back to inverters

Inverter

IQ8HC 208/240 V

0.384 kW · Microinverter · Single-phase · 208/240 V

EnphaseReleased 2024

62/ 100

Good

Global

Fanless Design25-Year WarrantyMicroinverter

The verdict. In our Inverter class, Enphase IQ8HC 208/240 V leads on safety & compliance.

59thof 63 in InverterBottom quarterclass average 70.5
Compare this inverter →Ask Watt →

The assessment

How it scores, by category

Efficiency66
Design & Flexibility50
Thermal & Physical Resilience68
Features & Integration62
Safety & Compliance78
Guarantee & Backbone60
Energy Ecosystem48

Market position

59thof 63 in InverterBottom quarter
566282

Our reading

IQ8HC 208/240 V scores 62, placing 59 of 63 in the Inverter class against a class average of 70.5. Its strongest scoring dimension is safety & compliance (78). Energy Ecosystem (48) is the dimension with the most room to move. Key specifications: 97.3% peak efficiency, 1 MPPT inputs, 25-year warranty.

The data

Power
0.384kW
Type
Micro
Peak eff
97.3%
MPPTs
1
Technology architecture

Microinverter

Architecture guide

Converts DC to AC at each solar module rather than at one central string inverter.

Product role
Storage, when used, sits elsewhere in the energy platform.
Published range
0.384 kW
Phase
Single phase
Backup boundary
Not recorded
Architecture describes the product boundary. It is not a system design or an equipment-pairing decision.

Warranty coverage: 25-year term

Coverage includes

✓Parts
–Labour
–Extendable
Market typical25yr0yr5yr10yr15yr20yr25yr

Parts only · term longer than 90 of 95 scored inverters

No inverter in the fleet publishes a year-by-year performance or output guarantee the way panels and batteries do - this shows the covered term against the market-typical term and where every scored inverter’s term lands (grey dots, sized by model count), plus what the warranty actually includes.

Before you buy
Local positionUse a market view to check local availability, approvals and warranty scope.
Ask the installerWill the exact IQ8HC 208/240 V model satisfy the site phase, array, MPPT, export-control and local grid requirements?

Verification & sources

Market context

Global evidencechange in the site menu

Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.

Benchmark anchor. The score remains anchored to the exact United States suffix at240 V. Current sheet certifies384 VA continuous output as well as384 VA peak; production labels may show380/384 VA. The208 V column remains distinct at360 VA continuous. Scored model: IQ8HC-72-M-US · checked 2026-10-05. Evidence.

Sources & references · checked 2026-09-01

Strong evidence coverage

19 of 19 scored criteria link directly to a published source.

Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.

How far the evidence reaches

1 of 3 questions with rows in the rings reach beyond manufacturer claim; none is measured by review.solar.123456
  1. OutputManufacturer claim4 rows in the rings
  2. EnduranceDesign facts from the maker's own material2 design facts beside the rings
  3. SafetyCertified or regulator-listed1 of 2 rows in the rings beyond claim
  4. BackingWarranty terms: the maker's commitment2 warranty terms beside the rings
  5. FitManufacturer claim3 rows in the rings6 design facts beside the rings
  6. FootprintNot assessed for inverters

Rings, outside in: manufacturer claim, certified or regulator-listed, third-party source. The centre is review.solar's own measurement, empty for every product today. Warranty terms and design facts that rest on the maker's own word are counted beside the rings; a reviewed absence, or one that reaches beyond the maker's claim, stays in them. How the evidence puzzle works

Record correction. North America IQ8HC datasheet DSH-00047-10.0-EN-2026-07-30. Exact US performance revision integrated 2026-10-05; dated market, warranty and regulator determinations are retained without a broad re-verification.

Help strengthen this record

These are published evidence gaps, not private submissions. A source is reviewed under the same methodology whether it comes from a reader, installer or manufacturer.

View the open evidence register
Change ledger

Product record history

1 change to this record · 22 products changed in this update
  1. Record updated

    VPP & grid services readiness: Evidence sources

    Before
    https://enphase.com/download/iq8hc-microinverter-data-sheet
    After
    https://developer-v4.enphase.com/vpp-plans; https://enphase.com/download/iq8hc-microinverter-data-sheet; https://enphase.com/installers/grid-services; https://enphase.com/installers/grid-services/dsgs-reward-program
    VPP & grid services readinessVPP & grid services readiness+2 in JSON record
4 changes to this record · 10 products changed in this update
  1. Record updated

    US Certifications

    Before
    CA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB), UL 62109-1 and NEC 2014-2023 rapid-shutdown compliance.
    After
    CA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB), UL 62109-1 and NEC 2014-2023 rapid-shutdown compliance.; Listed on the California Energy Commission Grid Support Solar Inverter List as IQ8HC-72-M-US {240V} and {208V}, with a UL 1741 Supplement SB certificate date of 13 May 2026 (list data unchanged since 1 October 2026). A listing records submitted certification data and does not show current sale.
    Grid & safety certificationUS market evidence+4 in JSON record
  2. Record updated

    Grid & safety certification: Evidence sources

    Before
    https://enphase.com/download/iq8hc-microinverter-data-sheet
    After
    https://enphase.com/download/iq8hc-microinverter-data-sheet; https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=InvertersList
    Grid & safety certificationGrid & safety certification
  3. Record updated

    US Warranty conditions

    Current text
    labour: Troubleshooting, uninstall and reinstall labour are excluded.; registration: Clause 2 conditions cover on registration within 45 days of first installation, with an exception for residents of California, Connecticut or any other state or province that forbids a returned registration card as a condition of cover. The attached registration form separately states that failure to complete and return it does not diminish warranty rights, and the document does not reconcile the two statements. The 25-year period runs from the Activation Date, the earlier of registration or Installer Portal activation (Covered Products Schedule). Claims go through the RMA process within the warranty period and within 90 days of discovering the defect (clause 5a); clause 4 asks that the product stay connected to the internet except for interruptions outside the owner's reasonable control, and states no numerical offline threshold.; remedy: Clause 6 lets Enphase choose between repair or replacement and a refund of the purchase price less reasonable depreciation. Enphase issues a refund only if it cannot provide a replacement and repair is not commercially practicable or cannot be timely made, or if the owner is willing to accept one. A repaired or replacement product carries the remainder of the original period or 90 days from receipt, whichever is later, and refunds or credits are paid within two weeks of Enphase receiving the product.; removal reinstallation: Removal and reinstallation are excluded.; transferability: Clause 3 extends cover to a later owner only if the product stays at the original location, the transferee submits the Change of Ownership Form, pays the transfer fee within 30 days of the transfer and meets the registration requirement in clause 2. The fee is set in the form and Enphase may adjust it.; transport: Accepted claims use Enphase's prepaid return and replacement-shipping process.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Grid & safety certificationUS market evidence+4 in JSON record
  4. Record updated

    US Evidence sources

    Before
    https://enphase.com/cybersecurity; https://enphase.com/download/2025-30-nov-enphase-energy-limited-warranty-microinverter; https://enphase.com/download/iq-system-controller-3-data-sheet; https://enphase.com/download/iq8hc-microinverter-data-sheet
    After
    https://enphase.com/cybersecurity; https://enphase.com/download/2025-30-nov-enphase-energy-limited-warranty-microinverter; https://enphase.com/download/iq-system-controller-3-data-sheet; https://enphase.com/download/iq8hc-microinverter-data-sheet; https://enphase.com/store/microinverters/iq8-series/iq8hc-microinverter; https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=InvertersList
    Grid & safety certificationUS market evidence+4 in JSON record
2 changes to this record · 1 product changed in this update
  1. Record updated

    Note

    Before
    The score is anchored to the exact United States suffix. The separate 380 VA continuous output remains visible as a supporting metric.
    After
    The score remains anchored to the exact United States suffix at240 V. Current sheet certifies384 VA continuous output as well as384 VA peak; production labels may show380/384 VA. The208 V column remains distinct at360 VA continuous.
    Number of MPPTs
  2. Record updated

    Source revision

    Current text
    North America IQ8HC datasheet DSH-00047-10.0-EN-2026-07-30. Exact US performance revision integrated 2026-10-05; dated market, warranty and regulator determinations are retained without a broad re-verification.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Number of MPPTs
5 changes to this record · 152 products changed in this update
  1. Evidence added

    DE Certifications

    Before
    Not previously recorded
    After
    DE market evidenceDE market evidence
  2. Evidence added

    DE Evidence sources

    Before
    Not previously recorded
    After
    https://enphase.com/de-de/store/microinverters; https://enphase.com/de-de/store/microinverters/iq8-series/iq8hc-microinverter
    DE market evidenceDE market evidence
  3. Evidence added

    DE Support Note

    Before
    Not previously recorded
    After
    The German Enphase microinverter store names IQ8HC-72-M-INT, not IQ8HC-72-M-US. The INT identity is a different record and is not transferred.
    DE market evidenceDE market evidence
  4. Evidence added

    DE Status

    Before
    Not previously recorded
    After
    unavailable
    DE market evidenceDE market evidence
  5. Record updated

    Source revision

    Before
    North America IQ8HC datasheet DSH-00047-7.0; regional identity separated 2026-08-06
    After
    North America IQ8HC datasheet DSH-00047-7.0; regional identity separated 2026-08-06. First-market DE overlay review 2026-09-01: official German catalogues recorded; existing Australian and United States overlays and scores unchanged.
    Number of MPPTs
4 changes to this record · 73 products changed in this update
  1. Evidence added

    Confidence

    Before
    Not previously recorded
    After
    high
    Number of MPPTs
  2. Evidence added

    State

    Before
    Not previously recorded
    After
    supported
    Number of MPPTs
  3. Evidence added

    Evidence sources

    Before
    Not previously recorded
    After
    https://enphase.com/download/iq8hc-microinverter-data-sheet
    Number of MPPTs
  4. Evidence added

    Value

    Before
    Not previously recorded
    After
    Module-level microinverter. The recorded one MPPT and input current are per microinverter, not array-wide system counts.
    Number of MPPTs

This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.

Evidence timeline

Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.

  1. US market evidence checked
  2. AU market evidence checked
  3. Series benchmark evidence checked
  4. Core scorecard evidence checked
  5. DE market evidence checked

Evidence record (JSON)

Scored by Solar Analytica Research

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.