back to panels

Premium Performance

Hi-MO X10 Scientist LR7-72HVH

640–660 W · 72-cell · HPBC · Rear contact · Mono-glass

LONGiReleased ~2025

67/ 100

Very good

Global

Back-Contact Cell24.43% EfficiencyClass-Leading Temp Coeff15+ Yrs Field-Proven

The verdict. In our Premium Performance class, LONGi Hi-MO X10 Scientist LR7-72HVH leads on architecture & design.

37thof 47 in Premium PerformanceBottom quarterclass average 69.1
Compare this panelAsk Watt →

The assessment

How it scores, by category

Architecture & Design84
Efficiency & Yield66
Durability (verified)47
Performance & Degradation78
Guarantee & Backbone68
Sustainability58

Market position

37thof 47 in Premium PerformanceBottom quarter
606780

Our reading

Hi-MO X10 Scientist LR7-72HVH scores 67, placing 40 of 47 in the Premium Performance class against a class average of 69.1. Its strongest scoring dimension is architecture & design (84). Durability (verified) scores 47, the lowest pillar for this product. The class average on durability (verified) is 57. Underlying specifications include a module efficiency of 24.43%, HPBC cell technology, 15-year product warranty backed by a 30-year performance term.

The data

Power
660W
Efficiency
24.43%
Cell
HPBC
Temp coeff
-0.26%/°C
Technology architecture

HPBC module

Architecture guide

Produces DC electricity at the roof. It contains no system-level power conversion or storage.

Product role
None in the module.
Published range
640–660 W
Electrical layer
DC module output
Construction
Rear contact, Mono-glass
Architecture describes the product boundary. It is not a system design or an equipment-pairing decision.

Performance guarantee: 30-year linear output

660 Wrated586W at yr 30
80859095100Guaranteed floor 88.8%Product 15yr88.8%0yr5yr10yr15yr20yr25yr30yr
Projected outputGuaranteed floor: 88.8% at yr 30Product warranty ends yr 15

Wattage figure based on the sourced rated power (660 W) applied to the guaranteed floor; modular/format differences aside, this is the same rated-power spec shown above.

Modelled effective output, year by year

592W542W

Year 1 to year 25, at 30°C and 1000 W/m². Rated 660 W at STC.

How this is modelled

Compounds this panel’s own published first-year (1%) and annual (0.35%/yr) degradation figures against its 660 W rated (STC) output, then derates for the ambient and irradiance selected. Output is scaled roughly linearly with irradiance (1000W/m² against the 1000 W/m² STC reference). This is the dominant real-world effect at low light, whether from cloud, shading or soiling. Output is then further derated for heat, from this panel’s own NOCT (45°C) and temperature coefficient (-0.26%/°C), giving an estimated cell temperature of 61°C at that ambient and irradiance. A datasheet-derived estimate, not a field measurement or a warranty guarantee: it does not account for this panel’s own low-light efficiency response (a separate, less-consistently-published spec), or for wind and system design. See NOCT and temperature coefficient in the glossary.

Control panel

30°C
1000 W/m²
Year1510152025
Watts592 W583 W573 W563 W552 W542 W
% of rated89.7%88.4%86.8%85.2%83.6%82.1%
Before you buy
Local positionUse a market view to check local availability, approvals and warranty scope.
Ask the installerWill the quote name the exact Hi-MO X10 Scientist LR7-72HVH model and wattage, and who covers labour if the module warranty is used?

Verification & sources

Market context

Global evidencechange in the site menu

Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.

Benchmark anchor. The score is anchored to the highest published rating in this exact series. Scored model: LR7-72HVH-660M · checked 2026-08-18. Evidence.

Sources & references · checked 2026-08-18

Strong evidence coverage

25 of 27 scored criteria link directly to a published source.

Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.

Record revision. Re-sourced 2026-08-18. The record previously cited a Draft BGV02 revision dated 18 November 2024 covering a 630-650 W band, and carried the series name Hi-MO X10 Explorer. LONGi has retired that classification: the Hi-MO X10 range is now published as Scientist and Guardian, and the current sheet for this model is BGV03 20260509, read page-by-page because LONGi serves it as an image-only scan with no text layer. The manufacturer band moves to 640-670 W; the retained Australian range is 640-660 W because the CER export checked 2026-08-12 lists this model only across that band. The scored bin therefore moves to 660 W and the module efficiency to 24.43%.

Change ledger

Product record history

9 changes to this record · 106 products changed in this update
  1. Record updated

    Global score

    Before
    67.7
    After
    67.2
    Primary datasheet
  2. Evidence removed

    Damp heat extended (2000h): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    No longer recorded
    Fire classification (IEC 61730)
  3. Evidence removed

    Awards: Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf; https://www.pv-magazine.com/2025/12/08/pv-magazine-awards-2025-winners-revealed/
    After
    No longer recorded
    AwardsFire classification (IEC 61730)
  4. Evidence removed

    Damp heat extended (2000h)

    Before
    1000h IEC 61215 standard
    After
    No longer recorded
    Fire classification (IEC 61730)
  5. Record updated

    Durability (verified) pillar score

    Before
    48.2
    After
    47.3
    Primary datasheet
  6. Record updated

    Architecture & Design pillar score

    Before
    85.1
    After
    83.7
    Primary datasheet
  7. Evidence removed

    Damp heat extended (2000h): Evidence status

    Before
    sourced
    After
    No longer recorded
    Fire classification (IEC 61730)
  8. Evidence removed

    Awards

    Before
    Major International Award specific to product
    After
    No longer recorded
    AwardsFire classification (IEC 61730)
  9. Evidence removed

    Awards: Evidence status

    Before
    sourced
    After
    No longer recorded
    AwardsFire classification (IEC 61730)
34 changes to this record · 2 products changed in this update
  1. Record updated

    Policy

    Before
    highest_in_series
    After
    highest_in_market
    Primary datasheetFire classification (IEC 61730)
  2. Record updated

    Scored Model

    Before
    LR7-72HVH-650M
    After
    LR7-72HVH-660M
    Primary datasheetFire classification (IEC 61730)
  3. Record updated

    Module efficiency (%)

    Before
    24.1
    After
    24.43
    Primary datasheetFire classification (IEC 61730)
  4. Record updated

    Scored Label

    Before
    650 W
    After
    660 W
    Primary datasheetFire classification (IEC 61730)
  5. Record updated
  6. Record updated

    Fire classification (IEC 61730): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf; https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  7. Record updated

    Positive loading (MQT16, Pa): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf; https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  8. Record updated

    Negative loading (MQT16, Pa): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf; https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  9. Record updated
  10. Record updated

    Temp coefficient Pmax (%/C): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  11. Record updated

    Annual degradation (%/yr): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  12. Record updated

    First-year degradation (%): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  13. Record updated
  14. Record updated

    Guarantee period (yrs): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  15. Record updated

    AU Certifications

    Before
    After
    The CER approved PV module export checked 2026-08-12 lists exact LR7-72HVH models across 640-660 W. The retained range is the intersection of that listing with the current manufacturer sheet, which spans 640-670 W.
    AU market evidencePrimary datasheet+3 in JSON record
  16. Record updated

    Performance guarantee period (yrs): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  17. Record updated

    Contact: Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  18. Record updated

    Source revision

    Before
    Exact family documentation reviewed 2026-08-06
    After
    Re-sourced 2026-08-18. The record previously cited a Draft BGV02 revision dated 18 November 2024 covering a 630-650 W band, and carried the series name Hi-MO X10 Explorer. LONGi has retired that classification: the Hi-MO X10 range is now published as Scientist and Guardian, and the current sheet for this model is BGV03 20260509, read page-by-page because LONGi serves it as an image-only scan with no text layer. The manufacturer band moves to 640-670 W; the retained Australian range is 640-660 W because the CER export checked 2026-08-12 lists this model only across that band. The scored bin therefore moves to 660 W and the module efficiency to 24.43%.
    Primary datasheetFire classification (IEC 61730)
  19. Record updated

    Source

    Current text
    checked: 2026-08-18; source revision: LONGi Hi-MO X10 Scientist LR7-72HVH datasheet BGV03 20260509, AU Hi-MO X10 limited warranty, and CER export checked 2026-08-12; source url: https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheetFire classification (IEC 61730)
  20. Evidence added

    Market

    Before
    Not previously recorded
    After
    AU
    Primary datasheetFire classification (IEC 61730)
  21. Record updated

    Range Label

    Before
    630–650 W
    After
    640–660 W
    Primary datasheetFire classification (IEC 61730)
  22. Record updated

    Power tolerance (%): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  23. Record updated

    NOCT (C): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf; https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  24. Record updated

    Module efficiency (%): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  25. Record updated

    Guaranteed end-of-warranty output (%): Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  26. Record updated

    Cell technology tier: Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
  27. Record updated

    Warranty transferability: Evidence sources

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf; https://static.longi.com/Limited_Warranty_for_LON_Gi_PV_Modules_HE_Single_Glass_Series_EN_20220325_AU_9d217fb193.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf; https://static.longi.com/Limited_Warranty_for_LON_Gi_PV_Modules_HE_Single_Glass_Series_EN_20220325_AU_9d217fb193.pdf
    Warranty transferabilityPrimary datasheet+1 in JSON record
  28. Record updated

    Power tolerance (%)

    Before
    3
    After
    3.0
    Primary datasheetFire classification (IEC 61730)
  29. Record updated

    Canonical identity

    Before
    LONGi Hi-MO X10 Explorer 72HVH 650 W
    After
    LONGi Hi-MO X10 Scientist LR7-72HVH 660 W
    Primary datasheetFire classification (IEC 61730)
  30. Record updated

    Ranges

    Current text
    checked: 2026-08-18; market: AU; max: 660; min: 640; range label: 640–660 W; source revision: LONGi Hi-MO X10 Scientist LR7-72HVH datasheet BGV03 20260509, AU Hi-MO X10 limited warranty, and CER export checked 2026-08-12; source url: https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf; unit: W

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheetFire classification (IEC 61730)
  31. Record updated

    AU Evidence sources

    Before
    https://www.longi.com/au/products/modules-series/hi-mo-x10/; https://www.longi.com/au/products/modules/hi-mo-x10-scientist/
    After
    https://cer.gov.au/document/cec-approved-pv-modules-0; https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf; https://static.longi.com/Limited_Warranty_for_LON_Gi_Hi_MOX_10_Solar_Modules_Distributed_Generation_AU_1_c8a7831c18.pdf; https://www.longi.com/au/products/modules-series/hi-mo-x10/; https://www.longi.com/au/products/modules/hi-mo-x10-scientist/
    AU market evidencePrimary datasheet+3 in JSON record
  32. Record updated

    Model

    Before
    LR7-72HVH-650M
    After
    LR7-72HVH-640M through LR7-72HVH-660M (144 half-cells, 6 x 24, HPBC 2.0 back-contact, single glass); scored model LR7-72HVH-660M
    Primary datasheetFire classification (IEC 61730)
  33. Record updated

    Published name

    Before
    Hi-MO X10 Explorer 72HVH
    After
    Hi-MO X10 Scientist LR7-72HVH
    Primary datasheetFire classification (IEC 61730)
  34. Record updated

    Primary Source

    Before
    https://static.longi.com/LR_7_72_HVH_630_650_M_30_30_and_15_Explorer_BGV_02_20241118_EN_Draft_426c93d9d1.pdf
    After
    https://static.longi.com/LR_7_72_HVH_640_670_M_30_30_and_15_Frame_Scientist_BGV_03_20260509_EN_3b5e2a1a91.pdf
    Primary datasheetFire classification (IEC 61730)
1 change to this record · 7 products changed in this update
  1. Record updated

    Class

    Before
    Global Tier-1
    After
    Premium Performance
    Fire classification (IEC 61730)

This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.

Evidence timeline

Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.

  1. Core scorecard evidence checked
  2. AU market evidence checked
  3. Series benchmark evidence checked
  4. Plain-language warranty summary checked

Evidence record (JSON)

Scored by Solar Analytica Research

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.