back to panels

Emerging Technology

Centaur 2LT

510–540 W · Perovskite-silicon tandem

Oxford PVReleased ~2024

54/ 100

Average / Industry average

Global

25.0% EfficiencyClass-Leading Temp CoeffGlass-Glass

The verdict. In our Emerging Technology class, Oxford PV Centaur 2LT leads on architecture & design.

1stof 3 in Emerging TechnologyTop 10%class average 47.6
Compare this panel →Ask Watt →

The assessment

How it scores, by category

Architecture & Design81
Efficiency & Yield64
Durability (verified)43
Performance & Degradation40
Guarantee & Backbone40
Sustainability52

Market position

1stof 3 in Emerging TechnologyTop 10%
445454

Our reading

Centaur 2LT sits at the top of the Emerging Technology class with 54 points against a class average of 47.6. Its strongest scoring dimension is architecture & design (81), running 13.4 points above the class average on this dimension. Guarantee & Backbone (40) is the dimension with the most room to move. Underlying specifications include a module efficiency of 25.0%, Perovskite-silicon tandem cell technology, 10-year product warranty backed by a 10-year performance term.

The data

Power
540W
Efficiency
25.0%
Cell
Perovskite-silicon tande
Temp coeff
-0.21%/°C
Technology architecture

Perovskite-silicon tandem module

Architecture guide

Produces DC electricity at the roof. It contains no system-level power conversion or storage.

Product role
None in the module.
Published range
510–540 W
Electrical layer
DC module output
Construction
Not recorded
Architecture describes the product boundary. It is not a system design or an equipment-pairing decision.
Before you buy
Local positionUse a market view to check local availability, approvals and warranty scope.
Ask the installerWill the quote name the exact Centaur 2LT model and wattage, and who covers labour if the module warranty is used?

Verification & sources

Market context

Global evidencechange in the site menu

Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.

Benchmark anchor. The score is anchored to the highest published rating in this exact published series. Scored model: Centaur 2LT 540 · checked 2026-08-22. Evidence.

Sources & references · checked 2026-09-20

Strong evidence coverage

16 of 16 scored criteria link directly to a published source.

Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.

Record revision. Oxford PV Centaur 2LT June 2026 datasheet and current Gen2 product page, rechecked 2026-09-20. Encapsulation joined from 2 mm front glass, 2 mm rear glass, and an anodised aluminium frame.

Change ledger

Product record history

2 earlier entries recorded source rechecks rather than changes to the published figures, and are not listed here. Every entry remains in the evidence record.

6 changes to this record · 2 products changed in this update
  1. Record updated

    Architecture & Design pillar score

    Before
    64.5
    After
    81.1
    Primary datasheet
  2. Evidence added

    Encapsulation & frame construction: Evidence sources

    Before
    Not previously recorded
    After
    https://cdn.prod.website-files.com/6889d6b022777c95d667f7cb/6a38ea2ff1ababa5ac199a43_OxfordPV_Centaur_2LT_DataSheet_web.pdf
    Primary datasheet
  3. Evidence added

    Encapsulation & frame construction

    Before
    Not previously recorded
    After
    Glass-glass (framed)
    Primary datasheet
  4. Record updated

    Global score

    Before
    50.8
    After
    53.9
    Primary datasheet
  5. Record updated

    Source revision

    Before
    Oxford PV Centaur 2LT June 2026 datasheet and current Gen2 product page, rechecked 2026-08-22
    After
    Oxford PV Centaur 2LT June 2026 datasheet and current Gen2 product page, rechecked 2026-09-20. Encapsulation joined from 2 mm front glass, 2 mm rear glass, and an anodised aluminium frame.
    Primary datasheet
  6. Evidence added

    Encapsulation & frame construction: Evidence status

    Before
    Not previously recorded
    After
    sourced
    Primary datasheet
2 changes to this record · 109 products changed in this update
  1. Record updated

    Global score

    Before
    52
    After
    50.8
    Primary datasheet
  2. Record updated

    Efficiency & Yield pillar score

    Before
    70.4
    After
    64.3
    Primary datasheet
5 changes to this record · 118 products changed in this update
  1. Evidence added

    Independent energy yield: Evidence status

    Before
    Not previously recorded
    After
    reviewed_absence
    Independent energy yieldIndependent energy yield+2 in JSON record
  2. Record updated

    Global score

    Before
    54.1
    After
    52
    Primary datasheet
  3. Record updated

    Efficiency & Yield pillar score

    Before
    80.9
    After
    70.4
    Primary datasheet
  4. Evidence added

    Independent energy yield: Evidence sources

    Before
    Not previously recorded
    After
    https://scorecard.pvel.com/methodology/; https://scorecard.pvel.com/top-performers/; https://scorecard.pvel.com/wp-content/uploads/2022-PVEL-PV-Module-Reliability-Scorecard-Summary.pdf; https://scorecard.pvel.com/wp-content/uploads/2024-PV-Module-Reliability-Scorecard.pdf
    Independent energy yieldIndependent energy yield+2 in JSON record
  5. Evidence added

    Independent energy yield

    Before
    Not previously recorded
    After
    No public independent yield result found in reviewed sources
    Independent energy yieldIndependent energy yield+2 in JSON record
3 changes to this record · 13 products changed in this update
  1. Record updated

    Source revision

    Before
    Oxford PV Centaur 2LT June 2026 datasheet and current Gen2 product page, rechecked 2026-08-01
    After
    Oxford PV Centaur 2LT June 2026 datasheet and current Gen2 product page, rechecked 2026-08-22
    Primary datasheet
  2. Record updated

    AU Support Note

    Before
    Centaur 2LT is a published saleable Gen2 product, but exact Australian availability, certification and local warranty support remain unproven.
    After
    Centaur 2LT remains a published Gen2 product. Oxford PV expects volume-manufactured tandem modules in 2027 and reports customer pilots, but exact Australian availability, certification and local warranty support remain unproven.
    Performance guarantee period (yrs)Primary datasheet+1 in JSON record
  3. Record updated

    Hail resistance: Evidence sources

    Before
    After
    https://cdn.prod.website-files.com/6889d6b022777c95d667f7cb/6a38ea2ff1ababa5ac199a43_OxfordPV_Centaur_2LT_DataSheet_web.pdf
    Primary datasheet
1 change to this record · 106 products changed in this update
  1. Record updated

    Durability (verified) pillar score

    Before
    42.5
    After
    42.6
    Primary datasheet

This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.

Evidence timeline

Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.

  1. Core scorecard evidence checked
  2. AU market evidence checked
  3. Series benchmark evidence checked
  4. Plain-language warranty summary checked

Evidence record (JSON)

Scored by Solar Analytica Research

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.