The assessment
How it scores, by category
Market position
The data
Solar-only string inverter
Converts PV string DC into grid-connected AC.
- Product role
- No native battery conversion path is recorded for the product.
- Published range
- 3–6 kW
- Phase
- Single phase
- Backup boundary
- No native backup recorded
What the documents establish
Published evidence, source-reviewed non-disclosure and unresolved questions remain separate from the product score.
Warranty coverage: 10-year term
Coverage includes
Parts & labour · term longer than 24 of 95 scored inverters
No inverter in the fleet publishes a year-by-year performance or output guarantee the way panels and batteries do - this shows the covered term against the market-typical term and where every scored inverter’s term lands (grey dots, sized by model count), plus what the warranty actually includes.
Verification & sources
Market context
Global evidencechange in the site menu
Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.
Benchmark anchor. Renewed rows through 2029 govern current status; older duplicate rows expired in January 2026. Scored model: ASW6000-S-G2 · checked 2026-08-27. Evidence.
Sources & references · checked 2026-09-22
Strong evidence coverage
24 of 24 scored criteria link directly to a published source.
Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.
Record revision. Exact family technical sources, Australian warranty and current regulator snapshot checked 2026-08-27. First-market US and DE overlay review 2026-09-01: official regional catalogues recorded; Australian overlays and scores unchanged. Exact Australian source reconciliation 5 October 2026: the current ASW6000-S-G2 datasheet states 97.8% maximum efficiency and 97.5% European efficiency; older global 98.2% maximum is replaced for this AU assessment. Type II surge protection is documented, but its AC/DC side is not identified. The unsupported DC-only scored input is withdrawn; generic Type II protection is not treated as absent, and the exact surge-side evidence gap remains open. Overvoltage categories DC II/AC III are distinct from surge-device types. Benchmark, market and warranty evidence dates are unchanged.
- Sourced valuesData card →
- Warranty summary10-year product warranty →
Show 3 more
- Rated AC power (kW)Manufacturer ↗
- Monitoring & smart featuresManufacturer ↗
- Firmware & security disclosureManufacturer ↗
Help strengthen this record
These are published evidence gaps, not private submissions. A source is reviewed under the same methodology whether it comes from a reader, installer or manufacturer.
- Semiconductor technologyNot stated in reviewed documentsThe public documents reviewed for this record do not state this value. A published or independent source is requested.Offer a source
- Open protocol & API maturityNot stated in reviewed documentsThe public documents reviewed for this record do not state this value. A published or independent source is requested.Offer a source
- VPP & grid services readinessNot stated in reviewed documentsThe public documents reviewed for this record do not state this value. A published or independent source is requested.Offer a source
- EV charging integrationNot stated in reviewed documentsThe public documents reviewed for this record do not state this value. A published or independent source is requested.Offer a source
Product record history
9 changes to this record · 1 product changed in this update
Source revision
- Current text
- Exact family technical sources, Australian warranty and current regulator snapshot checked 2026-08-27. First-market US and DE overlay review 2026-09-01: official regional catalogues recorded; Australian overlays and scores unchanged. Exact Australian source reconciliation 5 October 2026: the current ASW6000-S-G2 datasheet states 97.8% maximum efficiency and 97.5% European efficiency; older global 98.2% maximum is replaced for this AU assessment. Type II surge protection is documented, but its AC/DC side is not identified. The unsupported DC-only scored input is withdrawn; generic Type II protection is not treated as absent, and the exact surge-side evidence gap remains open. Overvoltage categories DC II/AC III are distinct from surge-device types. Benchmark, market and warranty evidence dates are unchanged.
The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.
Primary datasheetSurge protection: Evidence sources
- Before
- https://solplanet.net/wp-content/uploads/2022/10/Datasheet-ASW-3K-6K-S-G2-Series-0722_AU_V02.pdf
- After
- No longer recorded
Peak efficiency (%): Evidence sources
- Before
- https://solplanet.net/wp-content/uploads/2022/10/Datasheet-ASW-3K-6K-S-G2-Series-0722_AU_V02.pdf
- After
- https://solplanet.net/wp-content/uploads/2020/11/Global-Brochure-EU-EN_0524_V5_web.pdf; https://solplanet.net/wp-content/uploads/2022/10/Datasheet-ASW-3K-6K-S-G2-Series-0722_AU_V02.pdf
1 change to this record · 32 products changed in this update
DE Warranty confirmation
- Before
- Not previously recorded
- After
- unconfirmed
2 changes to this record · 49 products changed in this update
US Support Note
- Current text
- The Solplanet /us/products/asw-3-6k-s-g2-series path returns 404. A /us/ hostname path that opens a news article is not a United States product catalogue. ASW H-S2 is a different family and is not this S-G2 record. Re-audited 2026-09-22: this determination rests solely on the fetch failure recorded above, with no independently reachable regional catalogue, store or archived copy consulted. Downgraded to not_reviewed - unavailable was not confirmed, and this pass did not re-fetch to confirm available either.
The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.
US market evidenceUS market evidence+1 in JSON record
11 changes to this record · 12 products changed in this update
DE Warranty scope
- Before
- Not previously recorded
- After
- Germany; no German inverter warranty naming ASW6000-S-G2 was attached, so six-field terms are not transferred from the Australian AISWEI instrument.
DE Status
- Before
- Not previously recorded
- After
- available
DE Evidence sources
- Before
- Not previously recorded
- After
- https://solplanet.net/au/products/asw-3-6k-s-g2-series; https://solplanet.net/de/products/asw-3-6k-s-g2-series; https://solplanet.net/wp-content/uploads/2022/09/Datenblatt-ASW-3K-6K-S-G2-Series-Global-DE_0824_web.pdf5_.pdf
US Evidence sources
- Before
- Not previously recorded
- After
- https://solplanet.net/au/products/asw-3-6k-s-g2-series; https://solplanet.net/de/products/asw-3-6k-s-g2-series; https://solplanet.net/us/products/asw-3-6k-s-g2-series
Source revision
- Before
- Exact family technical sources, Australian warranty and current regulator snapshot checked 2026-08-27
- After
- Exact family technical sources, Australian warranty and current regulator snapshot checked 2026-08-27. First-market US and DE overlay review 2026-09-01: official regional catalogues recorded; Australian overlays and scores unchanged.
DE Support Note
- Before
- Not previously recorded
- After
- solplanet.net/de lists the ASW S-G2 series including ASW6000-S-G2. This is not the H-S2 hybrid record. Manufacturer listing is established; distributor inventory is not inferred.
DE Certifications
- Before
- Not previously recorded
- After
- The German ASW 3-6K S G2 product page names ASW3000-S-G2 through ASW6000-S-G2, including scored ASW6000-S-G2, and publishes a German S-G2 series datasheet.
US Status
- Before
- Not previously recorded
- After
- unavailable
US Certifications
- Before
- Not previously recorded
- After
DE Grid and installation context
- Before
- Not previously recorded
- After
- Single-phase German string family named on the German product page. The reviewed German page and German series datasheet do not print VDE-AR-N 4105. Connection approval remains installation-specific. ASW H-S2 is a different family.
US Support Note
- Before
- Not previously recorded
- After
- The Solplanet /us/products/asw-3-6k-s-g2-series path returns 404. A /us/ hostname path that opens a news article is not a United States product catalogue. ASW H-S2 is a different family and is not this S-G2 record.
1 change to this record · 6 products changed in this update
Product record
kind: inverter; brand: Solplanet; name: ASW S-G2; model: Current Australian family ASW3000-S-G2, ASW3680-S-G2, ASW4000-S-G2, ASW5000-S-G2 and ASW6000-S-G2; scored model ASW6000-S-G2; score: 70.6
Primary datasheet
This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.
Evidence timeline
Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.
- Core scorecard evidence checked
- US market evidence checked
- DE market evidence checked
- AU market evidence checked
- Series benchmark evidence checked
- Plain-language warranty summary checked
Scored by Solar Analytica Research
Further reading from Findings
Stay across the benchmark.
New scorecards, score changes and market signals, published as they happen.
Our reading
ASW S-G2 scores 70, placing 41 of 63 in the Inverter class against a class average of 70.5. Its strongest scoring dimension is safety & compliance (87), running 8.4 points above the class average on this dimension. Energy Ecosystem scores 40, the lowest pillar for this product. The class average on energy ecosystem is 48. Key specifications: 97.8% peak efficiency, 2 MPPT inputs, 10-year warranty.