, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public enhanced-reliability report was located. Scope: Exact modelcer.gov.aurheemaustralia.widen.net
DeepBlue 4.0 Pro 54D40 LR/AUJA Solar · AU priority 34Published1Reviewed absence0Not applicable6Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jasolar.com
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedjasolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400jasolar.com
- Negative loading (MQT16, Pa)Published
- 2400jasolar.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
DeepBlue 5.0 JAM48D50 48-cellJA Solar · AU priority 30Published2Reviewed absence0Not applicable9Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Open
- Not established
- Negative loading (MQT16, Pa)Open
- Not established
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedenfsolar.comcdn.enfsolar.com
- Carbon footprint / EPDOpen
- Not established
Alpha Pure-RX 44-cellREC · AU priority 49Published3Reviewed absence0Not applicable2Open
- Hail resistancePublished
- Kiwa PVEL Hail Stress Sequence result: 55 mm at 33.9 m/s. Baseline IEC result: 35 mm. Scope: Exact Pure-RX family, including REC475AArecgroup.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedrecgroup.com
- Salt mist (IEC 61701)Published
- Not Listedrecgroup.com
- Ammonia resistance (IEC 62716)Published
- Not listedrecgroup.com
- Fire classification (IEC 61730)Published
- IEC Class C; EN 13501 Class E and BROOF T2 also published. Scope: Exact familyrecgroup.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 7000recgroup.com
- Negative loading (MQT16, Pa)Published
- 4000recgroup.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityPublished
- Tested - passrecgroup.com
- Carbon footprint / EPDPublished
- Product EPD is specific to Alpha Pure-RX. Scope: Exact familyrecgroup.com
- Salt mist and ammoniaOpen
- IEC 61701 Severity 6 and IEC 62716 are marked optional. Do not treat them as installed-configuration evidence. Scope: Exact family, optional onlyrecgroup.com
- Mechanical loadPublished
- Four-point mounting: +7000/-4000 Pa test load. Six-point mounting: +10000/-6000 Pa internal test. Keep the independent and internal bases distinct. Scope: Exact familyrecgroup.com
- Exact-family evidence gapsReviewed absence
- No exact PID result, extended damp heat, independent field energy-yield result, or public PAN/model-and-BOM reliability file was located. Scope: Exact familyrecgroup.comrecgroup.com
Vertex S+ 72-cell Dual-GlassTrina Solar · AU priority 47Published1Reviewed absence0Not applicable3Open
- Hail resistancePublished
- IEC 61215 standard (25mm)static.trinasolar.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.comstatic.trinasolar.com
- Salt mist (IEC 61701)Published
- Not Listedstatic.trinasolar.com
- Ammonia resistance (IEC 62716)Published
- Not listedstatic.trinasolar.com
- Fire classification (IEC 61730)Published
- Certifiedstatic.trinasolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.trinasolar.com
- Negative loading (MQT16, Pa)Published
- 4000static.trinasolar.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
ASTRO N7s 2.0 48-cellAstronergy · AU priority 49Published1Reviewed absence0Not applicable3Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Published
- Independently tested / certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- IEC 61730 fire Class C for dual-glass modules. Scope: Installation manual includes exact familyastronergy.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400astronergy.com.au
- Negative loading (MQT16, Pa)Published
- 2400astronergy.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDPublished
- Product EPD explicitly includes CHSM48RN(DG)/F-BH. Scope: Exact family in declared product scopeepd-global.com
- Mechanical loadPublished
- 6000 Pa front and 4000 Pa rear mechanical test load. Scope: Exact CHSM48RN(DG)/F-BH familyastronergy.com
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail value, published salt-mist severity, extended damp heat, independent energy-yield result, or public exact-model-and-BOM reliability report was located. Scope: Exact familyastronergy.comastronergy.comepd-global.com
Hi-MO X10 Scientist 54-cellLONGi · AU priority 46Published6Reviewed absence0Not applicable2Open
- Hail resistancePublished
- 25 mm baseline hail rating. Scope: Exact LR7-54HVH familystatic.longi.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Fire classification (IEC 61730)Published
- IEC fire Class C. Scope: Exact familystatic.longi.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.longi.comstatic.longi.com
- Negative loading (MQT16, Pa)Published
- 2400static.longi.comstatic.longi.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comstatic.longi.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear maximum static load. Scope: Exact familystatic.longi.com
- Reliability qualificationOpen
- LONGi publishes family-level Hi-MO X10 claims for damp heat, UV and thermal cycling but no exact test conditions or report for LR7-54HVH. Do not score them as exact results. Scope: Product platform, not exact model reportlongi.com
- Exact-family evidence gapsReviewed absence
- No exact PID result, IEC 61701 result, IEC 62716 result, extended damp-heat duration, EPD/product carbon declaration, independent energy-yield result, or public exact-model-and-BOM reliability report was located. The Hi-MO X10 lightweight report is a different product. Scope: Exact familystatic.longi.comlongi.com
Hi-MO 9 72HYDLONGi · AU priority 58Published4Reviewed absence0Not applicable1Open
- Hail resistancePublished
- 25 mm at 23 m/s. Scope: Exact LR7-72HYD familystatic.longi.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Fire classification (IEC 61730)Published
- IEC fire Class C and UL Type 29. Scope: Exact familystatic.longi.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.longi.com
- Negative loading (MQT16, Pa)Published
- 2400static.longi.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDPublished
- EPD explicitly includes LR7-72HYD 625 W to 660 W, with 660 W as the representative product. A1-A3 is 346 kg CO2e/kWp. Scope: Exact familyepd-global.no
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load, subject to mounting method. Scope: Exact familystatic.longi.com
- Exact-family evidence gapsReviewed absence
- No exact PID result, published salt-mist severity, IEC 62716 result, extended damp heat beyond baseline, independent energy-yield result, or public exact-model-and-BOM reliability report was located. Scope: Exact familystatic.longi.comepd-global.no
Infinity RT B54HBT 54-cellDMEGC Solar · AU priority 57Published0Reviewed absence0Not applicable4Open
- Hail resistancePublished
- Enhanced hail 28–34mm certifieddmegcsolar.com
- PID (IEC TS 62804)Published
- Claimed, no test citeddmegcsolar.com
- Salt mist (IEC 61701)Published
- Not Listeddmegcsolar.com
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifieddmegcsolar.com
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400dmegcsolar.com
- Negative loading (MQT16, Pa)Published
- 2400dmegcsolar.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
TOPHiKu6 48TDCanadian Solar · AU priority 69Published3Reviewed absence0Not applicable2Open
- Hail resistancePublished
- Manufacturer brochure claims hail resistance up to 35 mm. Scope: Exact CS6.2-48TD familystatic.csisolar.com
- PID (IEC TS 62804)Published
- Manufacturer brochure claims anti-PID performance. No numeric result or exact certificate is linked. Scope: Exact familystatic.csisolar.com
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- IEC fire Class C and UL Type 29. Scope: Exact familystatic.csisolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.csisolar.comstatic.csisolar.com
- Negative loading (MQT16, Pa)Published
- 2400static.csisolar.comstatic.csisolar.com
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.csisolar.com
- Salt mist and ammoniaOpen
- IEC 61701 and IEC 62716 appear in the AU sheet, but its footnote says not all listed certifications apply to every module and instructs buyers to confirm the specific certificate. Keep both unconfirmed. Scope: Exact family sheet; applicability not establishedstatic.csisolar.com
- Mechanical loadPublished
- Brochure publishes internal static testing to +3000/-5000 Pa and refers to third-party cyclone testing. Do not convert those figures to IEC design loads without the report. Scope: Exact familystatic.csisolar.com
- Exact-family evidence gapsReviewed absence
- No exact extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public model-and-BOM reliability result was located. The HiHero HJT EPD is out of scope. Scope: Exact familystatic.csisolar.comstatic.csisolar.comstatic.csisolar.com
RSM108-11 54-cellRisen · AU priority 75Published6Reviewed absence0Not applicable2Open
- Hail resistanceReviewed absence
- Exact source reviewed; qualifying disclosure not publishedweb.archive.org
- PID (IEC TS 62804)Published
- Exact sheet makes an anti-PID claim but publishes no numeric result, certificate number or laboratory report. Scope: Exact 490 W to 515 W familyweb.archive.org
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedweb.archive.org
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedweb.archive.org
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400web.archive.org
- Negative loading (MQT16, Pa)Published
- 2400web.archive.org
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comweb.archive.org
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedepd-global.comweb.archive.org
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear maximum mechanical test load under the stated installation method. Scope: Exact familyweb.archive.org
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail result, IEC 61701 result, IEC 62716 result, fire classification, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. The RSM132-11 EPD is a different family. Scope: Exact familyweb.archive.org
Alpha Pure-RREC · AU priority 88Published4Reviewed absence0Not applicable2Open
- Hail resistancePublished
- 35 mm hail resistance. Scope: Exact Pure-R familyrecgroup.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedrecgroup.com
- Salt mist (IEC 61701)Published
- Not Listedrecgroup.com
- Ammonia resistance (IEC 62716)Published
- Not listedrecgroup.com
- Fire classification (IEC 61730)Published
- IEC fire Class C. Scope: Exact familyrecgroup.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 7000recgroup.com
- Negative loading (MQT16, Pa)Published
- 4000recgroup.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDPublished
- Product EPD is specific to Alpha Pure-R. Scope: Exact familyrecgroup.com
- Salt mist and ammoniaOpen
- IEC 61701 Severity 6 and IEC 62716 are marked optional. Do not treat them as installed-configuration evidence. Scope: Exact family, optional onlyrecgroup.com
- Reliability qualificationPublished
- MCS certificate includes REC430AA Pure-R. This establishes exact certification scope, not enhanced reliability performance. Scope: Exact scored modelrecgroup.com
- Exact-family evidence gapsReviewed absence
- No exact PID result, extended damp heat, independent energy-yield result, or public current model-and-BOM reliability result was located. Scope: Exact familyrecgroup.comrecgroup.comrecgroup.com
Tiger Neo 54HL4R-VJinko Solar · AU priority 99Published0Reviewed absence0Not applicable2Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Published
- Independently tested / certifiedjinkosolar.com.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedjinkosolar.com.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400jinkosolar.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityPublished
- Brand or series independently tested; exact model not coveredscorecard.pvel.com
- Carbon footprint / EPDPublished
- EPD verified, <400 kg CO₂/kWp (certified low-carbon manufacturing)epditaly.it
Walara G4PTindo Solar · AU priority 97Published6Reviewed absence0Not applicable1Open
- Hail resistancePublished
- 25 mm at 23 m/s. Scope: Exact Walara 440 G4Ptindosolar.com.au
- PID (IEC TS 62804)Published
- 1500 VDC for 96 h at 85 C and 85% RH. The sheet does not name the laboratory or certificate. Scope: Exact modeltindosolar.com.au
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedtindosolar.com.au
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedtindosolar.com.au
- Fire classification (IEC 61730)Published
- Fire Class C. Scope: Exact modeltindosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400tindosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400tindosolar.com.au
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comtindosolar.com.au
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedtindosolar.com.autindosolar.com.au
- Damp heat and thermal cyclingPublished
- Damp heat: 1000 h at 85 C and 85% RH. Thermal cycling: 200 cycles. These are baseline-duration results, not extended qualification. Scope: Exact modeltindosolar.com.au
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact modeltindosolar.com.au
- Exact-family evidence gapsReviewed absence
- No exact IEC 61701 salt result, IEC 62716 ammonia result, extended damp heat beyond 1000 h, EPD/product carbon declaration, independent current-model energy-yield result, or exact public enhanced-reliability report was located. DKA's Alice Springs array uses the older Karra 250, not G4P. Scope: Exact modeltindosolar.com.au
TWMNH-48HD 48-cellTW Solar · AU priority 96Published1Reviewed absence0Not applicable6Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- IEC fire Class C. Scope: Exact 440 W to 465 W familyen.tongwei.cn
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400en.tongwei.cn
- Negative loading (MQT16, Pa)Published
- 2400en.tongwei.cn
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDPublished
- Kiwa EPD explicitly includes TWMNH-48HD. Scope: Exact familykiwa.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact familyen.tongwei.cn
- Exact-family evidence gapsReviewed absence
- No directly accessible exact primary certificate was located for enhanced hail, PID, IEC 61701, IEC 62716 or extended damp heat. No exact independent energy-yield or public model-and-BOM reliability result was located. Distributor certificate indexes were reviewed but not treated as evidence. Scope: Exact familyen.tongwei.cnkiwa.com
NGX-D3 Dual-GlassWINAICO · AU priority 109Published3Reviewed absence0Not applicable1Open
- Hail resistancePublished
- Accredited Swiss Hail Register classification HW3, recognition 33074, valid to 2029. An exact manufacturer hail report is also public. Scope: Exact WST-NGX-D3 familyhagelregister.chwinaico.com
- PID (IEC TS 62804)Published
- Exact datasheet claims PID resistance but publishes no test condition, result or certificate number. Scope: Exact WST-450NGX-D3winaico.com.au
- Salt mist (IEC 61701)Published
- Exact-family IEC 61701 salt-mist certificate; manufacturer register identifies Severity 6. Scope: WST-NGX/NGXB-D3winaico.com
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certificate Z2 001256 0020 Rev01 covers WST-xxxNGX-D3, 445 W to 475 W. Scope: Exact wildcard includes scored modelwinaico.com
- Fire classification (IEC 61730)Published
- IEC 61730 fire Class C. Scope: Exact WST-450NGX-D3winaico.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400winaico.com.auwinaico.com
- Negative loading (MQT16, Pa)Published
- 2400winaico.com.auwinaico.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDPublished
- Product EPD includes WST-xxxNGX-D3 and WST-xxxNGXB-D3. Scope: Exact familywinaico.com
- Mechanical loadPublished
- For the manual's 2.0 mm glass and specified mounting configuration: design load 5400 Pa front and 2400 Pa rear; test load 8100 Pa front and 3600 Pa rear. The exact AU datasheet's general value is lower at 3600/1600 Pa design and 5400/2400 Pa test, so mounting and glass configuration must remain attached. Scope: WST-xxxNGX-D3, 400 W to 450 Wwinaico.comwinaico.com.au
- Exact-family evidence gapsReviewed absence
- No exact PID certificate/numeric result, extended damp heat, independent energy-yield result, or exact public model-and-BOM reliability report was located. Scope: Exact familyhagelregister.chwinaico.comwinaico.com.auwinaico.comwinaico.comwinaico.comwinaico.com
Tiger Neo 54HL4R-BJinko Solar · AU priority 1010Published0Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.com.au
- PID (IEC TS 62804)Published
- Independently tested / certifiedcleanenergycouncil.org.au
- Salt mist (IEC 61701)Published
- Severity 6jinkosolar.eu
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400jinkosolar.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityPublished
- Brand or series independently tested; exact model not coveredscorecard.pvel.com
- Carbon footprint / EPDPublished
- EPD verified, <400 kg CO₂/kWp (certified low-carbon manufacturing)epditaly.it
Tiger Neo 54HL4R-BDVJinko Solar · AU priority 118Published2Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.com.au
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedjinkosolar.com.au
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedjinkosolar.com.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400jinkosolar.com.au
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityPublished
- Brand or series independently tested; exact model not coveredscorecard.pvel.com
- Carbon footprint / EPDPublished
- EPD verified, <400 kg CO₂/kWp (certified low-carbon manufacturing)epditaly.it
Tiger Neo 48HL4M-DBJinko Solar · AU priority 1110Published3Reviewed absence0Not applicable1Open
- Hail resistancePublished
- Baseline 25 mm hail statement. Scope: Exact 450 W to 475 W familyjinkosolar.eu
- PID (IEC TS 62804)Published
- Independently tested / certifiedjinkosolar.eu
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- IEC fire Class C. Scope: Exact familyjinkosolar.eu
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 6000jinkosolar.eu
- Negative loading (MQT16, Pa)Published
- 4000jinkosolar.eu
- Independent energy yieldPublished
- Brand or series yield-tested; exact model not coveredscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedjinkosolar.eu
- PID, salt mist and ammoniaPublished
- Exact sheet lists IEC 62804, IEC 61701 and IEC 62716 and claims high salt-mist and ammonia resistance. No severity, certificate number or result is printed. Scope: Exact familyjinkosolar.eu
- Mechanical loadPublished
- 6000 Pa front and 4000 Pa rear maximum static test load. Scope: Exact familyjinkosolar.eu
- Exact-family evidence gapsReviewed absence
- No exact enhanced hail result beyond the published baseline, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or public exact-model reliability report was located. The broad Jinko EPD is not exact-series evidence. Scope: Exact familyjinkosolar.eu