aPower X
FranklinWH
63/ 100
Strong evidence coverage · 100%
Evidence checked 2026-08-02
Available in Australia · checked 2026-08-02
Buyer evidence: Ready (100% direct coverage).
Compare like with like. Aligned scores, specifications and local evidence within one scoring class or tier.
Market context
Australia purchasing view
FranklinWH
63/ 100
Strong evidence coverage · 100%
Evidence checked 2026-08-02
Available in Australia · checked 2026-08-02
Buyer evidence: Ready (100% direct coverage).
Enphase
76/ 100
Strong evidence coverage · 100%
Evidence checked 2026-08-02
Available in Australia · checked 2026-08-02
Buyer evidence: Ready (100% direct coverage).
| Measure | aPower X | IQ Battery 5P |
|---|---|---|
| Capacity & Usability | ||
| Power & Efficiency | ||
| Longevity (verified) | ||
| Safety & Chemistry | ||
| Guarantee & Backbone | ||
| Energy Ecosystem |
| Measure | aPower X | IQ Battery 5P |
|---|---|---|
| Published usable capacity range | 15 kWh | 5 kWh |
| Chemistry | LFP | LFP |
| Power | 5 kW | 3.84 kW |
| Round-trip | 89 % | 96 % |
| Cycle life | Not recorded | Not recorded |
| Evidence | aPower X | IQ Battery 5P |
|---|---|---|
| Outcome | Available in Australia | Available in Australia |
| Checked | 2026-08-02 | 2026-08-02 |
| Certifications | The current Australian approved-battery export lists aPower X-02-AU with 16 kWh nominal and 15 kWh usable capacity, approved 12 May 2026 through 31 December 2027; the exact system datasheet publishes AS/NZS 4777.2:2020 compliance. | The AU/NZ IQ Battery 5P datasheet identifies IQBATTERY-5P-1P-ROW and IQBATTERY-5P-3P-INT and lists AS/NZS 4777.2:2020 + A2, AS IEC 62040.1, EN IEC 62109-1/-2, AS IEC 62619 and UN 38.3. |
| Warranty scope | Australia and New Zealand; 12 years or 60 MWh aggregate throughput for APR-05K15V1-AU, with at least 70% retained capacity and conditions covering authorised supply, certified installation, registration, internet connectivity and software updates. | Australia and New Zealand; 15 years or 6,000 discharged cycles for the IQ Battery 5P, subject to Enphase terms. |
| Warranty remedy | Repair, replacement with a new or refurbished equivalent, or a depreciated refund at FranklinWH's discretion. | Repair, replacement or another remedy under the published terms. |
| Labour and reinstallation | Installation labour is not promised. Removal and reinstallation are not promised. | Troubleshooting, removal and reinstallation labour are excluded. Removal and reinstallation are excluded. |
| Freight | Return shipping requires prior RMA authorisation; no broader unconditional freight entitlement is stated. | Eligible replacement shipping is covered. |
| Transfer and registration | The claim process accepts proof of subsequent transfers of ownership, but the limited warranty does not expressly promise automatic transfer. Registration at installation, continued internet connectivity and software updates are required for the full 12-year term; otherwise coverage can reduce to four years. | Transfers at the original site after a change-of-ownership form and fee are completed within 30 days. Change of ownership must be notified within 30 days; gateway activation conditions also apply. |
| Grid compatibility | The exact 230/240 V, 50 Hz AC-coupled aPower X-02-AU system publishes AS/NZS 4777.2 compliance and supports one-, two- and three-phase configurations through aGate; final DNSP approval remains installation-specific. | Backup capability requires an IQ System Controller 3 INT; Enphase certification is required to commission the system. |
| System fit | No exact product pairing recorded | No exact product pairing recorded |
| Local product pathway | No separate local pathway recorded | No separate local pathway recorded |
| Buyer evidence | Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed. | Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed. |
| Safety notice | No model-specific notice recorded | No model-specific notice recorded |
| Review note | FranklinWH Australia identifies APR-05K15V1-AU as the only current Australian aPower model and publishes local service contact details in Macquarie Park, New South Wales. | Enphase publishes an AU product page, local warranty, and installer requirements for this exact SKU family. |
| Sources | Source 1Source 2Source 3Source 4 | Source 1Source 2Source 3Source 4 |
These checks sit beside the benchmark score. They are site, tariff and contract questions that no product score can settle.
Ask for every model number to appear on the quote and order. The Clean Energy Council product lists are live: STC creation requires listed products at installation, and network requirements may also depend on current approval.
Have the retailer state the supply phase, inverter connection limit, export limit and any export-control cost. The local network connection agreement, not a generic datasheet, determines those settings. See the Australian Government's connection guidance.
Ask which bills or interval data, tariff, feed-in rate, export limit and future loads support the savings and payback claim. Self-consumed electricity and tariff timing usually matter more than a headline feed-in rate. See the system sizing and battery savings guidance.
Define the usable energy, output power, backed-up circuits and outage behaviour. Confirm whether VPP participation, an internet connection, or an additional controller changes the configuration, reserve level, warranty or support path.
Keep the retailer, installer, manufacturer warranty and escalation path in the contract. Australian Consumer Law guarantees apply separately from any manufacturer warranty; where one business supplied both product and installation, it is generally responsible for the remedy. See the ACCC guidance.
A score lead is only meaningful inside this shared class or tier. Weigh it against the specification and evidence rows above before deciding.
Both products are scored in the Premium Integrated class, on the same rubric weighting. Scores are not comparable across classes or tiers. Full methodology.