SUN2000-30KTL-M3
30 kW · String · Three-phase · 6 MPPTs
Huawei
Value & Volume
Released 2022 · Evidence checked 2026-06-20 · Scored to Solar Analytica inverter rubric v3.6.0
74/100
Very good
Overall
Score by category
Efficiency
75
Design & Flexibility
79
Thermal & Physical Resilience
82
Features & Integration
60
Safety & Compliance
80
Guarantee & Backbone
74
Energy Ecosystem
69
Sourced specification values
Published power range30 kW
Scored benchmark30 kW
Rated AC power30 kW
Phases3-phase
Peak efficiency98.8%
Weighted efficiency98.5%
Number of MPPTs6
Max input current / MPPT20 A
Ingress protectionIP65
Warranty period10 yr
Grid & safety certificationIEC 62109 + national grid codes certified for 3+ markets
Manufacturing track record15+ years, field-proven

Some values are estimated where independent verification was not available: see the full scorecard and review.solar/terms.

Page 2 · Audit sheet: complete sourced record (1 of 2)

SUN2000-30KTL-M3 · every criterion scored by the live rubric (Solar Analytica inverter rubric v3.6.0), with its recorded value, evidence status, and any linked source. Page 1 carries the buying-decision summary; this and the next page are the full record for verification and right of reply.

Efficiency
Peak efficiency (%)98.8est.No link
Weighted efficiency (CEC/Euro %)98.5est.No link
Semiconductor technologyIGBT / MOSFET (standard silicon)est.No link
Night standby consumption (W)5.5statedSource
Design & Flexibility
Number of MPPTs6est.No link
Max DC:AC oversizing ratio1.5est.No link
Max input current per MPPT (A)20est.No link
Thermal & Physical Resilience
Thermal managementSmart active cooling (<30dB, load/temp-triggered)est.No link
Ingress protectionIP65statedNo link
Operating temperature rangeStandardstatedNo link
Surge protectionType II DC + AC SPDest.No link
Features & Integration
Hybrid / battery capabilityString onlystatedNo link
Backup / islandingNo backupstatedNo link
Monitoring & smart featuresApp + smart featuresstatedNo link
Reactive power range±0.8 pf leading/lagging: Q(U) + Q(P) four-quadrant responsestatedNo link

review.solar · audit sheet · Solar Analytica inverter rubric v3.6.0 · https://review.solar/cards/huawei-technologies-co-ltd-huawei-digital-power-huawei-sun20

Page 3 · Audit sheet: complete sourced record (2 of 2)

SUN2000-30KTL-M3 · continued from page 2 · Solar Analytica rubric Solar Analytica inverter rubric v3.6.0.

Safety & Compliance
Grid & safety certificationIEC 62109 + grid codes, 3+ marketsstatedSource
Shutdown / arc safetyStringstatedNo link
Guarantee & Backbone
Warranty period (yrs)10statedNo link
Warranty assuranceParts onlystatedNo link
Financial strength & warranty backingFinancially strong (profitable / strong parent)est.No link
Manufacturing track record15+ years, field-provenstatedNo link
Energy Ecosystem
Open protocol & API maturityCloud API onlyest.No link
VPP & grid services readinessVPP-capable + live VPP program (named market)est.No link
EV charging integrationNo EV integrationest.No link
Thermal load managementNative SG-Ready or direct heat pump protocol integrationest.No link
Smart home & IoT depthGateway hub integration (20+ devices)est.No link
Firmware & security disclosureVulnerability disclosure policy + firmware/security documentation publishedstatedSource +5