Side-by-side

Compare

Compare like with like. Aligned scores, specifications and local evidence within one scoring class or tier.

Market context

Germany purchasing view

Inverter

Power Storage DC6–9.9 kW

RCT Power | Power Storage DC 6.0 / 8.0 / 10.0; scored DC 10.0 at 9.9 kW

Three-phaseHybrid2 MPPTs

60/ 100

Good

Strong evidence coverage · 100%

Evidence checked 2026-09-01

Available in Germany · checked 2026-08-16

Buyer evidence: Ready (100% direct coverage).

Full scorecard
Inverter

IQ9N-A Microinverter0.427 kW

Enphase | IQ9N-A-INT; 427 VA exact Australian model

Single-phaseMicroinverter

63/ 100

Good

Strong evidence coverage · 100%

Evidence checked 2026-08-30

Available in Germany · checked 2026-08-30

Buyer evidence: Ready (100% direct coverage).

Fanless DesignIP67 Rated25-Year WarrantyMicroinverter
Full scorecard
Side by side

Score profile

marks the better value on rows where a higher number is better. Temperature coefficient counts as higher when it is closer to zero. Size measures such as rated power carry no marker, because a larger product is a different choice rather than a better one.

MeasurePower Storage DCIQ9N-A Microinverter
Efficiency80 / 100 (better value on this row)60 / 100
Design & Flexibility71 / 10054 / 100
Thermal & Physical Resilience47 / 10086 / 100
Features & Integration64 / 10053 / 100
Safety & Compliance70 / 10078 / 100
Guarantee & Backbone50 / 10060 / 100
Energy Ecosystem40 / 10040 / 100

Efficiency

Power Storage DC
80 / 100 (better value on this row)
IQ9N-A Microinverter
60 / 100

Design & Flexibility

Power Storage DC
71 / 100
IQ9N-A Microinverter
54 / 100

Thermal & Physical Resilience

Power Storage DC
47 / 100
IQ9N-A Microinverter
86 / 100

Features & Integration

Power Storage DC
64 / 100
IQ9N-A Microinverter
53 / 100

Safety & Compliance

Power Storage DC
70 / 100
IQ9N-A Microinverter
78 / 100

Guarantee & Backbone

Power Storage DC
50 / 100
IQ9N-A Microinverter
60 / 100

Energy Ecosystem

Power Storage DC
40 / 100
IQ9N-A Microinverter
40 / 100
Side by side

Key specifications

marks the better value on rows where a higher number is better. Temperature coefficient counts as higher when it is closer to zero. Size measures such as rated power carry no marker, because a larger product is a different choice rather than a better one.

MeasurePower Storage DCIQ9N-A Microinverter
ArchitectureHybrid inverterMicroinverter
Published rated AC power range6–9.9 kW0.427 kW
Scored benchmark9.9 kWNot stated
Power9.9 kW0.427 kW
TypeHybridMicro
Peak eff98.6 %Not recorded
MPPTs2 (better value on this row)1

Architecture

Power Storage DC
Hybrid inverter
IQ9N-A Microinverter
Microinverter

Published rated AC power range

Power Storage DC
6–9.9 kW
IQ9N-A Microinverter
0.427 kW

Scored benchmark

Power Storage DC
9.9 kW
IQ9N-A Microinverter
Not stated

Power

Power Storage DC
9.9 kW
IQ9N-A Microinverter
0.427 kW

Type

Power Storage DC
Hybrid
IQ9N-A Microinverter
Micro

Peak eff

Power Storage DC
98.6 %
IQ9N-A Microinverter
Not recorded

MPPTs

Power Storage DC
2 (better value on this row)
IQ9N-A Microinverter
1
Local evidence

Germany evidence

EvidencePower Storage DCIQ9N-A Microinverter
OutcomeAvailable in GermanyAvailable in Germany
Checked2026-08-162026-08-30
CertificationsDC 6.0 has VDE-AR-N 4105 certificates U20-0978/U20-0980; DC 8.0 and 10.0 have U20-0672/U20-0676, with firmware 2.3 or later.The German store page names SKU IQ9N-A-INT and 427 VA. The IQ9N-A-INT sheet lists EN IEC 62109-1/-2 safety and CE labelling.
Warranty scopeGermany; ten years from purchase, capped at 123 months after factory dispatch, with stated exchange-process exclusions.Germany; the 30 September 2025 German microinverter schedule explicitly lists IQ9N-A-INT for a 25-year product term from activation.
Warranty remedyRCT may supply an equivalent refurbished replacement under its exchange process.Enphase may repair, replace or provide a depreciated market-value refund.
Labour and reinstallationAn installer allowance may apply, but travel and onsite installation are excluded. Removal and reinstallation are excluded.Uninstall, reinstall and ordinary site labour are not limited-warranty entitlements. Removal and reinstallation are excluded from the limited warranty.
FreightReturn freight may be reimbursed through the exchange process.Eligible RMA return freight uses Enphase's prepaid label. Enphase pays shipment of the repaired or replacement product after an accepted claim.
Transfer and registrationAn unrestricted later-owner transfer right was not established. Purchase date, factory dispatch limit, serial identity and claim process control coverage.Same-site transfer requires the owner-change form and fee within 30 days. Covered SKUs must match the German schedule. Continuous internet connectivity is required except for interruptions outside the owner's reasonable control.
Grid/network approval evidenceCurrent German DC 6.0, 8.0 and 10.0 family. DC 4.0 and legacy DC 5.0 remain outside this exact scored identity.The reviewed IQ9N-A-INT sheet prints grid compliance as AS/NZS 4777.2 and does not print VDE-AR-N 4105. German connection approval remains installation-specific.
Local product pathwayNo separate local pathway recordedNo separate local pathway recorded
Buyer evidenceReady (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed.Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed.
Safety noticeNo model-specific notice recordedNo model-specific notice recorded
Review noteThe current exact datasheet begins at DC 6.0. Nearby 4.0 and legacy 5.0 references are not silently absorbed.Enphase's German store lists IQ9N-A-INT. IQ9N-A-DOM-US is a different SKU and is not this record. The INT sheet remains the specification source; distributor stock is not inferred.
SourcesSource 1Source 2Source 3Source 1Source 2Source 3Source 4

Outcome

Power Storage DC
Available in Germany
IQ9N-A Microinverter
Available in Germany

Checked

Power Storage DC
2026-08-16
IQ9N-A Microinverter
2026-08-30

Certifications

Power Storage DC
DC 6.0 has VDE-AR-N 4105 certificates U20-0978/U20-0980; DC 8.0 and 10.0 have U20-0672/U20-0676, with firmware 2.3 or later.
IQ9N-A Microinverter
The German store page names SKU IQ9N-A-INT and 427 VA. The IQ9N-A-INT sheet lists EN IEC 62109-1/-2 safety and CE labelling.

Warranty scope

Power Storage DC
Germany; ten years from purchase, capped at 123 months after factory dispatch, with stated exchange-process exclusions.
IQ9N-A Microinverter
Germany; the 30 September 2025 German microinverter schedule explicitly lists IQ9N-A-INT for a 25-year product term from activation.

Warranty remedy

Power Storage DC
RCT may supply an equivalent refurbished replacement under its exchange process.
IQ9N-A Microinverter
Enphase may repair, replace or provide a depreciated market-value refund.

Labour and reinstallation

Power Storage DC
An installer allowance may apply, but travel and onsite installation are excluded. Removal and reinstallation are excluded.
IQ9N-A Microinverter
Uninstall, reinstall and ordinary site labour are not limited-warranty entitlements. Removal and reinstallation are excluded from the limited warranty.

Freight

Power Storage DC
Return freight may be reimbursed through the exchange process.
IQ9N-A Microinverter
Eligible RMA return freight uses Enphase's prepaid label. Enphase pays shipment of the repaired or replacement product after an accepted claim.

Transfer and registration

Power Storage DC
An unrestricted later-owner transfer right was not established. Purchase date, factory dispatch limit, serial identity and claim process control coverage.
IQ9N-A Microinverter
Same-site transfer requires the owner-change form and fee within 30 days. Covered SKUs must match the German schedule. Continuous internet connectivity is required except for interruptions outside the owner's reasonable control.

Grid/network approval evidence

Power Storage DC
Current German DC 6.0, 8.0 and 10.0 family. DC 4.0 and legacy DC 5.0 remain outside this exact scored identity.
IQ9N-A Microinverter
The reviewed IQ9N-A-INT sheet prints grid compliance as AS/NZS 4777.2 and does not print VDE-AR-N 4105. German connection approval remains installation-specific.

Local product pathway

Power Storage DC
No separate local pathway recorded
IQ9N-A Microinverter
No separate local pathway recorded

Buyer evidence

Power Storage DC
Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed.
IQ9N-A Microinverter
Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed.

Safety notice

Power Storage DC
No model-specific notice recorded
IQ9N-A Microinverter
No model-specific notice recorded

Review note

Power Storage DC
The current exact datasheet begins at DC 6.0. Nearby 4.0 and legacy 5.0 references are not silently absorbed.
IQ9N-A Microinverter
Enphase's German store lists IQ9N-A-INT. IQ9N-A-DOM-US is a different SKU and is not this record. The INT sheet remains the specification source; distributor stock is not inferred.

Sources

Power Storage DC
Source 1Source 2Source 3
Decision snapshot

Where the comparison separates

OverallIQ9N-A Microinverter leads the global score by 3 points.
Strongest dimensionsPower Storage DC: Efficiency · IQ9N-A Microinverter: Thermal & Physical Resilience
Largest differenceIQ9N-A Microinverter has the largest pillar edge in Thermal & Physical Resilience (39 points).
Market evidencePower Storage DC: buyer ready · IQ9N-A Microinverter: buyer ready

A score lead is only meaningful inside this shared class or tier. Weigh it against the specification and evidence rows above before deciding.

Both products are scored in the Inverter class, on the same rubric weighting. Scores are not comparable across classes or tiers. Full methodology.