back to inverters

PLACEHOLDERNot a representation of the product
Inverter

SG20RT-P2

15–20 kW · String · Three-phase · 2 MPPTs

Sungrow

69/ 100

Very good

Global

AFCI Integrated

The verdict. In our Inverter class, Sungrow SG20RT-P2 leads on safety & compliance.

43thof 63 in InverterLower halfclass average 70.5
Compare this inverter →Ask Watt →
Check the P2 communication module and connection arrangement. SG20RT-P2 has its own entry in the published Modbus protocol. Direct RS485 access uses Modbus RTU; Ethernet Modbus TCP depends on supported communication hardware. The India-linked manual explicitly includes SG20RT-P2 and describes WiNet-S for the P2 route, separately from WiNet-S2 for the earlier RT route. Ethernet through the communication module cannot be used at the same time as the A1/B1 RS485 daisy chain. The general protocol excludes iHomeManager and other communication modules from its documented route. The manual connects this inverter to iSolarCloud, whose cloud monitoring API needs developer and application approval, plant authorization, connectivity and the applicable service package. Cloud monitoring does not establish a local REST API, SunSpec certification, a named live VPP or every cloud dispatch command for SG20RT-P2. Confirm the supplied P2 hardware, module, firmware and permitted connection arrangement before connecting another controller. Source 1.Source 2.Source 3.

The assessment

How it scores, by category

Efficiency71
Design & Flexibility83
Thermal & Physical Resilience71
Features & Integration53
Safety & Compliance89
Guarantee & Backbone62
Energy Ecosystem50

Market position

43thof 63 in InverterLower half
566982

Our reading

SG20RT-P2 scores 69, placing 43 of 63 in the Inverter class against a class average of 70.5. Its strongest scoring dimension is safety & compliance (89), running 10.7 points above the class average on this dimension. Energy Ecosystem (50) is the dimension with the most room to move. Key specifications: 98.3% peak efficiency, 2 MPPT inputs, 5-year warranty.

The data

Power
20.0kW
Type
String
Peak eff
98.3%
MPPTs
2
Technology architecture

Solar-only string inverter

Architecture guide

Converts PV string DC into grid-connected AC.

Product role
No native battery conversion path is recorded for the product.
Published range
15–20 kW
Phase
Three phase
Backup boundary
No native backup recorded
Architecture describes the product boundary. It is not a system design or an equipment-pairing decision.

Warranty coverage: 5-year term

Coverage includes

✓Parts
–Labour
–Extendable
Market typical5yr0yr5yr10yr15yr20yr25yr

Parts only · term longer than 0 of 95 scored inverters

No inverter in the fleet publishes a year-by-year performance or output guarantee the way panels and batteries do - this shows the covered term against the market-typical term and where every scored inverter’s term lands (grey dots, sized by model count), plus what the warranty actually includes.

Before you buy
Local positionUse a market view to check local availability, approvals and warranty scope.
Ask the installerWill the exact SG20RT-P2 model satisfy the site phase, array, MPPT, export-control and local grid requirements?

Verification & sources

Market context

Global evidencechange in the site menu

Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.

Benchmark anchor. The score uses the highest exact current power bin named on the V2 sheet linked from Sungrow India's SG15/20RT-P2 card. SG12RT on sungrow_sg_rt.json is a different identity. Scored model: SG20RT-P2 · checked 2026-09-03. Evidence.

Sources & references · checked 2026-09-05

Strong evidence coverage

25 of 25 scored criteria link directly to a published source.

Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.

Record revision. Sungrow SG15/17/20RT-P2 datasheet Version 2 linked from the India SG15/20RT-P2 page. India inverter and battery warranty-terms recovery 2026-09-05: structured IN overlay terms recovered or held from the current Indian governing instrument.

Help strengthen this record

These are published evidence gaps, not private submissions. A source is reviewed under the same methodology whether it comes from a reader, installer or manufacturer.

View the open evidence register
Change ledger

Product record history

4 changes to this record · 8 products changed in this update
  1. Record updated

    Global score

    Before
    69.4
    After
    68.8
    Primary datasheet
  2. Record updated

    Grid & safety certification

    Before
    IEC 62109 + grid codes, 3+ markets
    After
    IEC 62109 + grid codes, 2 markets
    Grid & safety certificationGrid & safety certification+3 in JSON record
  3. Record updated

    Safety & Compliance pillar score

    Before
    94.6
    After
    89.1
    Primary datasheet
  4. Record updated

    Grid & safety certification: Evidence sources

    Before
    https://info-support.sungrowpower.com/application/pdf/2023/11/24/DS_20231113_SG15_17_20RT-P2_Datasheet_V2_EN.pdf
    After
    https://hybrid.connect-direct.energynetworks.org/lct/v1/ttr-search; https://info-support.sungrowpower.com/application/pdf/2023/11/24/DS_20231113_SG15_17_20RT-P2_Datasheet_V2_EN.pdf; https://www.certipedia.com/certificates/50485651?locale=en&page_number=6; https://www.synergrid.be/images/downloads/GLV070-16_Sungrow_SGxxRT-P2_20240705_final.pdf; https://www.synergrid.be/images/downloads/c10_26_list_of_pgu_compliant_with_c10_11_ed2_1_12_2019.xlsx
    Grid & safety certificationGrid & safety certification+3 in JSON record
8 changes to this record · 1 product changed in this update
  1. Evidence added

    Summary

    Before
    Not previously recorded
    After
    SG20RT-P2 has its own entry in the published Modbus protocol. Direct RS485 access uses Modbus RTU; Ethernet Modbus TCP depends on supported communication hardware. The India-linked manual explicitly includes SG20RT-P2 and describes WiNet-S for the P2 route, separately from WiNet-S2 for the earlier RT route. Ethernet through the communication module cannot be used at the same time as the A1/B1 RS485 daisy chain. The general protocol excludes iHomeManager and other communication modules from its documented route. The manual connects this inverter to iSolarCloud, whose cloud monitoring API needs developer and application approval, plant authorization, connectivity and the applicable service package. Cloud monitoring does not establish a local REST API, SunSpec certification, a named live VPP or every cloud dispatch command for SG20RT-P2. Confirm the supplied P2 hardware, module, firmware and permitted connection arrangement before connecting another controller.
    Primary datasheet
  2. Record updated

    Global score

    Before
    68.3
    After
    69.4
    Primary datasheet
  3. Record updated

    Open protocol & API maturity

    Before
    Proprietary / no documented API
    After
    Modbus TCP + cloud API
    Open protocol & API maturityOpen protocol & API maturity+3 in JSON record
  4. Record updated

    Open protocol & API maturity: Evidence status

    Before
    reviewed_absence
    After
    sourced
    Open protocol & API maturityOpen protocol & API maturity+3 in JSON record
  5. Record updated

    Open protocol & API maturity: Evidence sources

    Before
    https://info-support.sungrowpower.com/application/pdf/2023/11/24/DS_20231113_SG15_17_20RT-P2_Datasheet_V2_EN.pdf; https://www.sungrowpower.com/in/en/product/string-inverter/sgrt-15-17-20-p2
    After
    https://developer-api.isolarcloud.com/; https://info-support.sungrowpower.com/cms/af994f1d-bb0d-408a-b310-6ad732402c99/GUID-6569C825-A19E-496C-B2E0-67A3422BEACF_1_en-US_PDF%20(%E4%BA%A7%E5%93%81%E4%BF%A1%E6%81%AF%E8%AE%BE%E8%AE%A1%E9%83%A8_%E5%9F%BA%E7%A1%80%E7%89%88)_1782713320715_compressed.pdf; https://info-support.sungrowpower.com/general-material/85cf50fa-188e-4b23-8a42-606482297b41.pdf
    Open protocol & API maturityOpen protocol & API maturity+3 in JSON record
  6. Evidence added

    Title

    Before
    Not previously recorded
    After
    Check the P2 communication module and connection arrangement
    Primary datasheet
  7. Evidence added

    Evidence sources

    Before
    Not previously recorded
    After
    https://developer-api.isolarcloud.com/; https://info-support.sungrowpower.com/cms/af994f1d-bb0d-408a-b310-6ad732402c99/GUID-6569C825-A19E-496C-B2E0-67A3422BEACF_1_en-US_PDF%20(%E4%BA%A7%E5%93%81%E4%BF%A1%E6%81%AF%E8%AE%BE%E8%AE%A1%E9%83%A8_%E5%9F%BA%E7%A1%80%E7%89%88)_1782713320715_compressed.pdf; https://info-support.sungrowpower.com/general-material/85cf50fa-188e-4b23-8a42-606482297b41.pdf
    Primary datasheet
  8. Record updated

    Energy Ecosystem pillar score

    Before
    41.5
    After
    50.5
    Primary datasheet
4 changes to this record · 8 products changed in this update
  1. Evidence added

    IN Warranty conditions

    Before
    Not previously recorded
    After
    labour: Sungrow does not bear labour costs for removing the defective product or reinstalling the repaired or replacement product. In-warranty cover is materials only (clause 7.3).; registration: No baseline pre-install registration deadline is stated. Cover starts from the invoice date or documented first installation, or six months after Sungrow factory shipment if both documents are missing. Claims need proof of purchase, serial number and a defect report via phone, email or Sungrow GSP (clauses 2.2, 6.1 and 6.2).; remedy: Sungrow supplies the materials needed for repair (replacement parts or an equivalent replacement). If the product is not repairable, Sungrow may supply a new or refurbished replacement of equal or higher performance. Remaining term follows the replacement (clauses 3.1 and 3.3).; removal reinstallation: Sungrow does not cover removal, reinstallation, or troubleshooting of other electrical-system components. Relocation to a new site needs Sungrow's written consent and a paid on-site inspection (clauses 3.7, 5.1(j), 7.3 and 7.4).; transferability: Warranty rights may transfer to a later owner, authorised operator or lessee at the same site during the warranty period. The new end-user must sign and submit Sungrow's warranty transfer agreement (clause 3.6).; transport: The claimant bears freight of the alleged defective product back to Sungrow. Sungrow bears freight of the new or refurbished product to the end-user. Shipping damage is excluded (clauses 7.1 to 7.3).
    IN market evidenceWarranty period (yrs)+4 in JSON record
  2. Record updated

    IN Evidence sources

    Before
    https://info-support.sungrowpower.com/application/pdf/2023/11/24/DS_20231113_SG15_17_20RT-P2_Datasheet_V2_EN.pdf; https://sungrowtest2blob.blob.core.windows.net/sungrow-official-web-dev/page-assets/60805b20-5f6a-4486-ae7f-37b8da26b4e7.png; https://www.sungrowpower.com/in/en/product/string-inverter/sgrt-15-17-20-p2; https://www.sungrowpower.com/in/en/products/string-inverter; https://www.sungrowpower.com/in/en/warranty-terms-and-conditionsdetail-global-site
    After
    https://info-support.sungrowpower.com/application/pdf/2023/11/24/DS_20231113_SG15_17_20RT-P2_Datasheet_V2_EN.pdf; https://sungrowtest2blob.blob.core.windows.net/sungrow-official-web-dev/page-assets/60805b20-5f6a-4486-ae7f-37b8da26b4e7.png; https://www.sungrowpower.com/in/en/product/string-inverter/sgrt-15-17-20-p2; https://www.sungrowpower.com/in/en/products/string-inverter; https://www.sungrowpower.com/in/en/warranty-terms-and-conditions-country-list-global-site; https://www.sungrowpower.com/in/en/warranty-terms-and-conditionsdetail-global-site
    IN market evidenceWarranty period (yrs)+4 in JSON record
  3. Record updated

    IN Warranty scope

    Current text
    India; the India manufacturer warranty HTML on sungrowpower.com/in/en, with the 2.3 product-list image, lists Residential Inverter (1-phase and 3-phase) at 5 years standard, with paid extension to 10 years. The instrument does not name SG20RT-P2. Six structured warranty terms are recovered from clauses 3, 6 and 7 of that India HTML. AU, US or DE terms are not transferred.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    IN market evidenceWarranty period (yrs)+4 in JSON record
  4. Record updated

    Source revision

    Before
    Sungrow SG15/17/20RT-P2 datasheet Version 2 linked from the India SG15/20RT-P2 page.
    After
    Sungrow SG15/17/20RT-P2 datasheet Version 2 linked from the India SG15/20RT-P2 page. India inverter and battery warranty-terms recovery 2026-09-05: structured IN overlay terms recovered or held from the current Indian governing instrument.
    Primary datasheet
1 change to this record · 5 products changed in this update
  1. Record added

    Product record

    kind: inverter; brand: Sungrow; name: SG20RT-P2; model: Current India-listed SG15/17/20RT-P2 family; scored model SG20RT-P2; score: 68.3

    Primary datasheet

This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.

Evidence timeline

Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.

  1. Core scorecard evidence checked
  2. IN market evidence checked
  3. Series benchmark evidence checked

Evidence record (JSON)

Scored by Solar Analytica Research

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.