Buying question
How much energy and power are usable, under what conditions, and what operating detail is withheld?
Evidence boundary
Published specifications are not independent field measurements. Where a source gives no test basis or duration, the record preserves that limitation.

Evidence by product

SigenStorSigenergy · AU priority 112Published5Reviewed absence0Not applicable2Open
Usable energy / DoD (%)Published
97sigenergy.comsigenergy.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
5.0sigenergy.comsigenergy.comcer.gov.aucer.gov.au
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedsigenergy.com
Thermal & fire mitigationPublished
Active thermal mgmt + fire suppression / cell isolationsigenergy.com
Cell provenance & traceabilityPublished
Supplier namedsigenergy.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedsigenergy.com
Modularity & scalabilityPublished
Fully modular / stackable expandablesigenergy.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsigenergy.comsigenergy.com
Warranty degradation guaranteePublished
Stepped guarantee: minimum capacity at midterm + end of termsigenergy.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablesigenergy.com
End-of-warranty retained capacity (%)Published
70sigenergy.com
exact_configurationPublished
One Sigen Battery 8 kWh module with 8.06 kWh total and 7.8 kWh usable is the audited battery reference.sigenergy.com
usable_energy_basisPublished
The exact BAT 8.0 datasheet publishes 7.8 kWh usable from 8.06 kWh total, approximately 97% usable energy.sigenergy.com
round_trip_efficiencyReviewed absence
The exact battery datasheet and AU/NZ warranty do not publish a comparable battery-system round-trip efficiency.sigenergy.comsigenergy.com
power_basisPublished
The exact BAT 8.0 datasheet publishes 6 kW peak charge and discharge for 10 seconds; realised AC output depends on the energy controller and stack.sigenergy.com
cell_balancingReviewed absence
Pack-level optimisers are disclosed, but active or passive cell-level balancing architecture is not established.sigenergy.com
source_accessOpen
The exact BAT 8.0 datasheet, AU/NZ warranty and current Australian primary URL returned HTTP 403 to an ordinary automated client on 2026-08-05; preserve or provide crawler handling without treating access denial as evidence withdrawal.sigenergy.comsigenergy.comsigenergy.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.sigenergy.com
Open the complete scorecard
Whispr 13.37PowerPlus Energy · AU priority 110Published3Reviewed absence0Not applicable4Open
Usable energy / DoD (%)Published
95powerplus-energy.com.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
7.0powerplus-energy.com.au
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedpowerplus-energy.com.aupowerplus-energy.com.au
Thermal & fire mitigationPublished
Passive thermal mgmtpowerplus-energy.com.aupowerplus-energy.com.au
Cell provenance & traceabilityPublished
Undisclosedpowerplus-energy.com.au
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldpowerplus-energy.com.au
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termpowerplus-energy.com.au
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablepowerplus-energy.com.au
End-of-warranty retained capacity (%)Published
70powerplus-energy.com.au
exact_configurationPublished
RX-7013Plus with 13.37 kWh storage and a 7 kW inverter is the audited reference.powerplus-energy.com.aupowerplus-energy.com.au
round_trip_efficiencyReviewed absence
No comparable exact battery or complete-system round-trip efficiency was established in the reviewed official source set.powerplus-energy.com.aupowerplus-energy.com.au
cycle_life_endpointReviewed absence
No exact cycle-life test to a stated retained-capacity endpoint was established.powerplus-energy.com.au
source_accessOpen
The exact Whispr specifications URL returned HTTP 404 on 2026-08-05; replace it with a current official document or preserve a verified copy before integrating new facts.powerplus-energy.com.aupowerplus-energy.com.au
standby_consumptionReviewed absence
No exact standby-consumption wattage was established.powerplus-energy.com.au
Open the complete scorecard
ESA G20GoodWe · AU priority 112Published2Reviewed absence0Not applicable5Open
Usable energy / DoD (%)Published
100goodwe.com.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
8.0goodwe.com.au
Operating temperature rangePublished
Standardgoodwe.com.au
Thermal & fire mitigationPublished
Passive thermal mgmtgoodwe.com.au
Cell provenance & traceabilityOpen
Not established
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldgoodwe.com.au
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termgoodwe.com.au
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablegoodwe.com.au
End-of-warranty retained capacity (%)Published
70goodwe.com.au
exact_configurationPublished
GW8K-EHA-G20 with GW8.3-BAT-D-G20 and 8.0 kWh usable is the audited configuration.goodwe.com.au
usable_energy_basisPublished
The exact datasheet publishes 8.32 kWh rated and 8.0 kWh usable at 100% depth of discharge, 0.2P and 25 C; actual available energy varies with rate, temperature, transport and storage.goodwe.com.au
round_trip_efficiencyReviewed absence
The exact datasheet publishes battery-to-AC and inverter efficiencies but no complete round-trip efficiency.goodwe.com.au
power_basisPublished
The exact battery table publishes 8 kW maximum input and output and 12 kW peak output for 10 seconds; power derates with temperature and state of charge.goodwe.com.au
thermal_fire_mitigationPublished
The exact June 2026 battery table publishes integrated aerosol fire extinguishing, model-dependent heating and natural-convection cooling.goodwe.com.au
cycle_life_endpointOpen
The exact table publishes at least 8,000 laboratory cycles but no retained-capacity endpoint; the claim must remain endpoint-unspecified.goodwe.com.au
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.goodwe.com.au
Open the complete scorecard
ALP LV E1Growatt · AU priority 111Published6Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
100au.growatt.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
5.0au.growatt.com
Operating temperature rangePublished
Standardau.growatt.com
Thermal & fire mitigationPublished
Passive thermal mgmtau.growatt.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.growatt.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.growatt.comau.growatt.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldau.growatt.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.growatt.comau.growatt.comau.growatt.com
Warranty degradation guaranteePublished
Stepped guarantee: minimum capacity at midterm + end of termau.growatt.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableau.growatt.com
End-of-warranty retained capacity (%)Published
60au.growatt.com
exact_configurationPublished
ALP 10.0L-E1 with two 5 kWh modules is the audited reference.au.growatt.com
usable_energy_basisPublished
The exact Australian datasheet publishes 10 kWh rated and usable at 100% depth of discharge.au.growatt.com
round_trip_efficiencyReviewed absence
The reviewed exact datasheet and warranty do not publish battery round-trip efficiency.au.growatt.comau.growatt.com
cycle_life_endpointReviewed absence
The reviewed exact datasheet and warranty do not publish a cycle-life result to a stated retained-capacity endpoint.au.growatt.comau.growatt.com
thermal_fire_mitigationPublished
The exact datasheet publishes natural cooling and does not publish active cooling or onboard fire suppression.au.growatt.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.au.growatt.com
Open the complete scorecard
IQ Battery 5P FlexPhaseEnphase · AU priority 17Published0Reviewed absence0Not applicable5Open
Usable energy / DoD (%)Published
100cer.gov.auenphase.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Open
Not established
Operating temperature rangePublished
Standardenphase.com
Thermal & fire mitigationPublished
Passive thermal mgmtenphase.com
Cell provenance & traceabilityOpen
Not established
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldenphase.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
Stepped guarantee: minimum capacity at midterm + end of termenphase.com
Warranty throughputPublished
>=5 MWh warranted per kWh usable (or >=5000-cycle equivalent)enphase.com
End-of-warranty retained capacity (%)Published
60enphase.com
Open the complete scorecard
Single Phase 5NeoVolt · AU priority 114Published1Reviewed absence0Not applicable3Open
Usable energy / DoD (%)Published
95neovoltess.com
Round-trip efficiency (%)Published
90neovoltess.com
Continuous power output (kW)Published
5.0neovoltess.com
Operating temperature rangePublished
Standardneovoltess.com
Thermal & fire mitigationPublished
Passive thermal mgmtneovoltess.com
Cell provenance & traceabilityPublished
Undisclosedneovoltess.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular / stackable expandableneovoltess.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termneovoltess.com
Warranty throughputPublished
Unlimited cycles for standard solar useneovoltess.com
End-of-warranty retained capacity (%)Published
70neovoltess.com
exact_configurationPublished
BW-INV-SPH5K with one BW-BAT-10.1P module is the audited configuration.neovoltess.com
usable_energy_basisPublished
The exact datasheet publishes 10.1 kWh nominal, 9.6 kWh usable and 95% depth of discharge.neovoltess.com
round_trip_efficiency_acPublished
The exact integrated-system datasheet publishes 90% maximum round-trip efficiency.neovoltess.com
power_basisPublished
The integrated system publishes 5 kW rated backup output, 10 kW surge backup power and transfer under 10 ms.neovoltess.com
cycle_life_endpointOpen
The exact datasheet publishes 8,000 cycles but no retained-capacity endpoint or cycle-test conditions; the current cycles-to-70% interpretation is unsupported.neovoltess.comneovoltess.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published; a 10 W battery discharge threshold is not standby consumption.neovoltess.com
Open the complete scorecard
APX S0 + MIN XH2Growatt · AU priority 19Published6Reviewed absence0Not applicable3Open
Usable energy / DoD (%)Published
100cleanenergycouncil.org.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
5.0cleanenergycouncil.org.auau.growatt.com
Operating temperature rangePublished
Standardau.growatt.com
Thermal & fire mitigationOpen
Not established
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.growatt.comau.growatt.comau.growatt.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldau.growatt.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.growatt.comau.growatt.com
Warranty degradation guaranteePublished
Stepped guarantee: minimum capacity at midterm + end of termau.growatt.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableau.growatt.com
End-of-warranty retained capacity (%)Published
50au.growatt.com
exact_configurationPublished
MIN 6000TL-XH2 with APX 10.0P-S0 AU and 10 kWh usable is the audited integrated reference.au.growatt.comau.growatt.com
usable_energy_basisPublished
The exact Australian configuration is listed at 10 kWh nominal and 10 kWh usable at 100% depth of discharge.au.growatt.comcleanenergycouncil.org.au
round_trip_efficiencyReviewed absence
No exact-system round-trip efficiency is published for MIN 6000TL-XH2 with APX 10.0P-S0 AU.au.growatt.comau.growatt.com
thermal_fire_mitigationReviewed absence
The reviewed exact datasheet and manual do not establish active thermal management or onboard fire suppression.au.growatt.comau.growatt.com
cell_balancingReviewed absence
No active or passive cell-level balancing architecture was disclosed.au.growatt.comau.growatt.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.au.growatt.comau.growatt.com
Open the complete scorecard
SBHSungrow · AU priority 210Published5Reviewed absence0Not applicable3Open
Usable energy / DoD (%)Published
100info-support.sungrowpower.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
10.56info-support.sungrowpower.com
Operating temperature rangePublished
Standardinfo-support.sungrowpower.comservice.sungrowpower.com.au
Thermal & fire mitigationPublished
Passive thermal mgmtinfo-support.sungrowpower.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedinfo-support.sungrowpower.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedsungrowpower.com
Modularity & scalabilityPublished
Fully modular / stackable expandableinfo-support.sungrowpower.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedinfo-support.sungrowpower.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termservice.sungrowpower.com.au
Warranty throughputPublished
Unlimited cycles for standard solar useservice.sungrowpower.com.au
End-of-warranty retained capacity (%)Published
70service.sungrowpower.com.au
product_identityOpen
The source record names SBH100-400 and stores one 5 kWh module as the scored reference, while the current official datasheet is SBH150-400.info-support.sungrowpower.comsungrowpower.com
minimum_configurationOpen
The current official SBH150-400 table begins at three 5 kWh modules and 15.0 kWh usable, extends to eight modules and 40.0 kWh, and does not list SBH100; the stored 5 kWh reference is not a complete current configuration.info-support.sungrowpower.com
usable_energy_basisPublished
The current SBH150-400 datasheet publishes usable energy at 100% depth of discharge, 25 C and 0.2C.info-support.sungrowpower.com
round_trip_efficiencyReviewed absence
No comparable battery round-trip efficiency is published in the current exact datasheet and warranty set.info-support.sungrowpower.comservice.sungrowpower.com.au
operating_deratingPublished
The current datasheet publishes charge from 0 C to 50 C, discharge from -20 C to 50 C, and power derating with temperature and state of charge.info-support.sungrowpower.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.info-support.sungrowpower.com
Open the complete scorecard
Battery-Box Premium LVSBYD · AU priority 213Published4Reviewed absence1Not applicable0Open
Usable energy / DoD (%)Published
100bydbatterybox.com
Round-trip efficiency (%)Published
95bydbatterybox.com
Continuous power output (kW)Published
10.0bydbatterybox.com
Operating temperature rangePublished
Standardbydbatterybox.com
Thermal & fire mitigationReviewed absence
Exact source reviewed; qualifying disclosure not publishedbydbatterybox.combydbatterybox.com
Cell provenance & traceabilityPublished
In-housebydbatterybox.combydglobal.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedbydbatterybox.combydbatterybox.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldbydbatterybox.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedbydbatterybox.combydbatterybox.combydbatterybox.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termbydbatterybox.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablebydbatterybox.com
End-of-warranty retained capacity (%)Published
60bydbatterybox.com
exact_configurationPublished
Battery-Box Premium LVS 12.0 with three 4 kWh modules is the audited reference.bydbatterybox.com
usable_energy_basisPublished
BYD publishes 12 kWh DC usable energy at 100% depth of discharge, 0.2C charge and discharge, and 25 C; system usable energy may vary with inverter brand.bydbatterybox.com
round_trip_efficiency_dcPublished
The exact Australian datasheet publishes at least 95% DC battery round-trip efficiency; this is not AC-to-battery-to-AC efficiency.bydbatterybox.com
operating_deratingPublished
The battery operates from -10 C to 50 C and charging derates between -10 C and 5 C.bydbatterybox.com
ac_backup_behaviourNot applicable
AC transfer and output are not battery-module properties for this DC battery and require a named inverter configuration.bydbatterybox.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.bydbatterybox.com
Open the complete scorecard
X1 Hybrid 3PHAnker SOLIX · AU priority 212Published4Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
100cleanenergycouncil.org.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
12salesforce-knowledge-download.s3.us-west-2.amazonaws.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Cell balancing architecturePublished
Pack-level only / not disclosedbeta.ankersolix.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldsalesforce-knowledge-download.s3.us-west-2.amazonaws.combeta.ankersolix.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termankersolix.com
Warranty throughputPublished
Throughput terms not publishedankersolix.comcleanenergycouncil.org.au
End-of-warranty retained capacity (%)Published
70ankersolix.com
exact_configurationPublished
X1-H12K-T with X1-B20-HC, comprising four X1-B5-H modules, is the audited 20 kWh configuration.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
power_basisPublished
The system publishes 12 kW continuous three-phase AC output and a typical under-10 ms switch time; these are integrated power-module facts.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
round_trip_efficiencyReviewed absence
No comparable complete-system round-trip efficiency is published; inverter efficiency is not substituted.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
operating_deratingPublished
Each 5 kWh battery module operates from -20 C to 55 C; the integrated power module derates above 45 C.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
Open the complete scorecard
ReservaFronius · AU priority 212Published1Reviewed absence0Not applicable4Open
Usable energy / DoD (%)Published
100fronius.com
Round-trip efficiency (%)Published
95fronius.com
Continuous power output (kW)Published
6.55fronius.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedfronius.com
Thermal & fire mitigationOpen
Not established
Cell provenance & traceabilityOpen
Not established
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldfronius.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termfronius.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablefronius.com
End-of-warranty retained capacity (%)Published
70fronius.com
exact_configurationPublished
Reserva 6.3 with two modules and 6.31 kWh usable is the audited reference.fronius.com
round_trip_efficiency_dcPublished
Fronius publishes 95% DC battery efficiency at 0.2C and 25 C; this is not AC-to-battery-to-AC RTE.fronius.com
power_basisPublished
The reference publishes 6.55 kW maximum battery-side charge and discharge power, which may vary with temperature, state of charge and connected inverter.fronius.com
cycle_life_basisPublished
The exact datasheet publishes 6,000 cycles to 60% state of health; it must not populate a field specifically labelled cycles to 70%.fronius.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.fronius.com
Open the complete scorecard
Three Phase 10NeoVolt · AU priority 214Published1Reviewed absence0Not applicable3Open
Usable energy / DoD (%)Published
96neovoltess.com
Round-trip efficiency (%)Published
96neovoltess.com
Continuous power output (kW)Published
10.0neovoltess.com
Operating temperature rangePublished
Standardneovoltess.com
Thermal & fire mitigationPublished
Passive thermal mgmtneovoltess.com
Cell provenance & traceabilityPublished
Undisclosedneovoltess.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldneovoltess.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termneovoltess.com
Warranty throughputPublished
Unlimited cycles for standard solar useneovoltess.com
End-of-warranty retained capacity (%)Published
70neovoltess.com
exact_configurationPublished
BW-INV-TPH10K with two BW-BAT-4.8S modules is the audited configuration.neovoltess.com
usable_energy_basisPublished
The exact datasheet publishes 9.6 kWh nominal, 9.2 kWh usable and 96% depth of discharge.neovoltess.com
round_trip_efficiency_acPublished
The exact integrated-system datasheet publishes 96% maximum round-trip efficiency.neovoltess.com
power_basisPublished
The integrated system publishes 10 kW rated backup output, 20 kW surge backup power and transfer under 10 ms.neovoltess.com
cycle_life_endpointOpen
The exact datasheet publishes 8,000 cycles but no retained-capacity endpoint or cycle-test conditions; the current cycles-to-70% interpretation is unsupported.neovoltess.comneovoltess.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published; a 10 W battery discharge threshold is not standby consumption.neovoltess.com
Open the complete scorecard
X1 Hybrid 1PHAnker SOLIX · AU priority 212Published4Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
100cleanenergycouncil.org.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
6salesforce-knowledge-download.s3.us-west-2.amazonaws.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Cell balancing architecturePublished
Pack-level only / not disclosedbeta.ankersolix.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldsalesforce-knowledge-download.s3.us-west-2.amazonaws.combeta.ankersolix.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termankersolix.com
Warranty throughputPublished
Throughput terms not publishedankersolix.comcleanenergycouncil.org.au
End-of-warranty retained capacity (%)Published
70ankersolix.com
exact_configurationPublished
X1-H6K-S with X1-B10-HC, comprising two X1-B5-H modules, is the audited 10 kWh configuration.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
power_basisPublished
The system publishes 6 kW continuous AC output and an under-10 ms switch time; these are integrated power-module facts, not standalone battery-module output.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
round_trip_efficiencyReviewed absence
No comparable complete-system round-trip efficiency is published; inverter efficiency is not substituted.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
operating_deratingPublished
Each 5 kWh battery module operates from -20 C to 55 C; the integrated power module derates above 45 C.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
Open the complete scorecard
X1 AC-coupledAnker SOLIX · AU priority 212Published4Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
100cleanenergycouncil.org.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
6salesforce-knowledge-download.s3.us-west-2.amazonaws.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Cell balancing architecturePublished
Pack-level only / not disclosedbeta.ankersolix.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldsalesforce-knowledge-download.s3.us-west-2.amazonaws.combeta.ankersolix.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsalesforce-knowledge-download.s3.us-west-2.amazonaws.comankersolix.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termankersolix.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableankersolix.comcleanenergycouncil.org.au
End-of-warranty retained capacity (%)Published
70ankersolix.com
exact_configurationPublished
X1-P6K-B10-S is the audited fixed 10 kWh AC-coupled configuration.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
usable_energy_basisPublished
The exact Australian configuration is listed at 10 kWh nominal and 10 kWh usable.salesforce-knowledge-download.s3.us-west-2.amazonaws.comcleanenergycouncil.org.au
round_trip_efficiencyReviewed absence
The exact datasheet publishes inverter maximum efficiency but no AC-to-battery-to-AC round-trip efficiency for the fixed configuration.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
operating_deratingPublished
The battery module operates from -20 C to 55 C and the power module derates above 45 C.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.salesforce-knowledge-download.s3.us-west-2.amazonaws.com
Open the complete scorecard
Hybrid Battery Max BE21HVRedback Technologies · AU priority 29Published2Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
95digital.redbacktech.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
9.99digital.redbacktech.comdigital.redbacktech.com
Operating temperature rangePublished
Standarddigital.redbacktech.com
Thermal & fire mitigationPublished
Passive thermal mgmtdigital.redbacktech.com
Cell provenance & traceabilityPublished
Undiscloseddigital.redbacktech.comdigital.redbacktech.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publisheddigital.redbacktech.com
Modularity & scalabilityPublished
Fully modular / stackable expandabledigital.redbacktech.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publisheddigital.redbacktech.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termdigital.redbacktech.comdigital.redbacktech.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usabledigital.redbacktech.comdigital.redbacktech.com
End-of-warranty retained capacity (%)Published
70digital.redbacktech.comdigital.redbacktech.com
Open the complete scorecard
Smile M5AlphaESS · AU priority 211Published3Reviewed absence0Not applicable3Open
Usable energy / DoD (%)Published
100alphaess.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
5.0alphaess.au
Operating temperature rangePublished
Standardalphaess.au
Thermal & fire mitigationPublished
Basicalphaess.au
Cell provenance & traceabilityPublished
Undisclosedalphaess.au
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldalphaess.au
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termcdn.shopify.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablecdn.shopify.com
End-of-warranty retained capacity (%)Published
70cdn.shopify.com
exact_configurationPublished
SMILE-M5-S-INV with one SMILE-M-BAT-13.9P module is the audited 5 kW single-phase reference.alphaess.aucdn.shopify.com
usable_energy_basisPublished
The reference publishes 13.99 kWh at 100% depth of discharge and supports one or two matching battery modules.alphaess.aucdn.shopify.com
round_trip_efficiencyReviewed absence
The reviewed exact source set does not establish a comparable battery or system round-trip efficiency; product-level maximum efficiency is not substituted.cdn.shopify.comcdn.shopify.com
cell_balancingReviewed absence
No active or passive cell-level balancing architecture was located in the reviewed exact material.alphaess.aucdn.shopify.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was located.cdn.shopify.com
Open the complete scorecard
B2 HV + H2SAJ · AU priority 27Published4Reviewed absence0Not applicable7Open
Usable energy / DoD (%)Published
96saj-electric.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
6.0cleanenergycouncil.org.ausaj-electric.com
Operating temperature rangeOpen
Not established
Thermal & fire mitigationOpen
Not established
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsaj-electric.comsaj-electric.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldsaj-electric.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsaj-electric.comsaj-electric.com
Warranty degradation guaranteeOpen
Not established
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablesaj-electric.com
End-of-warranty retained capacity (%)Open
Not established
exact_configurationPublished
H2-6K-S2 with B2-10.0-HV5 is the audited configuration.saj-electric.com
usable_energy_correctionOpen
The exact B2-10.0-HV5 table publishes 10.0 kWh rated, 9.0 kWh usable and 90% depth of discharge; the current 9.6 kWh and 96% record values conflict with the exact datasheet and must be held for correction unless superseded by newer exact Australian evidence.saj-electric.com
power_basisPublished
The exact battery table publishes 6.144 kW rated DC battery power for B2-10.0-HV5; the 6 kW H2 value is integrated AC inverter output.saj-electric.com
round_trip_efficiencyReviewed absence
No comparable battery or complete-system round-trip efficiency was published in the reviewed exact source set.saj-electric.com
thermal_managementPublished
The exact battery datasheet publishes natural-convection cooling, charge from 0 C to 50 C and discharge from -10 C to 50 C; no onboard suppression is disclosed.saj-electric.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.saj-electric.com
Open the complete scorecard
Powerwall 3Tesla · AU priority 314Published5Reviewed absence0Not applicable0Open
Usable energy / DoD (%)Published
100energylibrary.tesla.com
Round-trip efficiency (%)Published
89energylibrary.tesla.com
Continuous power output (kW)Published
11.04energylibrary.tesla.comcer.gov.au
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedenergylibrary.tesla.com
Thermal & fire mitigationPublished
Basicenergylibrary.tesla.comenergylibrary.tesla.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedenergylibrary.tesla.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedenergylibrary.tesla.comenergylibrary.tesla.com
Modularity & scalabilityPublished
Fully modular / stackable expandableenergylibrary.tesla.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedenergylibrary.tesla.comenergylibrary.tesla.comsolar.htw-berlin.de
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termenergylibrary.tesla.com
Warranty throughputPublished
Unlimited cycles for standard solar useenergylibrary.tesla.com
End-of-warranty retained capacity (%)Published
70energylibrary.tesla.com
exact_configurationPublished
Australian Powerwall 3 is the audited integrated configuration.energylibrary.tesla.com
usable_energy_basisPublished
The exact Australian datasheet publishes 13.5 kWh usable battery energy on an AC basis.energylibrary.tesla.com
round_trip_efficiency_pathPublished
Tesla publishes 89% solar-to-battery-to-home/grid efficiency; this path is not generic AC-to-battery-to-AC or DC battery round-trip efficiency.energylibrary.tesla.com
power_basisPublished
The current Australian datasheet publishes 11.04 kW continuous AC output; exact backup documentation publishes 185 locked-rotor amps for one second.energylibrary.tesla.comenergylibrary.tesla.com
operating_deratingPublished
Powerwall 3 operates from -20 C to 50 C and may derate above 40 C.energylibrary.tesla.com
cycle_life_endpointReviewed absence
The reviewed exact datasheet and Australian warranty do not publish a cycle-life test to a stated retained-capacity endpoint; the 70% figure is a warranty condition.energylibrary.tesla.comenergylibrary.tesla.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.energylibrary.tesla.com
Open the complete scorecard
CQ7FoxESS · AU priority 39Published3Reviewed absence0Not applicable0Open
Usable energy / DoD (%)Published
100au.fox-ess.com
Round-trip efficiency (%)Published
95au.fox-ess.com
Continuous power output (kW)Published
5.76au.fox-ess.comau.fox-ess.com
Operating temperature rangePublished
Standardau.fox-ess.com
Thermal & fire mitigationPublished
Passive thermal mgmtau.fox-ess.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.fox-ess.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.fox-ess.com
Modularity & scalabilityPublished
Fully modular / stackable expandableau.fox-ess.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.fox-ess.comsolar.htw-berlin.de
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termau.fox-ess.com
Warranty throughputPublished
>=5 MWh warranted per kWh usable (or >=5000-cycle equivalent)au.fox-ess.com
End-of-warranty retained capacity (%)Published
70au.fox-ess.com
Open the complete scorecard
RESU PrimeLG Energy Solution · AU priority 315Published3Reviewed absence0Not applicable0Open
Usable energy / DoD (%)Published
100lgessbattery.com
Round-trip efficiency (%)Published
90.3lgessbattery.com
Continuous power output (kW)Published
7.0lgessbattery.com
Operating temperature rangePublished
Standardlgessbattery.com
Thermal & fire mitigationPublished
Passive thermal mgmtlgessbattery.com
Cell provenance & traceabilityPublished
In-houselgessbattery.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedlgessbattery.comlgessbattery.com
Modularity & scalabilityPublished
Partially expandablelgessbattery.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedlgessbattery.comlgessbattery.comlgessbattery.comlgessbattery.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termlgessbattery.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablelgessbattery.com
End-of-warranty retained capacity (%)Published
70lgessbattery.com
exact_configurationPublished
RESU 16H Prime is the audited reference.lgessbattery.com
usable_energy_basisPublished
The exact datasheet publishes 16.45 kWh nominal and 16.0 kWh usable at 100% depth of discharge, 25 C and the stated 0.3C conditions.lgessbattery.com
round_trip_efficiencyPublished
The exact Australian warranty schedule publishes greater than 90.3% round-trip efficiency under its stated test condition; the measurement boundary must remain attached.lgessbattery.com
power_basisPublished
The exact 16H Prime datasheet publishes 7 kW maximum charge and discharge and 11 kW peak discharge for 10 seconds.lgessbattery.com
operating_deratingPublished
Charge is -10 C to 50 C and discharge is -20 C to 50 C, while the recommended operating range is 15 C to 30 C.lgessbattery.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.lgessbattery.com
Open the complete scorecard
Smile M10AlphaESS · AU priority 311Published3Reviewed absence0Not applicable3Open
Usable energy / DoD (%)Published
100cdn.shopify.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
10.0cdn.shopify.com
Operating temperature rangePublished
Standardcdn.shopify.com
Thermal & fire mitigationPublished
Basiccdn.shopify.com
Cell provenance & traceabilityPublished
Undisclosedcdn.shopify.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular / stackable expandablecdn.shopify.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termcdn.shopify.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablecdn.shopify.com
End-of-warranty retained capacity (%)Published
70cdn.shopify.com
exact_configurationPublished
SMILE-M10-S-INV with one SMILE-M-BAT-13.9P module is the audited 10 kW single-phase reference.cdn.shopify.com
usable_energy_basisPublished
The reference publishes 13.99 kWh at 100% depth of discharge and supports one or two matching battery modules.cdn.shopify.com
round_trip_efficiencyReviewed absence
The reviewed exact datasheet and warranty do not establish a comparable battery or system round-trip efficiency; inverter maximum efficiency is not substituted.cdn.shopify.comcdn.shopify.com
cycle_life_endpointReviewed absence
No exact cycle-life test to a stated retained-capacity endpoint was located; warranty throughput and 70% retention remain contractual conditions, not a cycle test.cdn.shopify.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was located.cdn.shopify.com
Open the complete scorecard
EP760 + B500BLUETTI · AU priority 312Published3Reviewed absence0Not applicable2Open
Usable energy / DoD (%)Published
89.9cleanenergycouncil.org.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
7.6cdn.shopify.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedcdn.shopify.comcdn.shopify.com
Thermal & fire mitigationPublished
Basiccdn.shopify.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedcdn.shopify.comcdn.shopify.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldcdn.shopify.comcdn.shopify.comcdn.shopify.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedcdn.shopify.comcdn.shopify.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termcdn.shopify.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablecdn.shopify.com
End-of-warranty retained capacity (%)Published
70cdn.shopify.com
exact_configurationPublished
EP760 with two B500 modules, 9.92 kWh nominal and 8.92 kWh usable, is the audited configuration.cdn.shopify.comcdn.shopify.com
power_basisPublished
The integrated EP760 publishes 7.6 kW continuous AC output, 100% to 110% overload for 10 minutes, 110% to 150% for 10 seconds, and under-10 ms transfer.cdn.shopify.com
round_trip_efficiencyReviewed absence
The exact system specification publishes 94.5% peak inversion efficiency but no comparable battery or complete-system round-trip efficiency.cdn.shopify.com
standby_consumptionPublished
The exact EP760 specification publishes 75 W standby power for the integrated system; this is not standalone B500 battery-module parasitic draw.cdn.shopify.com
thermal_managementPublished
The integrated EP760 uses forced-air cooling and publishes an operating range of -20 C to 50 C.cdn.shopify.com
Open the complete scorecard
APX HV S2Growatt · AU priority 39Published4Reviewed absence0Not applicable5Open
Usable energy / DoD (%)Published
100au.growatt.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
5.0au.growatt.com
Operating temperature rangePublished
Standardau.growatt.com
Thermal & fire mitigationOpen
Not established
Cell provenance & traceabilityOpen
Not established
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldau.growatt.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
Stepped guarantee: minimum capacity at midterm + end of termau.growatt.com
Warranty throughputPublished
Throughput terms not publishedau.growatt.com
End-of-warranty retained capacity (%)Published
50au.growatt.com
exact_configurationPublished
APX 10.0P-S2 AU with 10 kWh usable is the audited reference.au.growatt.com
usable_energy_basisPublished
The exact Australian datasheet publishes 10 kWh nominal and usable at 100% depth of discharge.au.growatt.com
round_trip_efficiencyReviewed absence
The reviewed exact datasheet and warranty do not publish a comparable round-trip efficiency.au.growatt.comau.growatt.com
warranty_throughputReviewed absence
The governing APX warranty publishes time and retained-capacity conditions but no energy-throughput allowance.au.growatt.com
cycle_life_endpointReviewed absence
No exact cycle-life result to a stated retained-capacity endpoint was published.au.growatt.comau.growatt.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.au.growatt.com
Open the complete scorecard
Battery-Box Premium HVSBYD · AU priority 414Published2Reviewed absence1Not applicable1Open
Usable energy / DoD (%)Published
100bydbatterybox.com
Round-trip efficiency (%)Published
96.9solar.htw-berlin.desolar.htw-berlin.de
Continuous power output (kW)Published
10.2bydbatterybox.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedbydbatterybox.com
Thermal & fire mitigationOpen
Not established
Cell provenance & traceabilityPublished
In-housebydbatterybox.comess-news.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedbydbatterybox.combydbatterybox.com
Modularity & scalabilityPublished
Fully modular / stackable expandablebydbatterybox.com
Verified reliabilityPublished
Independently testedsolar.htw-berlin.desolar.htw-berlin.de
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termbydbatterybox.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablebydbatterybox.com
End-of-warranty retained capacity (%)Published
70bydbatterybox.com
exact_configurationPublished
Battery-Box Premium HVS 10.2 with four HVS modules is the audited configuration.bydbatterybox.com
usable_energy_basisPublished
BYD publishes 10.24 kWh DC usable energy at 100% depth of discharge, 0.2C charge and discharge, and 25 C; system usable energy may vary with inverter brand.bydbatterybox.com
round_trip_efficiency_dcPublished
The exact Australian datasheet publishes at least 96% DC battery round-trip efficiency; this is not AC-to-battery-to-AC efficiency.bydbatterybox.com
operating_deratingPublished
The battery operates from -10 C to 50 C and charging derates between -10 C and 5 C.bydbatterybox.com
ac_backup_behaviourNot applicable
AC output, transfer time and motor-start capability are not battery-module properties for this DC-coupled battery and require a named inverter configuration.bydbatterybox.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.bydbatterybox.com
Open the complete scorecard
CygniDyness · AU priority 412Published4Reviewed absence0Not applicable2Open
Usable energy / DoD (%)Published
95au.dyness.comcleanenergycouncil.org.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
9.999au.dyness.comcleanenergycouncil.org.au
Operating temperature rangePublished
Standardau.dyness.com
Thermal & fire mitigationPublished
Passive thermal mgmtau.dyness.comau.dyness.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.dyness.comau.dyness.comau.dyness.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldau.dyness.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.dyness.comau.dyness.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termau.dyness.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableau.dyness.com
End-of-warranty retained capacity (%)Published
70au.dyness.com
exact_configurationPublished
Cygni 10.0HS-M4 with 15.36 kWh nominal and 14.59 kWh usable is the audited configuration.au.dyness.com
usable_energy_basisPublished
The exact configuration publishes 14.59 kWh usable from 15.36 kWh nominal, equal to 95% depth of discharge after rounding.au.dyness.com
round_trip_efficiencyReviewed absence
The reviewed exact datasheet and manual publish inverter efficiency but no comparable complete-system round-trip efficiency.au.dyness.comau.dyness.com
cycle_life_basisPublished
The exact datasheet publishes at least 8,000 cycles to 70% state of health.au.dyness.com
thermal_fire_mitigationPublished
The exact integrated system publishes natural-convection cooling and a built-in aerosol fire extinguisher; suppression does not establish active cooling.au.dyness.comau.dyness.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.au.dyness.comau.dyness.com
Open the complete scorecard
Smile G3 S5 BAT-9.3SAlphaESS · AU priority 412Published2Reviewed absence0Not applicable3Open
Usable energy / DoD (%)Published
100alphaesspartner.blob.core.windows.net
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
5alphaesspartner.blob.core.windows.net
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedalphaesspartner.blob.core.windows.net
Thermal & fire mitigationPublished
Basicalphaesspartner.blob.core.windows.net
Cell provenance & traceabilityPublished
Undisclosedalphaesspartner.blob.core.windows.net
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular / stackable expandablealphaesspartner.blob.core.windows.net
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termalphaesspartner.blob.core.windows.net
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablealphaesspartner.blob.core.windows.net
End-of-warranty retained capacity (%)Published
70alphaesspartner.blob.core.windows.net
exact_configurationPublished
SMILE-G3-S5-INV with one SMILE-G3-BAT-9.3S module is the audited configuration.alphaesspartner.blob.core.windows.net
usable_energy_basisPublished
The exact Australian datasheet publishes 9.3 kWh usable at 100% depth of discharge; one to four modules are connected in series.alphaesspartner.blob.core.windows.net
round_trip_efficiencyReviewed absence
The reviewed exact datasheet and warranty do not publish a comparable battery or complete-system round-trip efficiency.alphaesspartner.blob.core.windows.netalphaesspartner.blob.core.windows.net
thermal_fire_mitigationPublished
The exact datasheet publishes fast-suppression aerosol fire defence and a -20 C to 50 C module operating range, with performance dependent on state of charge and temperature.alphaesspartner.blob.core.windows.net
standby_consumptionReviewed absence
No exact standby or parasitic-consumption wattage was located in the reviewed exact source set.alphaesspartner.blob.core.windows.netalphaesspartner.blob.core.windows.net
Open the complete scorecard
H10S 17.8Hinen · AU priority 49Published4Reviewed absence0Not applicable5Open
Usable energy / DoD (%)Open
Not established
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
10.0au.hinen.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedau.hinen.com
Thermal & fire mitigationPublished
Basicau.hinen.com
Cell provenance & traceabilityPublished
Undisclosedau.hinen.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular / stackable expandableau.hinen.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termau.hinen.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableau.hinen.com
End-of-warranty retained capacity (%)Published
80au.hinen.com
exact_configurationPublished
A10000S with two B8900M-HA modules and 17.8 kWh nominal storage is the audited configuration.au.hinen.comau.hinen.com
usable_energy_basisOpen
The reviewed public exact product and service documents do not establish usable energy or depth of discharge for the 17.8 kWh nominal configuration.au.hinen.comau.hinen.comcdn.shopify.com
round_trip_efficiencyReviewed absence
The 98% headline is inverter maximum efficiency; no comparable battery or complete-system round-trip efficiency is published.au.hinen.com
cycle_life_endpointReviewed absence
No exact cycle-life result to a stated retained-capacity endpoint was located.au.hinen.comcdn.shopify.com
cell_balancingReviewed absence
No active or passive cell-level balancing architecture was disclosed.au.hinen.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.au.hinen.com
Open the complete scorecard
Force H3XPylontech · AU priority 49Published3Reviewed absence0Not applicable6Open
Usable energy / DoD (%)Published
95cer.gov.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
6.0pylonwebs3.s3.amazonaws.com
Operating temperature rangePublished
Standardpylonwebs3.s3.amazonaws.com
Thermal & fire mitigationPublished
Basicpylonwebs3.s3.amazonaws.com
Cell provenance & traceabilityOpen
Not established
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular / stackable expandablepylonwebs3.s3.amazonaws.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termpylonwebs3.s3.amazonaws.com
Warranty throughputReviewed absence
Exact source reviewed; qualifying disclosure not publishedpylonwebs3.s3.amazonaws.com
End-of-warranty retained capacity (%)Published
60pylonwebs3.s3.amazonaws.com
exact_configurationPublished
Force H3X HY-1P 6 kW with two FH10050 modules and 10.24 kWh nominal is the audited reference.pylonwebs3.s3.amazonaws.com
usable_energy_basisOpen
The reviewed exact manual and warranty do not establish usable energy or depth of discharge for the 10.24 kWh nominal reference.pylonwebs3.s3.amazonaws.compylonwebs3.s3.amazonaws.com
round_trip_efficiencyReviewed absence
No comparable battery or complete-system round-trip efficiency was published.pylonwebs3.s3.amazonaws.com
thermal_fire_mitigationPublished
The manual requires an external fire-extinguisher system and states that Force H3X is not equipped with a fire alarm; this is not onboard suppression.pylonwebs3.s3.amazonaws.com
warranty_performanceOpen
Exact warranty throughput and retained-capacity endpoint were not established in the reviewed exact-family terms.pylonwebs3.s3.amazonaws.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.pylonwebs3.s3.amazonaws.com
Open the complete scorecard
sonnenBatterie Evosonnen · AU priority 46Published0Reviewed absence0Not applicable6Open
Usable energy / DoD (%)Published
90.9media.sonnengroup.comcer.gov.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Open
Not established
Operating temperature rangeOpen
Not established
Thermal & fire mitigationPublished
Basicmedia.sonnengroup.com
Cell provenance & traceabilityOpen
Not established
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fixed single unitmedia.sonnengroup.commedia.sonnengroup.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termmedia.sonnengroup.com
Warranty throughputPublished
>=5 MWh warranted per kWh usable (or >=5000-cycle equivalent)media.sonnengroup.com
End-of-warranty retained capacity (%)Published
80media.sonnengroup.com
Open the complete scorecard
Home BatterySolarEdge · AU priority 515Published3Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
97.0knowledge-center.solaredge.com
Round-trip efficiency (%)Published
94.5knowledge-center.solaredge.com
Continuous power output (kW)Published
5knowledge-center.solaredge.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedknowledge-center.solaredge.com
Thermal & fire mitigationPublished
Passive thermal mgmtnatec.comsolarquotes.com.au
Cell provenance & traceabilityPublished
In-houseenergystorage.solaredge.cominvestors.solaredge.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedsolaredge.com
Modularity & scalabilityPublished
Fully modular / stackable expandableknowledge-center.solaredge.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedknowledge-center.solaredge.comknowledge-center.solaredge.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termknowledge-center.solaredge.com
Warranty throughputPublished
Unlimited cycles for standard solar useknowledge-center.solaredge.com
End-of-warranty retained capacity (%)Published
70knowledge-center.solaredge.com
exact_configurationPublished
SolarEdge Home Battery 400V BAT-10K1PS0B-x2 with 9.7 kWh usable is the audited product.knowledge-center.solaredge.com
usable_energy_basisPublished
The current exact Australian datasheet publishes 9.7 kWh usable at 100% depth of discharge.knowledge-center.solaredge.com
round_trip_efficiency_dcPublished
The exact Australian datasheet publishes 94.5% peak round-trip efficiency for the DC-coupled battery path; this is not AC-to-battery-to-AC RTE.knowledge-center.solaredge.com
power_basisPublished
The exact Australian datasheet publishes 5 kW continuous DC battery output and 7.5 kW peak for 10 seconds; AC backup output remains inverter-dependent.knowledge-center.solaredge.com
thermal_fire_mitigationPublished
The exact safety sheet describes an optional fire extinguisher; this does not prove every shipped unit includes one.knowledge-center.solaredge.com
source_accessOpen
The current Australian product page, exact datasheet, warranty and safety sheet returned HTTP 403 to an ordinary automated client on 2026-08-05; use the exact document pointer with preservation or crawler handling.solaredge.comknowledge-center.solaredge.comknowledge-center.solaredge.comknowledge-center.solaredge.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.knowledge-center.solaredge.com
Open the complete scorecard
vBox 14VoltX · AU priority 513Published2Reviewed absence0Not applicable3Open
Usable energy / DoD (%)Published
90voltxcommercial.com.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
5.4voltxcommercial.com.au
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedvoltxcommercial.com.au
Thermal & fire mitigationPublished
Passive thermal mgmtvoltxcommercial.com.au
Cell provenance & traceabilityPublished
Undisclosedvoltxcommercial.com.au
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldvoltxcommercial.com.au
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termvoltxcommercial.com.au
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablevoltxcommercial.com.au
End-of-warranty retained capacity (%)Published
70voltxcommercial.com.au
exact_configurationPublished
vBox-14 with four vBox-3.5-M modules is the audited reference.voltxcommercial.com.au
usable_energy_basisPublished
The exact Australian datasheet publishes 13.8 kWh total and 12.4 kWh usable at 90% depth of discharge, 25 C and 0.2C.voltxcommercial.com.au
round_trip_efficiencyReviewed absence
No comparable exact battery round-trip efficiency was published.voltxcommercial.com.au
power_basisPublished
The reference publishes 5.4 kW continuous battery output and 6.4 kW maximum output without a duration; the maximum is not a duration-bound motor-start rating.voltxcommercial.com.au
operating_deratingPublished
The exact datasheet publishes -20 C to 55 C operation with power derating above 45 C and natural-convection cooling.voltxcommercial.com.au
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.voltxcommercial.com.au
Open the complete scorecard
All-in-One AC-CoupledGivEnergy · AU priority 57Published0Reviewed absence0Not applicable5Open
Usable energy / DoD (%)Published
100givenergy.comcer.gov.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Open
Not established
Operating temperature rangePublished
Standardgivenergy.comgivenergy.com
Thermal & fire mitigationPublished
Passive thermal mgmtgivenergy.com
Cell provenance & traceabilityOpen
Not established
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular / stackable expandablegivenergy.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termgivenergy.com
Warranty throughputPublished
Unlimited cycles for standard solar usegivenergy.com
End-of-warranty retained capacity (%)Published
70givenergy.com
Open the complete scorecard
HM6ESY SUNHOME · AU priority 510Published2Reviewed absence0Not applicable6Open
Usable energy / DoD (%)Open
Not established
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
6.0esysunhome.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedesysunhome.com
Thermal & fire mitigationPublished
Passive thermal mgmtesysunhome.com
Cell provenance & traceabilityOpen
Not established
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular / stackable expandableesysunhome.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termesysunhome.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableesysunhome.com
End-of-warranty retained capacity (%)Published
70esysunhome.com
exact_configurationPublished
HM6 with two 5.12 kWh modules, 10.24 kWh nominal and a 6 kW integrated power stage, is the audited reference.esysunhome.com
usable_energy_basisOpen
The reviewed exact source set does not publish usable energy or a depth-of-discharge basis for the 10.24 kWh nominal reference.esysunhome.comesysunhome.com
round_trip_efficiencyReviewed absence
The datasheet publishes inverter maximum efficiency but no comparable battery or complete-system round-trip efficiency.esysunhome.com
power_basisPublished
The integrated system publishes 105% output for 60 seconds, 120% for 30 seconds and switch time no more than 20 ms.esysunhome.com
operating_deratingPublished
The integrated system operates from -25 C to 60 C and derates above 45 C.esysunhome.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.esysunhome.com
Open the complete scorecard
Hybrid Battery System G3Redback Technologies · AU priority 69Published2Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
95digital.redbacktech.comdigital.redbacktech.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
6.0digital.redbacktech.com
Operating temperature rangePublished
Standarddigital.redbacktech.com
Thermal & fire mitigationPublished
Passive thermal mgmtdigital.redbacktech.comdigital.redbacktech.com
Cell provenance & traceabilityPublished
Supplier nameddigital.redbacktech.comdigital.redbacktech.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publisheddigital.redbacktech.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fielddigital.redbacktech.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publisheddigital.redbacktech.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termstatic.redbacktech.comdigital.redbacktech.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablestatic.redbacktech.comdigital.redbacktech.com
End-of-warranty retained capacity (%)Published
70static.redbacktech.comdigital.redbacktech.com
Open the complete scorecard
EQ4800FoxESS · AU priority 715Published3Reviewed absence0Not applicable0Open
Usable energy / DoD (%)Published
100au.fox-ess.com
Round-trip efficiency (%)Published
95au.fox-ess.com
Continuous power output (kW)Published
4.48au.fox-ess.com
Operating temperature rangePublished
Standardau.fox-ess.com
Thermal & fire mitigationPublished
Passive thermal mgmtau.fox-ess.com
Cell provenance & traceabilityPublished
Undisclosedau.fox-ess.comau.fox-ess.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.fox-ess.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldau.fox-ess.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.fox-ess.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termau.fox-ess.comau.fox-ess.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableau.fox-ess.com
End-of-warranty retained capacity (%)Published
70au.fox-ess.comau.fox-ess.com
exact_configurationPublished
EQ4800-L2 with two modules and 9.32 kWh usable is the audited reference.au.fox-ess.com
usable_energy_basisPublished
The exact datasheet publishes 9.32 kWh nominal and usable at 100% depth of discharge.au.fox-ess.com
round_trip_efficiency_dcPublished
The exact datasheet publishes greater than 95% battery-pack round-trip efficiency; this is a DC battery-pack figure, not AC system RTE.au.fox-ess.com
power_basisPublished
The reference publishes 4.48 kW nominal battery power and a peak discharge current with a 60-second duration; AC motor-start capability is not established.au.fox-ess.com
operating_deratingPublished
Charge is published from 0 C to 55 C and discharge from -10 C to 55 C; current varies with temperature, cell voltage and state of charge.au.fox-ess.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.au.fox-ess.com
Open the complete scorecard
SBRSungrow · AU priority 812Published4Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
100aus.sungrowpower.comsungrowpower.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
5.76aus.sungrowpower.comsungrowpower.com
Operating temperature rangePublished
Standardaus.sungrowpower.comsungrowpower.com
Thermal & fire mitigationPublished
Passive thermal mgmtaus.sungrowpower.comsungrowpower.com
Cell provenance & traceabilityPublished
Undisclosedinfo-support.sungrowpower.comsungrowpower.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedinfo-support.sungrowpower.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldsungrowpower.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsungrowpower.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termservice.sungrowpower.com.ausungrowpower.com
Warranty throughputPublished
Unlimited cycles for standard solar useservice.sungrowpower.com.ausungrowpower.com
End-of-warranty retained capacity (%)Published
70service.sungrowpower.com.ausungrowpower.com
exact_configurationPublished
SBR096 with three modules and 9.6 kWh usable is the audited reference.info-support.sungrowpower.com
usable_energy_basisPublished
The exact Australian product material publishes up to 100% usable energy and supports two to eight modules per tower.info-support.sungrowpower.comsungrowpower.com
round_trip_efficiencyReviewed absence
No comparable battery round-trip efficiency is published in the reviewed exact datasheet and warranty set.info-support.sungrowpower.comservice.sungrowpower.com.au
power_basisPublished
SBR096 publishes 5.76 kW battery-side continuous output; AC backup output and transfer require a named inverter.info-support.sungrowpower.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.info-support.sungrowpower.com
Open the complete scorecard
Lynx Home F G2GoodWe · AU priority 814Published4Reviewed absence0Not applicable0Open
Usable energy / DoD (%)Published
100goodwe.com.au
Round-trip efficiency (%)Published
94goodwe.com.au
Continuous power output (kW)Published
4.48goodwe.com.au
Operating temperature rangePublished
Standardgoodwe.com.au
Thermal & fire mitigationPublished
Passive thermal mgmtgoodwe.com.au
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedgoodwe.com.au
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedgoodwe.com.au
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldgoodwe.com.au
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedgoodwe.com.au
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termgoodwe.com.augoodwe.com.au
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablegoodwe.com.augoodwe.com.au
End-of-warranty retained capacity (%)Published
70goodwe.com.augoodwe.com.au
exact_configurationPublished
LX F6.4-H-20 with two LX F3.2-20 modules and 6.4 kWh usable is the audited reference.goodwe.com.au
usable_energy_basisPublished
The exact Australian datasheet publishes 6.4 kWh rated and usable at 100% depth of discharge, 0.2C and 25 C.goodwe.com.au
round_trip_efficiency_dcPublished
The exact datasheet publishes 94% battery round-trip efficiency; no AC system boundary is claimed.goodwe.com.au
cycle_life_basisPublished
The exact datasheet publishes more than 4,000 cycles to 80% end of life at 25 C and 0.7C; it must not be relabelled as a test to 70%.goodwe.com.au
operating_deratingPublished
Charge is 0 C to 50 C, discharge is -20 C to 50 C, and power derates with temperature and state of charge.goodwe.com.au
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.goodwe.com.au
Open the complete scorecard
Battery-Box Premium HVMBYD · AU priority 913Published4Reviewed absence1Not applicable0Open
Usable energy / DoD (%)Published
100bydbatterybox.combydbatterybox.com
Round-trip efficiency (%)Published
96bydbatterybox.combydbatterybox.com
Continuous power output (kW)Published
7.65bydbatterybox.combydbatterybox.com
Operating temperature rangePublished
Standardbydbatterybox.combydbatterybox.com
Thermal & fire mitigationPublished
Passive thermal mgmtbydbatterybox.combydbatterybox.com
Cell provenance & traceabilityPublished
In-housebydbatterybox.com
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedbydbatterybox.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldbydbatterybox.combydbatterybox.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedbydbatterybox.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termbydbatterybox.combydbatterybox.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablebydbatterybox.com
End-of-warranty retained capacity (%)Published
70bydbatterybox.com
exact_configurationPublished
Battery-Box Premium HVM 8.3 with three HVM modules and 8.28 kWh usable is the audited reference.bydbatterybox.com
usable_energy_basisPublished
BYD publishes DC usable energy at 100% depth of discharge, 0.2C charge and discharge, and 25 C; system usable energy may vary with inverter brand.bydbatterybox.com
round_trip_efficiency_dcPublished
The exact Australian datasheet publishes at least 96% DC battery round-trip efficiency; this is not AC-to-battery-to-AC efficiency.bydbatterybox.com
ac_backup_behaviourNot applicable
AC output, transfer time and motor-start capability are not battery-module properties for this DC-coupled battery.bydbatterybox.com
cell_balancingReviewed absence
No active or passive cell-level balancing architecture was disclosed in the reviewed exact material.bydbatterybox.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.bydbatterybox.com
Open the complete scorecard
aPower XFranklinWH · AU priority 914Published2Reviewed absence0Not applicable2Open
Usable energy / DoD (%)Published
93.75franklinwh.com
Round-trip efficiency (%)Published
89franklinwh.com
Continuous power output (kW)Published
5franklinwh.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedfranklinwh.com
Thermal & fire mitigationPublished
Basicfranklinwh.comfranklinwh.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedfranklinwh.comfranklinwh.com
Cell balancing architectureOpen
Not established
Modularity & scalabilityPublished
Fully modular / stackable expandablefranklinwh.com
Verified reliabilityOpen
Not established
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termfranklinwh.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablefranklinwh.com
End-of-warranty retained capacity (%)Published
70franklinwh.com
exact_configurationPublished
aPower X-02-AU is the audited 15 kWh usable AC-coupled configuration.franklinwh.com
usable_energy_basisPublished
The exact Australian datasheet publishes 16 kWh rated capacity, 15 kWh usable energy and 93.75% depth of discharge.franklinwh.com
round_trip_efficiency_acPublished
The exact datasheet publishes 89% AC-to-battery-to-AC round-trip efficiency at 50% power and beginning of life.franklinwh.com
power_basisPublished
The exact datasheet publishes 5 kW continuous AC power and 10 kW for 10 seconds per aPower X.franklinwh.com
warranty_performancePublished
The exact datasheet publishes 60 MWh aggregate throughput; this is a contractual limit, not a cycle-life test result.franklinwh.comfranklinwh.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.franklinwh.com
Open the complete scorecard
PowerAll BTS 5KSOFAR · AU priority 913Published4Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
97.5sofarsolar.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
2.5sofarsolar.comsofarsolar.com
Operating temperature rangePublished
Standardsofarsolar.comsofarsolar.com
Thermal & fire mitigationPublished
Passive thermal mgmtsofarsolar.comsofarsolar.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsofarsolar.com
Cell balancing architecturePublished
Pack-level only / not disclosedsofarsolar.com
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldau.sofarsolar.comsofarsolar.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedsofarsolar.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termsofarsolar.comsofarsolar.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usablesofarsolar.com
End-of-warranty retained capacity (%)Published
70sofarsolar.comsofarsolar.com
exact_configurationPublished
One BTS 5K module with 5.12 kWh rated and 4.992 kWh usable is the audited reference.sofarsolar.comsofarsolar.com
usable_energy_basisPublished
The exact source set publishes 4.992 kWh usable from 5.12 kWh rated, equal to 97.5% depth of discharge.sofarsolar.com
round_trip_efficiencyReviewed absence
No comparable battery round-trip efficiency was published.sofarsolar.comsofarsolar.com
cell_balancingPublished
SOFAR publishes a pack-level energy optimiser, old/new pack mixing and active pack equalisation to 100% state of charge in two hours; this does not establish active cell-level energy recirculation.sofarsolar.com
thermal_fire_mitigationPublished
The exact product page publishes five layers of cell, module, isolation and system protection but does not publish onboard fire suppression.sofarsolar.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.sofarsolar.com
Open the complete scorecard
TSYS-HS51SolaX · AU priority 1114Published4Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
100au.solaxpower.comau.solaxpower.com
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
6.1au.solaxpower.comau.solaxpower.com
Operating temperature rangePublished
Wide (-20 to 50C+), heat-optimisedau.solaxpower.comau.solaxpower.com
Thermal & fire mitigationPublished
Passive thermal mgmtau.solaxpower.comau.solaxpower.com
Cell provenance & traceabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.solaxpower.com
Cell balancing architecturePublished
Pack-level only / not disclosedau.solaxpower.com
Modularity & scalabilityPublished
Fully modular / stackable expandableau.solaxpower.comau.solaxpower.com
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedau.solaxpower.com
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termau.solaxpower.comau.solaxpower.com
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableau.solaxpower.comau.solaxpower.com
End-of-warranty retained capacity (%)Published
70au.solaxpower.comau.solaxpower.com
exact_configurationPublished
T-HS10.2 with two 5.1 kWh modules is the audited reference.au.solaxpower.com
usable_energy_basisPublished
The exact Australian datasheet publishes 10.2 kWh nominal and usable at 100% depth of discharge.au.solaxpower.com
round_trip_efficiencyReviewed absence
No battery-only round-trip efficiency is published in the reviewed exact Australian datasheet.au.solaxpower.com
cycle_life_basisPublished
The exact datasheet publishes more than 6,000 cycles at 70% end of life, 25 C and 0.5C.au.solaxpower.com
cell_balancingPublished
The optimiser version publishes pack equalisation and old/new module mixing; active cell-level energy recirculation is not established.au.solaxpower.com
thermal_fire_mitigationPublished
The exact Australian product publishes aerosol fire suppression; no active liquid or forced-air thermal management is claimed.au.solaxpower.comau.solaxpower.com
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.au.solaxpower.com
Open the complete scorecard
Smart Battery S0iStore · AU priority 1213Published4Reviewed absence0Not applicable2Open
Usable energy / DoD (%)Published
100istore.net.auistore.net.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
2.5istore.net.au
Operating temperature rangePublished
Standardistore.net.auistore.net.au
Thermal & fire mitigationPublished
Passive thermal mgmtistore.net.auistore.net.au
Cell provenance & traceabilityPublished
Undisclosedistore.net.auistore.net.au
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedistore.net.au
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldistore.net.au
Verified reliabilityReviewed absence
Exact source reviewed; qualifying disclosure not publishedistore.net.au
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termistore.net.auistore.net.au
Warranty throughputPublished
2.5-5 MWh warranted per kWh usableistore.net.au
End-of-warranty retained capacity (%)Published
70istore.net.auistore.net.au
exact_configurationPublished
IS-BATT-5000-S0 with one 5 kWh module is the audited reference.istore.net.au
usable_energy_basisPublished
The current exact Australian page publishes 5 kWh usable at 100% depth of discharge for one module.istore.net.auistore.net.au
round_trip_efficiencyReviewed absence
The reviewed exact product, specification and warranty material do not publish a comparable battery round-trip efficiency.istore.net.auistore.net.auistore.net.au
power_basisPublished
The one-module reference publishes 2.5 kW continuous battery output and 3.5 kW peak for 10 seconds.istore.net.au
thermal_fire_mitigationPublished
The current exact Australian page publishes eight temperature sensors and an automatic fire extinguisher in each module, while cooling remains natural convection.istore.net.au
evidence_correctionOpen
The current source record's statement that integrated fire suppression is not claimed is superseded by the current exact product page.istore.net.auistore.net.au
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.istore.net.au
Open the complete scorecard
US5000BPylontech · AU priority 1313Published4Reviewed absence0Not applicable1Open
Usable energy / DoD (%)Published
95en.pylontech.com.cnpylontech.au
Round-trip efficiency (%)Open
Not established
Continuous power output (kW)Published
4.8pylontech.au
Operating temperature rangePublished
Standardpylontech.au
Thermal & fire mitigationPublished
Passive thermal mgmten.pylontech.com.cnpylontech.au
Cell provenance & traceabilityPublished
In-housepylontech.com.cnpylontech.au
Cell balancing architectureReviewed absence
Exact source reviewed; qualifying disclosure not publishedpylontech.au
Modularity & scalabilityPublished
Fully modular, ≤5 kWh increments, expandable in fieldpylontech.au
Verified reliabilityPublished
Not independently testedarena.gov.au
Warranty degradation guaranteePublished
End-point only: minimum capacity at end of warranty termen.pylontech.com.cnpylontech.au
Warranty throughputPublished
Throughput terms not publisheden.pylontech.com.cn
End-of-warranty retained capacity (%)Published
60en.pylontech.com.cnpylontech.au
exact_configurationPublished
One US5000 or US5000-B module with 4.8 kWh nominal and 4.56 kWh usable is the audited reference.en.pylontech.com.cn
usable_energy_basisPublished
The exact current specification publishes 4.56 kWh usable and 95% depth of discharge.en.pylontech.com.cn
round_trip_efficiencyReviewed absence
No comparable exact battery round-trip efficiency was published.en.pylontech.com.cn
cycle_life_basisPublished
The exact specification publishes more than 6,000 cycles; the endpoint and test basis must remain attached to the exact source wording rather than inferred from the headline.en.pylontech.com.cn
warranty_throughputReviewed absence
The governing Australian warranty publishes no energy-throughput allowance.en.pylontech.com.cn
standby_consumptionReviewed absence
No exact standby-consumption wattage was published.en.pylontech.com.cn