Side-by-side

Compare

Compare like with like. Aligned scores, specifications and local evidence within one scoring class or tier.

Market context

Australia purchasing view

Microinverter

IQ8HC0.384 kW

Enphase | IQ8HC-72-M-INT

Single-phaseMicroinverter

71/ 100

Very good

Strong evidence coverage · 88%

Evidence checked 2026-08-06

Available in Australia · checked 2026-08-06

Buyer evidence: Ready (88% direct coverage).

Fanless DesignIP67 Rated25-Year WarrantyMicroinverter
Full scorecard
Microinverter

IQ8AC0.366 kW

Enphase | IQ8AC-72-M-INT

Single-phaseMicroinverter

68/ 100

Very good

Strong evidence coverage · 100%

Evidence checked 2026-08-06

Available in Australia · checked 2026-08-02

Buyer evidence: Ready (100% direct coverage).

Fanless DesignIP67 Rated25-Year WarrantyMicroinverter
Full scorecard
Side by side

Score profile

MeasureIQ8HCIQ8AC
Efficiency61 / 10061 / 100
Design & Flexibility50 / 10050 / 100
Thermal & Physical Resilience86 / 10086 / 100
Features & Integration65 / 10065 / 100
Safety & Compliance90 / 10090 / 100
Guarantee & Backbone86 / 10060 / 100
Energy Ecosystem57 / 10059 / 100

Efficiency

IQ8HC
61 / 100
IQ8AC
61 / 100

Design & Flexibility

IQ8HC
50 / 100
IQ8AC
50 / 100

Thermal & Physical Resilience

IQ8HC
86 / 100
IQ8AC
86 / 100

Features & Integration

IQ8HC
65 / 100
IQ8AC
65 / 100

Safety & Compliance

IQ8HC
90 / 100
IQ8AC
90 / 100

Guarantee & Backbone

IQ8HC
86 / 100
IQ8AC
60 / 100

Energy Ecosystem

IQ8HC
57 / 100
IQ8AC
59 / 100
Side by side

Key specifications

marks the better value on rows where a higher number is better. Temperature coefficient counts as higher when it is closer to zero. Size measures such as rated power carry no marker, because a larger product is a different choice rather than a better one.

MeasureIQ8HCIQ8AC
ArchitectureMicroinverterMicroinverter
Published rated AC power range0.384 kWNot stated
Power0.384 kW0.366 kW
TypeMicroMicro
Peak eff97.4 % (better value on this row)97.3 %
MPPTs11
Published maximum AC output rangeNot stated0.366 kW

Architecture

IQ8HC
Microinverter
IQ8AC
Microinverter

Published rated AC power range

IQ8HC
0.384 kW
IQ8AC
Not stated

Power

IQ8HC
0.384 kW
IQ8AC
0.366 kW

Type

IQ8HC
Micro
IQ8AC
Micro

Peak eff

IQ8HC
97.4 % (better value on this row)
IQ8AC
97.3 %

MPPTs

IQ8HC
1
IQ8AC
1

Published maximum AC output range

IQ8HC
Not stated
IQ8AC
0.366 kW
Local evidence

Australia evidence

EvidenceIQ8HCIQ8AC
OutcomeAvailable in AustraliaAvailable in Australia
Checked2026-08-062026-08-02
CertificationsAS/NZS 4777.2:2020 + A2, EN IEC 62109-1, EN IEC 62109-2 and RCM for IQ8HC-72-M-INT.The exact Australian datasheet publishes AS/NZS 4777.2:2020 + A2, EN IEC 62109-1/-2 and RCM compliance.
Warranty scopeAustralia and New Zealand; the current terms provide 25 years for eligible IQ8HC-72-M-INT units, subject to activation and claim conditions.Australia and New Zealand; Enphase publishes a 25-year limited warranty for eligible IQ8-series microinverters when the stated IQ Gateway and activation conditions are met.
Warranty remedyRepair, replacement or depreciated refund at Enphase's option.Repair, replacement or depreciated refund at Enphase's option.
Labour and reinstallationUninstall and reinstallation labour are excluded from the product warranty. Removal and reinstallation are excluded; a separate installer program is conditional and shorter.Uninstall and reinstallation labour are excluded from the product warranty. Removal and reinstallation are excluded; a separate installer program is conditional and shorter.
FreightEligible RMA and replacement freight is covered.Eligible RMA and replacement freight is covered.
Transfer and registrationTransfers at the original site after the ownership form, fee and notice are completed within 30 days. Ownership change must be notified within 30 days; gateway activation conditions apply.Transfers at the original site after the ownership form, fee and notice are completed within 30 days. Ownership change must be notified within 30 days; gateway activation conditions apply.
Grid compatibilityIQ8HC-72-M-INT is the 230 V, 50 Hz Australian SKU and publishes AS/NZS 4777.2:2020 + A2 compliance with IQ Relay.230 V IQ8AC-72-M-INT with AS/NZS 4777.2 compliance through the required IQ Relay.
Local product pathwayNo separate local pathway recordedNo separate local pathway recorded
Buyer evidenceReady (88% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed.Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed.
Safety noticeNo model-specific notice recordedNo model-specific notice recorded
Review noteEnphase publishes the exact Australian store SKU, datasheet, certification records and locally scoped warranty documentation.Enphase publishes the exact Australian IQ8AC specification, warranty and local importer details.
SourcesSource 1Source 2Source 3Source 1Source 2Source 3Source 4

Outcome

IQ8HC
Available in Australia
IQ8AC
Available in Australia

Checked

IQ8HC
2026-08-06
IQ8AC
2026-08-02

Certifications

IQ8HC
AS/NZS 4777.2:2020 + A2, EN IEC 62109-1, EN IEC 62109-2 and RCM for IQ8HC-72-M-INT.
IQ8AC
The exact Australian datasheet publishes AS/NZS 4777.2:2020 + A2, EN IEC 62109-1/-2 and RCM compliance.

Warranty scope

IQ8HC
Australia and New Zealand; the current terms provide 25 years for eligible IQ8HC-72-M-INT units, subject to activation and claim conditions.
IQ8AC
Australia and New Zealand; Enphase publishes a 25-year limited warranty for eligible IQ8-series microinverters when the stated IQ Gateway and activation conditions are met.

Warranty remedy

IQ8HC
Repair, replacement or depreciated refund at Enphase's option.
IQ8AC
Repair, replacement or depreciated refund at Enphase's option.

Labour and reinstallation

IQ8HC
Uninstall and reinstallation labour are excluded from the product warranty. Removal and reinstallation are excluded; a separate installer program is conditional and shorter.
IQ8AC
Uninstall and reinstallation labour are excluded from the product warranty. Removal and reinstallation are excluded; a separate installer program is conditional and shorter.

Freight

IQ8HC
Eligible RMA and replacement freight is covered.
IQ8AC
Eligible RMA and replacement freight is covered.

Transfer and registration

IQ8HC
Transfers at the original site after the ownership form, fee and notice are completed within 30 days. Ownership change must be notified within 30 days; gateway activation conditions apply.
IQ8AC
Transfers at the original site after the ownership form, fee and notice are completed within 30 days. Ownership change must be notified within 30 days; gateway activation conditions apply.

Grid compatibility

IQ8HC
IQ8HC-72-M-INT is the 230 V, 50 Hz Australian SKU and publishes AS/NZS 4777.2:2020 + A2 compliance with IQ Relay.
IQ8AC
230 V IQ8AC-72-M-INT with AS/NZS 4777.2 compliance through the required IQ Relay.

Local product pathway

IQ8HC
No separate local pathway recorded
IQ8AC
No separate local pathway recorded

Buyer evidence

IQ8HC
Ready (88% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed.
IQ8AC
Ready (100% direct coverage): Local availability, buyer evidence, and the publication threshold are confirmed.

Safety notice

IQ8HC
No model-specific notice recorded
IQ8AC
No model-specific notice recorded

Review note

IQ8HC
Enphase publishes the exact Australian store SKU, datasheet, certification records and locally scoped warranty documentation.
IQ8AC
Enphase publishes the exact Australian IQ8AC specification, warranty and local importer details.

Sources

Australia purchase checks

Make the shortlist quote-ready

These checks sit beside the benchmark score. They are site, tariff and contract questions that no product score can settle.

  1. Lock the exact model and installation-date listing.

    Ask for every model number to appear on the quote and order. The Clean Energy Council product lists are live: STC creation requires listed products at installation, and network requirements may also depend on current approval.

  2. Obtain the site-specific connection settings.

    Have the retailer state the supply phase, inverter connection limit, export limit and any export-control cost. The local network connection agreement, not a generic datasheet, determines those settings. See the Australian Government's connection guidance.

  3. Test savings against the household, not a brochure.

    Ask which bills or interval data, tariff, feed-in rate, export limit and future loads support the savings and payback claim. Self-consumed electricity and tariff timing usually matter more than a headline feed-in rate. See the system sizing and battery savings guidance.

  4. Specify the operating outcome.

    Confirm the proposed inverter phase, PV input design, battery pairing and export-control configuration against the final connection agreement. A suitable product can still require a different site design or control setting.

  5. Name the party responsible after installation.

    Keep the retailer, installer, manufacturer warranty and escalation path in the contract. Australian Consumer Law guarantees apply separately from any manufacturer warranty; where one business supplied both product and installation, it is generally responsible for the remedy. See the ACCC guidance.

Decision snapshot

Where the comparison separates

OverallIQ8HC leads the global score by 3 points.
Strongest dimensionsIQ8HC: Safety & Compliance · IQ8AC: Safety & Compliance
Largest differenceIQ8HC has the largest pillar edge in Guarantee & Backbone (26 points).
Market evidenceIQ8HC: buyer ready · IQ8AC: buyer ready

A score lead is only meaningful inside this shared class or tier. Weigh it against the specification and evidence rows above before deciding.

Both products are scored in the Microinverter class, on the same rubric weighting. Scores are not comparable across classes or tiers. Full methodology.