28 product records413 criterion records
- Buying question
- Which stress tests, loads and independent observations explicitly include the exact module family?
- Evidence boundary
- Passing a qualification test does not predict every installation. Generic brand certificates are not assigned to a model unless their published scope includes it.
Evidence by product
Neostar 3P 54-cellAIKO · AU priority 19Published5Reviewed absence0Not applicable2Open
- Hail resistancePublished
- IEC 61215 standard (25mm)aikosolar.comaikosolar.com
- PID (IEC TS 62804)Published
- Claimed, no test citedaikosolar.com
- Salt mist (IEC 61701)Published
- Not Listedaikosolar.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.com
- Fire classification (IEC 61730)Published
- Certifiedaikosolar.comaikosolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400aikosolar.comaikosolar.com
- Negative loading (MQT16, Pa)Published
- 2400aikosolar.comaikosolar.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.com
- HailOpen
- Current sheet: 25 mm at 23 m/s. Superseded AU sheet: 40 mm at 27.5 m/s. Keep the revision conflict visible. Scope: AIKO-A470-MCE54Mw to AIKO-A500-MCE54Mwaikosolar.comaikosolar.com
- Salt mist and ammoniaPublished
- IEC 61701 and IEC 62716 are listed. No severity, certificate number or result is published in the sheet. Scope: Exact familyaikosolar.com
- Fire classificationPublished
- IEC fire Class C. Scope: Exact familyaikosolar.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Installation method remains governing. Scope: Exact familyaikosolar.comaikosolar.com
- Reviewed absenceReviewed absence
- No exact PID result, extended damp-heat duration beyond baseline qualification, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familyaikosolar.comaikosolar.comaikosolar.com
Neostar 3S54 Full BlackAIKO · AU priority 14Published0Reviewed absence0Not applicable7Open
- Hail resistancePublished
- IEC 61215 standard (25mm)aikosolar.com
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedaikosolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400aikosolar.com
- Negative loading (MQT16, Pa)Published
- 2400aikosolar.com
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
HeteroMax CE-BF(ZB) 48-cellHD Hyundai · AU priority 15Published1Reviewed absence0Not applicable8Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedstatic1.squarespace.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static1.squarespace.com
- Negative loading (MQT16, Pa)Published
- 2400static1.squarespace.com
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Fire classificationPublished
- IEC fire Class C. Scope: Exact CE-BF(ZB) familystatic1.squarespace.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear maximum test load. Scope: Exact CE-BF(ZB) familystatic1.squarespace.com
- Reviewed absenceReviewed absence
- No exact enhanced hail result, PID report, IEC 61701 certificate/severity, IEC 62716 certificate, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familystatic1.squarespace.com
Neostar 3P+ 60-cellAIKO · AU priority 18Published7Reviewed absence0Not applicable1Open
- Hail resistancePublished
- Enhanced hail 35mm certifiedaikosolar.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.comaikosolar.com
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.comaikosolar.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.com
- Fire classification (IEC 61730)Published
- Certifiedaikosolar.comaikosolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400aikosolar.comaikosolar.com
- Negative loading (MQT16, Pa)Published
- 2400aikosolar.comaikosolar.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedaikosolar.com
- HailPublished
- 35 mm at 27.2 m/s. Scope: Exact 530 W to 550 W familyaikosolar.com
- Fire classificationPublished
- IEC fire Class A. Scope: Exact familyaikosolar.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact familyaikosolar.com
- Reliability qualificationPublished
- MCS certificate scope explicitly includes AIKO-Axxx-MCE60Dw, 520 W to 570 W. This establishes certification scope, not enhanced stress-test performance. Scope: Wildcard includes scored modelaikosolar.com
- Reviewed absenceReviewed absence
- No exact PID result, salt-mist severity/certificate, ammonia certificate, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or enhanced independent reliability report was located. Scope: Exact familyaikosolar.comaikosolar.com
DeepBlue 5.0 162-cellJA Solar · AU priority 14Published0Reviewed absence0Not applicable7Open
- Hail resistancePublished
- IEC 61215 standard (25mm)cdn.enfsolar.com
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedcdn.enfsolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400cdn.enfsolar.com
- Negative loading (MQT16, Pa)Published
- 2400cdn.enfsolar.com
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
Hyper-ion Pro 66-cellRisen · AU priority 27Published1Reviewed absence0Not applicable8Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400risenenergy.com.au
- Negative loading (MQT16, Pa)Published
- 2400risenenergy.com.au
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDPublished
- Carbon footprint / corporate ESG stated (no EPD)risenenergy.com.au
- Fire classificationPublished
- UL fire Class C. Scope: Exact RSM132-8 familyen.risen.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact familyen.risen.com
- EPD/carbon footprintPublished
- EPD scope explicitly includes RSM132-8-xxxBHDG, 630 W to 745 W. Scope: Exact familyepd-global.com
- Product carbon claimPublished
- Australian product page publishes less than 376.5 kg CO2e/kWc. Keep separate from the EPD indicators and declared unit. Scope: Exact RSM132-8-720-745BHDG pagerisenenergy.com.au
- Reviewed absenceReviewed absence
- No exact enhanced hail result, PID report, IEC 61701 result, IEC 62716 result, extended damp heat, independent energy-yield result, or exact public enhanced-reliability report was located. Scope: Exact familyen.risen.comepd-global.comrisenenergy.com.au
Tiger Neo III 48QL6-DVJinko Solar · AU priority 210Published4Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.com.au
- PID (IEC TS 62804)Published
- Independently tested / certifiedjinkosolar.com.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 6000jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 4000jinkosolar.com.au
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedjinkosolar.com.au
- PID, salt mist and ammoniaPublished
- Exact AU sheet lists IEC 62804, IEC 61701 and IEC 62716 and claims enhanced PID resistance. No severity, certificate number or numeric result is printed. Scope: Exact familyjinkosolar.com.au
- Fire classificationPublished
- IEC fire Class C. Scope: Exact familyjinkosolar.com.au
- Mechanical loadPublished
- 6000 Pa front and 4000 Pa rear maximum static test load. Scope: Exact familyjinkosolar.com.au
- Reviewed absenceReviewed absence
- No exact enhanced hail value, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Secondary certificate indexes were not accepted as primary evidence. Scope: Exact familyjinkosolar.com.au
Tiger Neo III 51QL6-DV 51-cellJinko Solar · AU priority 27Published0Reviewed absence0Not applicable4Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.com.au
- PID (IEC TS 62804)Published
- Independently tested / certifiedcleanenergycouncil.org.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400jinkosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400jinkosolar.com.au
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
Ultra T 2.0 108 half-cellSuntech · AU priority 24Published1Reviewed absence0Not applicable10Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedsuntech-power.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Open
- Not established
- Negative loading (MQT16, Pa)Open
- Not established
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Salt mist and ammoniaPublished
- IEC 61701 salt mist and IEC 62716 ammonia are listed for the exact wildcard family. No severity or certificate number is printed. Scope: STP495-515S-H54-Nkh+; same exact family, earlier bin rangesuntech-power.com
- Fire classificationPublished
- IEC 61730-2 and UL 790 fire Class C. Scope: Exact wildcard familysuntech-power.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact family including current 500 W to 520 W sheetsuntech-power.com
- Reviewed absenceReviewed absence
- No exact enhanced hail result, PID report, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familysuntech-power.comsuntech-power.com
Sable BTE-BG 48-cellSeraphim · AU priority 24Published2Reviewed absence0Not applicable9Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400seraphim-energy.com
- Negative loading (MQT16, Pa)Published
- 2400seraphim-energy.com
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Mechanical loadPublished
- Up to 5400 Pa front and 2400 Pa rear for the stated BTE-BG clamp zone. Scope: Exact familyseraphim-energy.com
- Reliability qualificationPublished
- TUV SUD critical component report 704062310808, revision 06A1, explicitly covers SRP-xxx-BTE-BG, 440 W to 460 W. This is component/certification scope, not an enhanced durability result. Scope: Exact wildcard familyseraphim-energy.com
- Fire qualificationReviewed absence
- Installation material establishes IEC 61730 safety Class II, but no exact fire classification was located. Keep fire class unknown. Scope: Exact family manualseraphim-energy.com
- Reviewed absenceReviewed absence
- No exact enhanced hail result, PID report, IEC 61701 result, IEC 62716 result, fire class, extended damp heat, EPD/product carbon declaration, or independent energy-yield result was located. Scope: Exact familyseraphim-energy.comseraphim-energy.comseraphim-energy.com
Vertex S+ G3 78-cellTrina Solar · AU priority 37Published7Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)www-cdn.trinasolar.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
- Fire classification (IEC 61730)Published
- Certifiedwww-cdn.trinasolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400www-cdn.trinasolar.com
- Negative loading (MQT16, Pa)Published
- 4000www-cdn.trinasolar.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedwww-cdn.trinasolar.com
- HailPublished
- Baseline IEC hail qualification only; no enhanced stone size or velocity is published. Scope: Exact G3 familywww-cdn.trinasolar.com
- Fire classificationPublished
- Fire safety Class C. Scope: Exact familywww-cdn.trinasolar.com
- Mechanical loadPublished
- Up to 5400 Pa front and 4000 Pa rear static test load. Scope: Exact familywww-cdn.trinasolar.com
- Reviewed absenceReviewed absence
- No exact PID result, IEC 61701 result, IEC 62716 result, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public model-and-BOM reliability report was located. Scope: Exact familywww-cdn.trinasolar.com
Quasar 108-cellPhono Solar · AU priority 38Published1Reviewed absence0Not applicable7Open
- Hail resistancePublished
- IEC 61215 standard (25mm)phonosolar.com.au
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedphonosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400phonosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400phonosolar.com.au
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- HailPublished
- 25 mm at 80 km/h. Scope: Exact 475 W to 495 W familyphonosolar.com.au
- Salt mistPublished
- Manufacturer Australian product page publishes IEC 61701 Severity 6. Scope: Exact Quasar family and model code shown on pagephonosolar.com.au
- Fire classificationPublished
- IEC fire Class C. Scope: Exact familyphonosolar.com.au
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Product page also claims cyclone testing without publishing the report. Scope: Exact familyphonosolar.com.auphonosolar.com.au
- Reviewed absenceReviewed absence
- No exact PID result, IEC 62716 ammonia result, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. Scope: Exact familyphonosolar.com.auphonosolar.com.au
Vertex S+ NEG18R.25Trina Solar · AU priority 36Published8Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)static.trinasolar.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
- Fire classification (IEC 61730)Published
- Certifiedstatic.trinasolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.trinasolar.com
- Negative loading (MQT16, Pa)Published
- 2400static.trinasolar.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comstatic.trinasolar.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comstatic.trinasolar.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.com
- Salt mist and ammoniaPublished
- IEC 61701 and IEC 62716 are listed for the exact family. No severity or certificate number is published in the sheet. Scope: Exact NEG18R.25 familywww-cdn.trinasolar.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact familystatic.trinasolar.com
- Fire classificationReviewed absence
- Product literature says strong fire performance but does not publish a class in the reviewed exact sheets. Keep the class unknown. Scope: Exact familywww-cdn.trinasolar.comstatic.trinasolar.com
- Reviewed absenceReviewed absence
- No exact enhanced hail result, PID report, fire class, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or public PVEL model-and-BOM/PAN file was located. Brand-level PVEL references are insufficient. Scope: Exact familywww-cdn.trinasolar.comstatic.trinasolar.com
Silhouette BRB3 48-cellSolahart · AU priority 39Published1Reviewed absence0Not applicable5Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Published
- Independently tested / certifiedcleanenergycouncil.org.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedrheemaustralia.widen.net
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400rheemaustralia.widen.net
- Negative loading (MQT16, Pa)Published
- 2400rheemaustralia.widen.net
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- PID, salt mist and ammoniaPublished
- Australian approved-module listing identifies enhanced PID, IEC 61701 salt mist and IEC 62716 ammonia for the exact model. The public listing does not publish the PID conditions or salt severity. Scope: Exact SOLAHART455BRB3cer.gov.au
- Fire classificationPublished
- UL 790 Class A. Scope: Exact modelrheemaustralia.widen.net
- Mechanical loadPublished
- 3600 Pa front and 1600 Pa rear design load; 5400 Pa front and 2400 Pa rear test load. Scope: Exact modelrheemaustralia.widen.net
- Reviewed absenceReviewed absence
- No enhanced hail result beyond baseline qualification, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public enhanced-reliability report was located. Scope: Exact modelcer.gov.aurheemaustralia.widen.net
DeepBlue 4.0 Pro 54D40 LR/AUJA Solar · AU priority 34Published0Reviewed absence0Not applicable7Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jasolar.com
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifiedjasolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400jasolar.com
- Negative loading (MQT16, Pa)Published
- 2400jasolar.com
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
Alpha Pure-RX 44-cellREC · AU priority 412Published3Reviewed absence0Not applicable2Open
- Hail resistancePublished
- Enhanced hail 45mm+ (Class 4 / Hail Proof certified)recgroup.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedrecgroup.com
- Salt mist (IEC 61701)Published
- Not Listedrecgroup.com
- Ammonia resistance (IEC 62716)Published
- Not listedrecgroup.com
- Fire classification (IEC 61730)Published
- Certifiedrecgroup.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 7000recgroup.com
- Negative loading (MQT16, Pa)Published
- 4000recgroup.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityPublished
- Tested - passrecgroup.com
- Carbon footprint / EPDPublished
- EPD published (intensity disclosed, not low-carbon certified)recgroup.com
- HailPublished
- Kiwa PVEL Hail Stress Sequence result: 55 mm at 33.9 m/s. Baseline IEC result: 35 mm. Scope: Exact Pure-RX family, including REC475AArecgroup.com
- Salt mist and ammoniaOpen
- IEC 61701 Severity 6 and IEC 62716 are marked optional. Do not treat them as installed-configuration evidence. Scope: Exact family, optional onlyrecgroup.com
- Fire classificationPublished
- IEC Class C; EN 13501 Class E and BROOF T2 also published. Scope: Exact familyrecgroup.com
- Mechanical loadPublished
- Four-point mounting: +7000/-4000 Pa test load. Six-point mounting: +10000/-6000 Pa internal test. Keep the independent and internal bases distinct. Scope: Exact familyrecgroup.com
- EPD/carbon footprintPublished
- Product EPD is specific to Alpha Pure-RX. Scope: Exact familyrecgroup.com
- Reviewed absenceReviewed absence
- No exact PID result, extended damp heat, independent field energy-yield result, or public PAN/model-and-BOM reliability file was located. Scope: Exact familyrecgroup.comrecgroup.com
Vertex S+ NEG9R.28 72-cellTrina Solar · AU priority 46Published1Reviewed absence0Not applicable4Open
- Hail resistancePublished
- IEC 61215 standard (25mm)static.trinasolar.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.trinasolar.comstatic.trinasolar.com
- Salt mist (IEC 61701)Published
- Not Listedstatic.trinasolar.com
- Ammonia resistance (IEC 62716)Published
- Not listedstatic.trinasolar.com
- Fire classification (IEC 61730)Published
- Certifiedstatic.trinasolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.trinasolar.com
- Negative loading (MQT16, Pa)Published
- 4000static.trinasolar.com
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
ASTRO N7s 2.0 48-cellAstronergy · AU priority 49Published1Reviewed absence0Not applicable5Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Published
- Independently tested / certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedastronergy.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400astronergy.com.au
- Negative loading (MQT16, Pa)Published
- 2400astronergy.com.au
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Mechanical loadPublished
- 6000 Pa front and 4000 Pa rear mechanical test load. Scope: Exact CHSM48RN(DG)/F-BH familyastronergy.com
- Fire classificationPublished
- IEC 61730 fire Class C for dual-glass modules. Scope: Installation manual includes exact familyastronergy.com
- EPD/carbon footprintPublished
- Product EPD explicitly includes CHSM48RN(DG)/F-BH. Scope: Exact family in declared product scopeepd-global.com
- Reviewed absenceReviewed absence
- No exact enhanced hail value, PID report, IEC 61701 result, IEC 62716 result, extended damp heat, independent energy-yield result, or exact public reliability report was located. Scope: Exact familyastronergy.comastronergy.comepd-global.com
Hi-MO X10 Scientist LR7-54HVHLONGi · AU priority 47Published7Reviewed absence0Not applicable2Open
- Hail resistancePublished
- IEC 61215 standard (25mm)static.longi.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Fire classification (IEC 61730)Published
- Certifiedstatic.longi.comstatic.longi.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.longi.comstatic.longi.com
- Negative loading (MQT16, Pa)Published
- 2400static.longi.comstatic.longi.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.comstatic.longi.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- HailPublished
- 25 mm baseline hail rating. Scope: Exact LR7-54HVH familystatic.longi.com
- Fire classificationPublished
- IEC fire Class C. Scope: Exact familystatic.longi.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear maximum static load. Scope: Exact familystatic.longi.com
- Reliability qualificationOpen
- LONGi publishes family-level Hi-MO X10 claims for damp heat, UV and thermal cycling but no exact test conditions or report for LR7-54HVH. Do not score them as exact results. Scope: Product platform, not exact model reportlongi.com
- Reviewed absenceReviewed absence
- No exact PID result, IEC 61701 result, IEC 62716 result, extended damp-heat duration, EPD/product carbon declaration, independent energy-yield result, or public exact-model-and-BOM reliability report was located. The Hi-MO X10 lightweight report is a different product. Scope: Exact familystatic.longi.comlongi.com
Hi-MO 9 72HYDLONGi · AU priority 510Published5Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)static.longi.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.longi.com
- Fire classification (IEC 61730)Published
- Certifiedstatic.longi.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.longi.com
- Negative loading (MQT16, Pa)Published
- 2400static.longi.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDPublished
- EPD verified, <400 kg CO₂/kWp (certified low-carbon manufacturing)epd-global.no
- HailPublished
- 25 mm at 23 m/s. Scope: Exact LR7-72HYD familystatic.longi.com
- Fire classificationPublished
- IEC fire Class C and UL Type 29. Scope: Exact familystatic.longi.com
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load, subject to mounting method. Scope: Exact familystatic.longi.com
- EPD/carbon footprintPublished
- EPD explicitly includes LR7-72HYD 625 W to 660 W, with 660 W as the representative product. A1-A3 is 346 kg CO2e/kWp. Scope: Exact familyepd-global.no
- Reviewed absenceReviewed absence
- No exact PID result, IEC 61701 result, IEC 62716 result, extended damp heat beyond baseline, independent energy-yield result, or public exact-model-and-BOM reliability report was located. Scope: Exact familystatic.longi.comepd-global.no
Infinity RT B54HBT 54-cellDMEGC Solar · AU priority 56Published0Reviewed absence0Not applicable5Open
- Hail resistancePublished
- Enhanced hail 28–34mm certifieddmegcsolar.com
- PID (IEC TS 62804)Published
- Claimed, no test citeddmegcsolar.com
- Salt mist (IEC 61701)Published
- Not Listeddmegcsolar.com
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifieddmegcsolar.com
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400dmegcsolar.com
- Negative loading (MQT16, Pa)Published
- 2400dmegcsolar.com
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
TOPHiKu6 48TDCanadian Solar · AU priority 611Published4Reviewed absence0Not applicable2Open
- Hail resistancePublished
- IEC 61215 standard (25mm)static.csisolar.com
- PID (IEC TS 62804)Published
- Not addressedstatic.csisolar.com
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedstatic.csisolar.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400static.csisolar.comstatic.csisolar.com
- Negative loading (MQT16, Pa)Published
- 2400static.csisolar.comstatic.csisolar.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedstatic.csisolar.com
- HailPublished
- Manufacturer brochure claims hail resistance up to 35 mm. Scope: Exact CS6.2-48TD familystatic.csisolar.com
- PIDPublished
- Manufacturer brochure claims anti-PID performance. No numeric result or exact certificate is linked. Scope: Exact familystatic.csisolar.com
- Salt mist and ammoniaOpen
- IEC 61701 and IEC 62716 appear in the AU sheet, but its footnote says not all listed certifications apply to every module and instructs buyers to confirm the specific certificate. Keep both unconfirmed. Scope: Exact family sheet; applicability not establishedstatic.csisolar.com
- Fire classificationPublished
- IEC fire Class C and UL Type 29. Scope: Exact familystatic.csisolar.com
- Mechanical loadPublished
- Brochure publishes internal static testing to +3000/-5000 Pa and refers to third-party cyclone testing. Do not convert those figures to IEC design loads without the report. Scope: Exact familystatic.csisolar.com
- Reviewed absenceReviewed absence
- No exact extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public model-and-BOM reliability result was located. The HiHero HJT EPD is out of scope. Scope: Exact familystatic.csisolar.comstatic.csisolar.comstatic.csisolar.com
RSM108-11 54-cellRisen · AU priority 78Published4Reviewed absence0Not applicable2Open
- Hail resistanceReviewed absence
- Exact source reviewed; qualifying disclosure not publishedweb.archive.org
- PID (IEC TS 62804)Published
- Claimed, no test citedweb.archive.org
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedweb.archive.org
- Ammonia resistance (IEC 62716)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedweb.archive.org
- Fire classification (IEC 61730)Open
- Not established
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400web.archive.org
- Negative loading (MQT16, Pa)Published
- 2400web.archive.org
- Independent energy yieldPublished
- Not independently yield-testedweb.archive.org
- Verified reliabilityPublished
- Not independently testedweb.archive.org
- Carbon footprint / EPDPublished
- Not publishedepd-global.comweb.archive.org
- PIDPublished
- Exact sheet makes an anti-PID claim but publishes no numeric result, certificate number or laboratory report. Scope: Exact 490 W to 515 W familyweb.archive.org
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear maximum mechanical test load under the stated installation method. Scope: Exact familyweb.archive.org
- Reviewed absenceReviewed absence
- No exact enhanced hail result, IEC 61701 result, IEC 62716 result, fire classification, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or exact public reliability report was located. The RSM132-11 EPD is a different family. Scope: Exact familyweb.archive.org
Alpha Pure-RREC · AU priority 811Published4Reviewed absence0Not applicable2Open
- Hail resistancePublished
- Enhanced hail 35mm certifiedrecgroup.com
- PID (IEC TS 62804)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedrecgroup.com
- Salt mist (IEC 61701)Published
- Not Listedrecgroup.com
- Ammonia resistance (IEC 62716)Published
- Not listedrecgroup.com
- Fire classification (IEC 61730)Published
- Certifiedrecgroup.com
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 7000recgroup.com
- Negative loading (MQT16, Pa)Published
- 4000recgroup.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDPublished
- EPD published (intensity disclosed, not low-carbon certified)recgroup.com
- HailPublished
- 35 mm hail resistance. Scope: Exact Pure-R familyrecgroup.com
- Salt mist and ammoniaOpen
- IEC 61701 Severity 6 and IEC 62716 are marked optional. Do not treat them as installed-configuration evidence. Scope: Exact family, optional onlyrecgroup.com
- Fire classificationPublished
- IEC fire Class C. Scope: Exact familyrecgroup.com
- Reliability qualificationPublished
- MCS certificate includes REC430AA Pure-R. This establishes exact certification scope, not enhanced reliability performance. Scope: Exact scored modelrecgroup.com
- EPD/carbon footprintPublished
- Product EPD is specific to Alpha Pure-R. Scope: Exact familyrecgroup.com
- Reviewed absenceReviewed absence
- No exact PID result, extended damp heat, independent energy-yield result, or public current model-and-BOM reliability result was located. Scope: Exact familyrecgroup.comrecgroup.comrecgroup.com
TWMNH-48HD 48-cellTW Solar · AU priority 96Published1Reviewed absence0Not applicable8Open
- Hail resistanceOpen
- Not established
- PID (IEC TS 62804)Open
- Not established
- Salt mist (IEC 61701)Open
- Not established
- Ammonia resistance (IEC 62716)Open
- Not established
- Fire classification (IEC 61730)Published
- Certifieden.tongwei.cn
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400en.tongwei.cn
- Negative loading (MQT16, Pa)Published
- 2400en.tongwei.cn
- Independent energy yieldOpen
- Not established
- Verified reliabilityOpen
- Not established
- Carbon footprint / EPDOpen
- Not established
- Fire classificationPublished
- IEC fire Class C. Scope: Exact 440 W to 465 W familyen.tongwei.cn
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact familyen.tongwei.cn
- EPD/carbon footprintPublished
- Kiwa EPD explicitly includes TWMNH-48HD. Scope: Exact familykiwa.com
- Reviewed absenceReviewed absence
- No directly accessible exact primary certificate was located for enhanced hail, PID, IEC 61701, IEC 62716 or extended damp heat. No exact independent energy-yield or public model-and-BOM reliability result was located. Distributor certificate indexes were reviewed but not treated as evidence. Scope: Exact familyen.tongwei.cnkiwa.com
Walara G4PTindo Solar · AU priority 913Published3Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)tindosolar.com.au
- PID (IEC TS 62804)Published
- Independently tested / certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Salt mist (IEC 61701)Reviewed absence
- Exact source reviewed; qualifying disclosure not publishedtindosolar.com.au
- Ammonia resistance (IEC 62716)Published
- Not listedtindosolar.com.autindosolar.com.au
- Fire classification (IEC 61730)Published
- Certifiedtindosolar.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400tindosolar.com.au
- Negative loading (MQT16, Pa)Published
- 2400tindosolar.com.au
- Independent energy yieldPublished
- Not independently yield-testedtindosolar.com.au
- Verified reliabilityPublished
- Not independently testedtindosolar.com.autindosolar.com.au
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedtindosolar.com.autindosolar.com.au
- HailPublished
- 25 mm at 23 m/s. Scope: Exact Walara 440 G4Ptindosolar.com.au
- PIDPublished
- 1500 VDC for 96 h at 85 C and 85% RH. The sheet does not name the laboratory or certificate. Scope: Exact modeltindosolar.com.au
- Damp heat and thermal cyclingPublished
- Damp heat: 1000 h at 85 C and 85% RH. Thermal cycling: 200 cycles. These are baseline-duration results, not extended qualification. Scope: Exact modeltindosolar.com.au
- Fire classificationPublished
- Fire Class C. Scope: Exact modeltindosolar.com.au
- Mechanical loadPublished
- 5400 Pa front and 2400 Pa rear test load. Scope: Exact modeltindosolar.com.au
- Reviewed absenceReviewed absence
- No exact IEC 61701 salt result, IEC 62716 ammonia result, extended damp heat beyond 1000 h, EPD/product carbon declaration, independent current-model energy-yield result, or exact public enhanced-reliability report was located. DKA's Alice Springs array uses the older Karra 250, not G4P. Scope: Exact modeltindosolar.com.au
NGX-D3WINAICO · AU priority 1015Published3Reviewed absence0Not applicable1Open
- Hail resistancePublished
- Enhanced hail 35mm certifiedwinaico.comhagelregister.ch
- PID (IEC TS 62804)Published
- Claimed, no test citedwinaico.com.au
- Salt mist (IEC 61701)Published
- Severity 6winaico.com
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedwinaico.com
- Fire classification (IEC 61730)Published
- Certifiedwinaico.com.au
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 5400winaico.com.auwinaico.com
- Negative loading (MQT16, Pa)Published
- 2400winaico.com.auwinaico.com
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDPublished
- EPD verified, 400–650 kg CO₂/kWpwinaico.com
- HailPublished
- Accredited Swiss Hail Register classification HW3, recognition 33074, valid to 2029. An exact manufacturer hail report is also public. Scope: Exact WST-NGX-D3 familyhagelregister.chwinaico.com
- PIDPublished
- Exact datasheet claims PID resistance but publishes no test condition, result or certificate number. Scope: Exact WST-450NGX-D3winaico.com.au
- Salt mistPublished
- Exact-family IEC 61701 salt-mist certificate; manufacturer register identifies Severity 6. Scope: WST-NGX/NGXB-D3winaico.com
- AmmoniaPublished
- IEC 62716 certificate Z2 001256 0020 Rev01 covers WST-xxxNGX-D3, 445 W to 475 W. Scope: Exact wildcard includes scored modelwinaico.com
- Fire classificationPublished
- IEC 61730 fire Class C. Scope: Exact WST-450NGX-D3winaico.com.au
- Mechanical loadPublished
- For the manual's 2.0 mm glass and specified mounting configuration: design load 5400 Pa front and 2400 Pa rear; test load 8100 Pa front and 3600 Pa rear. The exact AU datasheet's general value is lower at 3600/1600 Pa design and 5400/2400 Pa test, so mounting and glass configuration must remain attached. Scope: WST-xxxNGX-D3, 400 W to 450 Wwinaico.comwinaico.com.au
- EPD/carbon footprintPublished
- Product EPD includes WST-xxxNGX-D3 and WST-xxxNGXB-D3. Scope: Exact familywinaico.com
- Reviewed absenceReviewed absence
- No exact PID certificate/numeric result, extended damp heat, independent energy-yield result, or exact public model-and-BOM reliability report was located. Scope: Exact familyhagelregister.chwinaico.comwinaico.com.auwinaico.comwinaico.comwinaico.comwinaico.com
Tiger Neo 48HL4M-DBJinko Solar · AU priority 1111Published4Reviewed absence0Not applicable1Open
- Hail resistancePublished
- IEC 61215 standard (25mm)jinkosolar.eu
- PID (IEC TS 62804)Published
- Independently tested / certifiedjinkosolar.eu
- Salt mist (IEC 61701)Published
- Certified (IEC 61701), severity not publishedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Ammonia resistance (IEC 62716)Published
- IEC 62716 certifiedcleanenergycouncil.org.aucleanenergycouncil.org.au
- Fire classification (IEC 61730)Published
- Certifiedjinkosolar.eu
- Damp heat extended (2000h)Open
- Not established
- Positive loading (MQT16, Pa)Published
- 6000jinkosolar.eu
- Negative loading (MQT16, Pa)Published
- 4000jinkosolar.eu
- Independent energy yieldReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Verified reliabilityReviewed absence
- Exact source reviewed; qualifying disclosure not publishedscorecard.pvel.comscorecard.pvel.com
- Carbon footprint / EPDReviewed absence
- Exact source reviewed; qualifying disclosure not publishedjinkosolar.eu
- HailPublished
- Baseline 25 mm hail statement. Scope: Exact 450 W to 475 W familyjinkosolar.eu
- PID, salt mist and ammoniaPublished
- Exact sheet lists IEC 62804, IEC 61701 and IEC 62716 and claims high salt-mist and ammonia resistance. No severity, certificate number or result is printed. Scope: Exact familyjinkosolar.eu
- Fire classificationPublished
- IEC fire Class C. Scope: Exact familyjinkosolar.eu
- Mechanical loadPublished
- 6000 Pa front and 4000 Pa rear maximum static test load. Scope: Exact familyjinkosolar.eu
- Reviewed absenceReviewed absence
- No exact enhanced hail result beyond the published baseline, extended damp heat, EPD/product carbon declaration, independent energy-yield result, or public exact-model reliability report was located. The broad Jinko EPD is not exact-series evidence. Scope: Exact familyjinkosolar.eu