back to batteries

Performance & Value

Reserva

6.31–15.79 kWh · LFP · DC-coupled

FroniusReleased 2025

67/ 100

Very good

Global

LFP100% Usable5 kWh Modular

The verdict. In our Performance & Value class, Fronius Reserva leads on capacity & usability. Home-battery reliability is rarely independently verified, so judge on chemistry, safety certification and the backing company.

15thof 41 in Performance & ValueTop halfclass average 64.7
Compare this batteryAsk Watt →

The assessment

How it scores, by category

Capacity & Usability91
Power & Efficiency86
Longevity (verified)60
Safety & Chemistry71
Guarantee & Backbone58
Energy Ecosystem44

Market position

15thof 41 in Performance & ValueTop half
536775

Our reading

Reserva scores 67, placing 15 of 41 in the Performance & Value class against a class average of 64.7. Its strongest scoring dimension is capacity & usability (91), running 5.5 points above the class average on this dimension. Energy Ecosystem scores 44, the lowest pillar for this product. The class average on energy ecosystem is 49. Key specifications: LFP, 95% round-trip efficiency, 6.55 kW continuous output.

The data

Chemistry
LFP
Power
6.55kW
Round-trip
95%
Cycle life
Not recorded

Capacity guarantee: minimum retained at year 10

6.3 kWhfull4.4at yr 10
60708090100Rated capacity 100%Guaranteed floor 70.0%70.0%0yr2yr4yr6yr8yr10yr
Rated capacity (reference)Guaranteed floor: 70.0% at yr 10

No year-by-year capacity schedule is published for this product - the manufacturer guarantees only this end-of-term minimum, not a specific decline curve. Capacity figure based on the sourced usable capacity of the base configuration; modular systems scale with additional modules.

Blackout protection

68 / 100#20 of 50 batteries
fleet low 46median 68fleet high 100
No backupGrid-forming

Whole-home (via hybrid inverter)

Continuous power
6.55kW

The blackout score is a standalone benchmark of outage resilience only - it re-weights sourced specs already scored in this product’s pillars (backup tier, switchover, surge strength, backup power, off-grid recharge) and never affects the overall score. Dots show the full battery fleet; the marker is this product.

System decision

Australian system fit

Only exact, manufacturer-named Australian paths are shown. A shared brand, product family or output rating is not proof of compatibility.

Inverter pairing

Fronius Primo GEN24 Plus

Confirmed pairing

The exact named inverter pairing is recorded as confirmed for Australia.

Single phase · AU · checked 2026-08-02

Backup: Full Backup requires a Fronius grid-disconnection device in addition to the battery and inverter.

Required hardware: Fronius Backup Controller or other Fronius-approved grid-disconnection device for Full Backup.

Configuration boundary: Two to five Reserva modules per tower; final power and parallel limits are inverter-dependent.

Source 1Source 2

Confirmed pairing

The exact named inverter pairing is recorded as confirmed for Australia.

Three phase · AU · checked 2026-08-02

Backup: Full Backup requires a Fronius grid-disconnection device in addition to the battery and inverter.

Required hardware: Fronius Backup Controller or other Fronius-approved grid-disconnection device for Full Backup.

Configuration boundary: Full Backup availability and output vary by exact Symo model; use the current Fronius battery overview and inverter manual.

Source 1Source 2

A documented relation does not establish site sizing, network approval, protected-load design, firmware state or installer acceptance. When no exact relation is recorded, compatibility remains unestablished in this catalogue.

Before you buy

Two things to check

Local positionUse a market view to check local availability, approvals and warranty scope.

Ask the installer: What usable capacity, backup power and warranted operating conditions will the installed Reserva configuration deliver?

Verification & sources

Market context

Global evidencechange in the site menu

Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.

Benchmark anchor. Capacity range describes supported configurations; the score remains anchored to the named reviewed reference configuration, not the largest stack. Scored model: Reserva 6.3 (6.31 kWh usable) · checked 2026-07-31. Evidence.

Australia buyer evidence

Australian warranty decision

1 product record

Read the Australian warranty as a claim pathway: the headline term is separate from remedy, labour, freight, site work, transfer and registration conditions.

  1. Fronius Reserva 6.31 kWh · Home battery

    Australian evidence checked 2026-08-02.

    Covered3 sources

    Australian warranty scope: Australia is Warranty Country Group 3; Fronius Warranty Plus provides a 10-year term, 70% retained capacity, labour for removal/replacement and normal national shipping.

    Structured claim terms: Recorded.

    Term
    10 yr productStated in the structured comparison
    Product remedy
    CoveredRepair or replacement under Fronius Warranty Plus.
    Labour
    CoveredApproved removal and replacement labour is covered.
    Freight
    CoveredNormal domestic shipping is covered.
    Removal and reinstallation
    Not coveredApproved removal and replacement are covered; additional travel is excluded.
    Transferability
    CoveredThe remaining warranty automatically transfers with the covered product.
    Registration and conditions
    Not statedWarranty Plus registration and the country-group conditions apply.
    Exact AU source coverage
    CoveredSource 1Source 2Source 3These are the URLs stored on the AU market evidence overlay. A linked source does not make a field marked Not stated covered.

Sources & references · checked 2026-08-02

Strong evidence coverage

14 of 14 scored criteria link directly to a published source.

Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.

Evidence timeline

Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.

  1. Core scorecard evidence checked
  2. AU market evidence checked
  3. Plain-language warranty summary checked
  4. Series benchmark source checked

Scored by Solar Analytica Research

Further reading from Signals

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.