← All Findings
Australian inverters · Living benchmark

45 Australian inverter records clear the buyer-ready gate. 2 do not.

An inverter can be globally scored and still be unready for an Australian purchasing decision. The local layer requires exact-model availability, certification, warranty scope, grid compatibility, no active model-specific safety notice, and at least 50% criterion-level source linkage. This report rebuilds from those gates whenever the catalogue changes.

Readiness is earned across every local evidence gate AU PURCHASE-PRIORITY INVERTER RECORDSReadiness is earned across every local evidence gate 45 Buyer-ready 2 In review
Buyer-ready status is independent of score and rank. It requires an available Australian overlay, all category-specific local evidence, no active exact-model safety notice, and at least 50% criterion-level source coverage. Generated 2026-07-26.
Chart data
SeriesValueNote
Buyer-ready45
In review2
Publication gate

Six questions stand between a global score and an Australian buying record

  1. 01
    Exact model

    Available in Australia. A similar overseas SKU cannot stand in for the benchmarked model.

  2. 02
    Certification

    Local evidence present. The record names the relevant product and standards evidence.

  3. 03
    Warranty

    Local scope present. The term must apply to the Australian model without an unresolved confirmation caveat.

  4. 04
    Grid

    Compatibility stated. Voltage, grid standard or paired-system dependency must be clear enough for buyer screening.

  5. 05
    Safety

    No active exact-model notice. An active regulator notice keeps the product in review regardless of its score.

  6. 06
    Sources

    At least 50% linked. Criterion-level source linkage prevents a complete-looking regional shell over a thin global record.

These are publication-readiness checks, not recommendation criteria. None of them changes a product score.
The queue separates strong linkage from a complete local buying record CRITERION SOURCE COVERAGEThe queue separates strong linkage from a complete local buying record 47 80 to 100% linked 0 50 to 79% linked 0 Below 50% linked
Direct source coverage is calculated from active scored criteria for the 47 current Australian purchase-priority inverter records. Crossing 50% is necessary but does not replace certification, warranty, grid, safety or exact-model checks.
Chart data
SeriesValueNote
80 to 100% linked47
50 to 79% linked0
Below 50% linked0

45 of 47 priority inverter records currently clear every Australian evidence gate. The other 2 stay visible because a missing local fact is not a negative product judgement.

review.solar living dataset

The current Australian queue

  1. Enphase IQ9N-A Microinverter Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current CER snapshot lists IQ9N-A-INT, approved 17 March 2026 and expiring 17 March 2029.
    Warranty
    Australian/New Zealand LGL-00031 v4.0 explicitly names IQ9N-A-INT for 25 years from Activation Date: the earlier of registration or activation at the original location through the Installer Portal, with activation linked to permission to operate. This instrument applies to activation on or after 30 September 2025 unless a newer warranty governs that activation date. Purchase must be from Enphase or an authorised reseller. Enphase Energy, Inc. is the warrantor; the Australian service entity is separate. Australian Consumer Law guarantees remain additional.
    Grid compatibility
    The exact model or family appears in the current Australian approved-inverter export. DNSP settings, export limits and site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  2. Fronius Verto Plus Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The CER approved inverter list, export last modified 24 September 2026 and re-read on 6 October 2026, lists all six exact Verto Plus models (15.0, 17.5, 20.0, 25.0, 30.0 and 33.3 Plus) through 19 June 2029.; The exact Australian datasheet names IEC 62109-1/-2 and applicable national grid standards.
    Warranty
    Fronius International Limited Warranty EN_0326 applies to Fronius inverters purchased on or after 1 June 2026. Section 12.2.1 gives Australia a five-year Warranty Plus period without additional requirements, and Sections 12.2.3 and 12.2.4 give a total of ten years after eligible Solar.web registration within 30 months of ex-works delivery. Section 2.2 separately states that the inverter warranty applies only if the inverter is registered on Solar.web within 30 months of ex-works delivery; the instrument does not resolve this conflict. The instrument does not name Verto Plus models.
    Grid compatibility
    Three-phase Australian identity. CER product listing does not establish DNSP, site, export-limit, installation or commissioning approval.
    Safety and source
    No model-specific notice recorded
    regional source
  3. GoodWe DNS G4 Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    TUV Rheinland Australia certificate of suitability AZ 69028757, published by GoodWe Australia, lists GW3K-DNS-G40, GW3.6K-DNS-G40, GW4.2K-DNS-G40, GW5K-DNS-G40 and GW6K-DNS-G40 against AS/NZS 4777.2:2020 + Amd 1:2021 + Amd 2:2024, IEC 62109-1:2010 and IEC 62109-2:2011, issued 27 October 2025 and expiring 27 October 2030. The Clean Energy Regulator approved inverter list shows the same five DNS G4 codes, including GW6K-DNS-G40 (AS4777-2 2020), approved on 27 April 2026 with expiry on 27 April 2029 (list file dated 24 September 2026).
    Warranty
    GoodWe Technologies Co., Ltd. Rev 5.9, dated 17 September 2026, names DNS G4 for five years of AU/NZ limited cover. The period starts at first installation or 12 months after production, whichever is earlier. The ten-year all-on-grid promotion requires manufacture after 1 July 2020 and installation, registration and SEMS connection after 1 January 2021. The separate five-year spare-parts extension names DNS and DNS G3, not DNS G4. Authorised supply and the supplied unit's governing terms remain controlling.
    Grid compatibility
    Single-phase 230 V Australian string-inverter family with AS/NZS 4777.2 compliance.
    Safety and source
    No model-specific notice recorded
    regional source
  4. GoodWe ESA G20 Power Module Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current Australian regulator snapshot lists GW3K, GW3.6K, GW5K, GW6K, GW8K and GW9.999K EHA-G20 under the ESA family through 25 July 2028.; GW10K-EHA-G20 appears on the broader manufacturer sheet but is not included in this Australian record because it is absent from the current local approval snapshot.
    Warranty
    Australia and New Zealand; the governing ESA warranty explicitly names GW3K-EHA-G20, GW3.6K-EHA-G20, GW5K-EHA-G20, GW6K-EHA-G20, GW8K-EHA-G20 and GW9.999K-EHA-G20 for ten years.
    Grid compatibility
    Single-phase hybrid power-module family with current AS/NZS 4777.2 regulator entries. DNSP settings, export limits and final site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  5. Hoymiles HIT L G3 Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current Clean Energy Regulator CSV lists HIT-12L-G3-AU, HIT-15L-G3-AU and HIT-20L-G3-AU as three separate AS4777-2 2020 rows in series HIT-(5-20)L-G3-AU.; All three exact rows carry approval date 30 July 2026 and current expiry 30 July 2029. Approval status is temporal and must be rechecked before purchase or installation.
    Warranty
    Australia; the current governing Residential Storage Inverter warranty expressly names all three accepted HIT L G3 AU models for 10 years, subject to its installation, channel, claim and exchange conditions.
    Grid compatibility
    Three-phase 400 V hybrid inverter family. Exact AS4777-2 2020 regulator listing is established for the three accepted model strings only. DNSP connection, export limits, protected-load design and commissioning settings remain site-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  6. Solplanet ASW H-S2 Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current regulator snapshot lists all five exact 3 kW to 6 kW H-S2 models through 22 January 2029.; Single-phase hybrid family with exact current AS/NZS 4777.2 regulator entries and IEC 62109 safety evidence.
    Warranty
    Australia; the current AISWEI warranty explicitly names ASW H-S2 for 120 months, with separately governed extensions available up to a total 20 years.
    Grid compatibility
    Single-phase hybrid family with exact current AS/NZS 4777.2 regulator entries and IEC 62109 safety evidence. DNSP settings, export limits and final site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  7. Sungrow SH10RS Single-Phase Hybrid Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The exact Australian SH8.0/10RS datasheet lists IEC 62109-1, IEC 62109-2, IEC 62477-1, IEC 62920 and AS/NZS 4777.2:2020 grid compliance for SH10RS.; Sungrow's user manual (SH8.0-10RS-UEN-Ver16-202512, section 6.10.2.1 Meter Connection) states that the inverter's export control function, which requires an external smart meter, has not been tested to AS/NZS 4777.2:2020.
    Warranty
    Australia; Sungrow's 10-Year Standard Warranty Terms and Conditions (footer V4.31_202510, file name V4.32) list SH8.0RS and SH10RS among the Category 1 inverters manufactured and installed from 1 April 2020 and originally sold in Australia, covered for ten years from installation and no more than eleven years from the manufacturing date, whichever comes first (page 1).
    Grid compatibility
    AU product page identifies the SH8.0/10RS as a 1-phase hybrid inverter with 240 V rated AC voltage. The Version 6 datasheet prints a rated AC voltage of 230 V, and the Version 3 datasheet printed 220 V, 230 V and 240 V.
    Safety and source
    No model-specific notice recorded
    regional source
  8. Sungrow SG RS Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The exact Australian datasheet publishes IEC 62109 and AS/NZS 4777.2 compliance.
    Warranty
    Australia; Sungrow's current warranty page lists the SG5.0RS-ADA, SG8.0RS, SG9.0RS and SG10RS under its 10-year standard inverter warranty for units originally sold in Australia and manufactured and installed from 1 April 2020. The term runs ten years from installation but no more than eleven years from the manufacturing date, whichever comes first, in Australia only.
    Grid compatibility
    Single-phase 230/240 V Australian string-inverter family with AS/NZS 4777.2 compliance.
    Safety and source
    No model-specific notice recorded
    regional source
  9. Sungrow SH5T / SH10T Three-Phase Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The Australian approved-inverter list (regulator export dated 24 September 2026) names SH5T and SH10T in its Residential series with the (AS4777-2 2020) suffix, approved 14 August 2024 and expiring 14 August 2027. Certificate SGS/230890 was recorded from the list on 2 August 2026; the export carries no certificate column, so the identifier was not re-read on 7 October 2026.; The exact datasheet lists AS/NZS 4777.2:2020, IEC/EN 62109, EN 50549-1, VDE-AR-N 4105 and further national grid standards.
    Warranty
    Sungrow Australia's current 10-year standard warranty terms (published file V4.32, footer V4.31_202510, October 2025) explicitly name SH5T and SH10T for a 10-year term from installation, capped at 11 years from manufacture. The standard remedy includes repair or replacement, standard freight up to a stated cap and a published service rebate rather than an unlimited promise to meet every site cost.
    Grid compatibility
    Three-phase 220/380 V, 230/400 V or 240/415 V hybrid family with exact Australian approved-list entries. DNSP settings, export limits and phase-balance requirements remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  10. Sungrow SH5.0/6.0RS Priority 1

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The Australian CEC approved-inverter export (data as at 30 September 2026) lists exact SH5.0RS and SH6.0RS Residential Hybrid models to AS/NZS 4777.2:2020 through 30 January 2028.; The exact Australian datasheet lists IEC/EN 62109-1, IEC/EN 62109-2 and AS/NZS 4777.2:2020.
    Warranty
    Australia; Sungrow's 10-Year Standard Warranty terms explicitly list SH5.0RS and SH6.0RS for units originally sold in Australia, with cover for 10 years from installation and no more than 11 years from manufacture. Version 4.2 (PDF created 2 April 2024) and the later PDF linked from Sungrow Australia's warranty page (created 7 October 2025, footer V4.31_202510, file named V4.32) both list SH5.0RS and SH6.0RS with the same period. The live warranty page also lists SH5.0RS and SH6.0RS, with SBR160 and above, under a Category 3 for models with off-grid application, with a note that the model must have Internet and be connected to iSolarCloud; the page's warranty clause sets terms for Category 1 and Category 2 only and is silent on which terms apply to Category 3.
    Grid compatibility
    Single-phase 230 V hybrid family with exact-model Australian CEC listings. DNSP settings, export limits and battery compatibility remain installation-specific. Sungrow's current user manual (SH3.0-6.0RS&SH5.0-6.0RS-20-UEN-Ver22-202603, PDF page 86) states that the export control function, which needs an external smart meter, has not been tested to AS/NZS 4777.2:2020.
    Safety and source
    No model-specific notice recorded
    regional source
  11. AlphaESS SMILE-M-S Inverter Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current CER snapshot lists M8, M9 and M10, approved 7 July 2026 and expiring 7 July 2029.
    Warranty
    Australia; the exact SMILE-M-S inverter warranty provides ten years for the named M8, M9 and M10 family.
    Grid compatibility
    The exact model or family appears in the current Australian approved-inverter export. DNSP settings, export limits and site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  12. FoxESS H3-Pro Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The CER approved inverter list, last modified 2 October 2026 and read on 7 October 2026, lists exact H3-Pro-15.0 (AS4777-2 2020) at 15 kW, approved 21 January 2026 and expiring 21 January 2029.; The current Australian datasheet and manual identify H3-Pro-15.0 as a three-phase storage inverter.
    Warranty
    The Australian and New Zealand warranty policy, Version 4.0 dated 1 April 2026, expressly names H3-Pro-15.0. The standard term is 120 months from installation, capped at 132 months after manufacture. Conditional service-rebate and transport provisions do not establish unrestricted labour or freight cover.
    Grid compatibility
    Three-phase Australian identity. CER product listing does not establish DNSP, site, export-limit, installation or commissioning approval.
    Safety and source
    No model-specific notice recorded
    regional source
  13. Fronius Symo GEN24 Plus SC Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The Clean Energy Regulator export of the approved-inverter list dated 24 September 2026 names Symo GEN24 6.0, 8.0, 10.0 and 12.0 Plus SC (AS4777-2 2020), each approved 6 March 2025 and expiring 6 March 2028. TÜV Rheinland Australia certificate of suitability AZ 69028071, held by Fronius Australia Pty Ltd, names the same models for IEC 62109-1, IEC 62109-2 and AS/NZS 4777.2:2020+A1 from 23 October 2024 to 23 October 2029; the register export does not print a certificate number.; Fronius publishes exact-family conformity material for AS/NZS 4777.2 and IEC 62109, and the Australian datasheet lists further national grid standards.
    Warranty
    Fronius International Limited Warranty Conditions EN_0326 (country group 2, Australia and New Zealand) apply to products purchased on or after 1 June 2026 (clause 2.1) and cover Fronius inverters placed on the market in the country without naming individual models (clause 2.2). Clause 2.2 states that inverter cover applies only if the inverter is registered on Solar.web within 30 months of initial delivery ex works, while clause 12.2.1, under a heading stating independence from registration, gives inverters a 5-year term even without additional requirements being met. Registration on Solar.web within 30 months of delivery ex works gives a warranty period of 10 years in total (clauses 12.2.3 and 12.2.4). The Warranty Plus model applies during the warranty period (clause 12.2.2) and covers the spare part or equivalent replacement, the removal and replacement labour carried out by Fronius or a specialist installer commissioned by Fronius, and standard national shipping (clause 6.3.1). Clause 12.2.4 also names a promotional 5-year Warranty Plus extension, for a total of 10 years of Warranty Plus, for inverters installed between 1 October 2025 and 31 December 2026. In Australia the warranty is given by Fronius Australia Pty Ltd (clause 12.4.1).
    Grid compatibility
    Three-phase 380/220 V or 400/230 V hybrid family with exact Australian approved-list entries. DNSP settings, export limits and backup switching approval remain site-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  14. Sigenergy SigenStor 10 kW Single-Phase Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    AS/NZS 4777.2:2020; IEC 62109.1; IEC 62109.2
    Warranty
    Australia and New Zealand factory limited warranty, revision dated 26 May 2026: 10 years for the Sigen Energy Controller. The exact SigenStor EC 10.0 SP AU is named in the model list as the energy controller of the SigenStor-10S systems. Precondition (v) requires the device to remain connected to the internet for firmware updates; if it is disconnected for over one year, coverage adjusts to 5 years from the original activation date.
    Grid compatibility
    The Clean Energy Council lists the exact SigenStor EC 10.0 SP AU (AS4777-2 2020) as an approved single-phase PV-and-battery inverter, with a listed expiry date of 4 March 2028 when checked.
    Safety and source
    No model-specific notice recorded
    regional source
  15. Sigenergy SigenStor EC TP Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    IEC 62109.1; IEC 62109.2; AS/NZS 4777.2:2020
    Warranty
    Australia and New Zealand; each of the three Australian warranty revisions read on 7 October 2026 gives the Sigen Energy Controller component ten years. The Factory Limited Warranty for Sigenergy Product (header date 12/6/2024) lists the 12.0 TP AU in its model list, printed as 'SigeStor 12.0 TP AU', among other typographical inconsistencies. The later Factory Limited Warranty for SigenStor revisions (header dates 10/6/2025 and 26 May 2026, the current one) do not name the 12.0 TP AU. Their three-phase Energy Controller entries are SigenStor EC 5.0, 10.0, 15.0, 20.0, 25.0 and 30.0 TP AU, and the current revision also lists an EC 8.0 TP AU against the single-phase 8S system code. The Factory Limited Warranty for Inverter System (header date 24 July 2026), read on 9 October 2026, gives ten years for Sigen Hybrid 5.0, 10.0, 15.0, 20.0, 25.0 and 30.0 TP AU. Its covered-product table does not name 12.0 TP AU under the TP AU entry, and it names Sigen Hybrid models rather than SigenStor EC 12.0 TP AU, so it is not treated as a warranty for this model.
    Grid compatibility
    The CEC lists the exact SigenStor EC 12.0 TP AU as a three-phase PV-and-battery grid-connect inverter under certificate EESS-240671-0, with a listed expiry of 7 April 2028 when checked.
    Safety and source
    No model-specific notice recorded
    regional source
  16. Solis S6-GR1P Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current CER inverter export checked 4 October 2026 lists exact S6-GR1P3K-S, S6-GR1P3.6K-S, S6-GR1P4K-S, S6-GR1P4.6K-S, S6-GR1P5K-S and S6-GR1P6K-S with the AS4777-2 2020 suffix under Ginlong Technologies Co Ltd, approved 1 September 2023 and expiring 15 November 2026. This replaces the older 16 October observation; renewal beyond 15 November remains unverified.; The exact Australian datasheet publishes AS/NZS 4777.2:2020 and IEC 62109-1/-2 compliance.
    Warranty
    Five-year standard limited warranty plus a further five years for eligible units purchased from 1 January 2024 when registered and kept connected to SolisCloud, subject to the published terms. Section A of the terms makes the Solis Limited Warranty conditional on SolisCloud registration, maintained connection, and installation and maintenance by SAA, SEANZ or New Zealand equivalent accredited technicians.
    Grid compatibility
    Single-phase Australian grid-tied family with AS/NZS 4777.2:2020 compliance.
    Safety and source
    No model-specific notice recorded
    regional source
  17. Solplanet ASW S-G2 Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current regulator snapshot contains renewed rows for all five exact models through 22 January 2029; older duplicate rows expired 21 January 2026 and do not govern current status.; Single-phase string family with exact current AS/NZS 4777.2 regulator entries, IEC 62109 and multiple published national grid codes.
    Warranty
    Australia; the current AISWEI warranty explicitly names ASW S-G2 for 120 months, with separately governed extensions available up to a total 20 years.
    Grid compatibility
    Single-phase string family with exact current AS/NZS 4777.2 regulator entries, IEC 62109 and multiple published national grid codes. DNSP settings, export limits and final site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  18. Sungrow SG RT Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The exact series datasheet publishes IEC 62109 and AS/NZS 4777.2 compliance.; The Clean Energy Regulator approved-inverter export of 24 September 2026 has series RT rows for SG5.0RT, SG7.0RT, SG8.0RT, SG10RT, SG15RT and SG20RT and no SG12RT row; a CER listing for the scored SG12RT bin is not publicly established. The datasheet linked from Sungrow's Australian SG5.0/8.0/10RT product page (page 2, Version 16) covers SG5.0RT, SG7.0RT, SG8.0RT and SG10RT only.
    Warranty
    Australia; Sungrow's current warranty page and its linked terms (file name V4.32_202510; document footer V4.31_202510) list SG5.0RT through SG12RT under the 10-year standard inverter warranty, which runs ten years from installation and no more than eleven years from manufacture, whichever comes first.
    Grid compatibility
    Three-phase 230/400 V string-inverter family with Australian grid-code compliance.
    Safety and source
    No model-specific notice recorded
    regional source
  19. Sungrow SH15T / SH20T / SH25T Three-Phase Priority 2

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current Australian regulator snapshot lists SH15T, SH20T and SH25T as three-phase multiple-mode PV and battery inverters through 18 April 2027.; The exact sheet lists IEC/EN 62109 and AS/NZS 4777.2:2020 together with further national grid standards.
    Warranty
    Sungrow Australia's Version 4.2 standard warranty names SH15T, SH20T and SH25T in Category 1 for ten years from installation, but no more than eleven years from manufacture, for inverters manufactured and installed from 1 April 2020 (page 1).
    Grid compatibility
    Three-phase 220/380 V, 230/400 V or 240/415 V hybrid family with exact current Australian listings. DNSP settings and export limits remain installation-specific. The manual states that the export control functionality has not been tested to AS/NZS 4777.2:2020 (PDF page 84).
    Safety and source
    No model-specific notice recorded
    regional source
  20. Deye SUN SG05 AU-AM2-P Priority 3

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The CER export last modified 10 August 2026 lists exact 7, 7.6, 8 and 10 kW AU-AM2-P codes through 20 July 2029.; The exact Australian datasheet names AS/NZS 4777.2 and IEC/EN 62109-1/-2.
    Warranty
    Current AU library V2.17, reviewed 4 October 2026, explicitly names the 7/7.6/8/10 kW SG05LP1-AU-AM2-P pattern for ten years. It states effect from 1 November 2023 and serial 2311XXXXXX and later. Term starts at original purchase from Deye, capped at ten years and six months from factory delivery, subject to a sales-order period/formal contract. Actual unit serial and applicable contract must be checked. Years six to ten exclude LCD, fan, repair labour, taxes/duties and installer costs; CT/meter two years and data logger five years are separate accessory terms.
    Grid compatibility
    Single-phase Australian identity. CER product listing does not establish DNSP, site, export-limit, installation or commissioning approval.
    Safety and source
    No model-specific notice recorded
    regional source
  21. FoxESS H1 G2 Priority 3

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current regulator snapshot lists the exact 3.0, 3.7, 4.6, 5.0 and 6.0 kW H1-G2 models through 3 January 2027.; Single-phase hybrid family with exact current AS/NZS 4777.2 regulator entries, IEC 62109 and multiple published national grid codes.
    Warranty
    Australia; the current FoxESS inverter warranty explicitly names the five retained H1 G2 models for 120 months from installation, capped at 132 months from manufacture.
    Grid compatibility
    Single-phase hybrid family with exact current AS/NZS 4777.2 regulator entries, IEC 62109 and multiple published national grid codes. DNSP settings, export limits and final site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  22. Fronius Primo GEN24 Plus Single-Phase Priority 3

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The 29 August 2026 CER inverter export lists Primo GEN24 10.0 Plus at 9.999 kW through 14 August 2029. The previous recorded expiry was 17 August 2026. Primo GEN24 8.0 Plus renewed on the same date.; The current CER export, last modified 2 October 2026 and read 6 October, lists exact Primo GEN24 3.0, 3.6, 4.0, 4.6, 5.0 and 6.0 Plus through 3 January 2027, extending the previously recorded 5 October 2026 expiry. Their approval dates and ratings are unchanged. The separate 8.0 and scored 10.0 Plus entries remain current through 14 August 2029.; Fronius publishes exact Primo GEN24 8.0-10.0 conformity material for AS/NZS 4777.2 and IEC 62109.
    Warranty
    Fronius Australia provides eligible registered inverters with 10 years of Fronius Warranty Plus covering materials, servicing and transport, with paid extension options to 15 years. Registration and local conditions apply.
    Grid compatibility
    Single-phase 220/230 V family with exact Australian conformity material. Final DNSP export limits, meter configuration, backup switching equipment and battery pairing remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  23. GoodWe DNS G3 Priority 3

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    All five DNS G3 codes, GW3000-DNS-30 to GW6000-DNS-30, are on the Clean Energy Council approved inverter list published by the Clean Energy Regulator, listed as AS4777-2 2020, approved 1 September 2022 and current to 27 July 2027 in the export of 24 September 2026. GoodWe Australia's download centre publishes TUV Rheinland IEC/EN 62109-1:2010 and 62109-2:2011 certificate 50535048 and a companion certificate, AN 50608302 0001, that lists the five codes. The datasheet itself refers readers to the GoodWe website for certificates.
    Warranty
    GoodWe Technologies Co., Ltd. Rev 5.9, dated 17 September 2026, names DNS G3 for five years of AU/NZ limited cover. The period starts at first installation or 12 months after production, whichever is earlier. A separate paragraph names DNS and DNS G3 for a further five years of spare-parts cover, in which GoodWe bears only the hardware cost of the spare inverter; shipping, labour and on-site costs are excluded. The ten-year all-on-grid promotion requires manufacture after 1 July 2020 and installation, registration and SEMS connection after 1 January 2021; the terms are silent on how the promotion and the spare-parts extension combine. Authorised supply and the supplied unit's governing terms remain controlling.
    Grid compatibility
    Single-phase 230 V Australian string-inverter family with AS/NZS 4777.2 compliance.
    Safety and source
    No model-specific notice recorded
    regional source
  24. Hoymiles HiOne S G3 Priority 3

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    Current CER system rows include 8S, 10S and 12S combinations, approved 13 August 2026 and expiring 31 December 2027.
    Warranty
    Australia; the current warranty names the 8S, 10S and 12S inverter layer for ten years.
    Grid compatibility
    The exact model or family appears in the current Australian approved-inverter export. DNSP settings, export limits and site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  25. SolaX X3-HYB G4 Pro Priority 3

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The Australian approved-inverter list (data as at 30 September 2026) names all seven X3-HYB-P models from 4 kW to 15 kW in the X3-HYB G4 PRO series under the AS4777-2 2020 designation, each approved 1 May 2026 and expiring 1 May 2029.; The exact Australian datasheet lists IEC 62109-1/-2, AS/NZS 4777, VDE-AR-N 4105, G98/G99, EN 50549 and CEI 0-21.
    Warranty
    SolaX's Australian Version 1.6 warranty explicitly names X3-HYB-4.0/5.0/6.0/8.0/10.0/12.0/15.0-P for 10 years, subject to authorised supply, installation, activation and registration. The remedy is at SolaX's option and normal ground transport is capped at AUD 200 per case.
    Grid compatibility
    Three-phase 220/380 V or 230/400 V hybrid family with exact Australian approved-list entries. The approved list shows the 5, 10 and 15 kW models at 5, 10 and 15 kW. The Australian datasheets separately give AS 4777 output ratings of 4,999, 9,999 and 14,999 for those three models, with the unit printed as W or VA depending on the datasheet version and row. DNSP acceptance remains site-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  26. GoodWe GW9.99K-EHB-AU-G11 Priority 4

    In review100% sourced

    A current regulator safety notice applies to this exact model.

    Certification
    The current Australian approved-inverter export lists GW9.99K-EHB-AU-G11 to AS/NZS 4777.2:2020 through 23 March 2027.
    Warranty
    GoodWe publishes a 10-year EHB warranty. Its current Australian terms cover hardware, specified transport and conditional authorised on-site labour reimbursement.
    Grid compatibility
    The exact 230 V single-phase 9.99 kW model remains in the Australian approved-inverter export; final DNSP suitability remains installation-specific.
    Safety and source
    active
    regional source
  27. GoodWe ET G2 Three-Phase Hybrid Priority 4

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The Australian CEC approved-inverter export dated 24 September 2026 lists exact GW6000-ET-20, GW8000-ET-20, GW9900-ET-20, GW12K-ET-20 and GW15K-ET-20 models to AS/NZS 4777.2:2020 through 29 October 2027.; The exact system manual lists IEC 62109-1/-2, VDE-AR-N 4105 and EN 50549-1. A TÜV Rheinland Australia certificate of suitability published by GoodWe (AZ 69027616, issued under JAS-ANZ accreditation, 17 November 2023 to 17 November 2028) lists the same five models to IEC 62109-1:2010, IEC 62109-2:2011 and AS/NZS 4777.2:2020+A1.
    Warranty
    Australia and New Zealand; GoodWe's current Rev 5.9 limited warranty, dated 17 September 2026, explicitly places ET G2 under 10 years of cover for eligible products.
    Grid compatibility
    Three-phase 380/400 V hybrid family with exact-model CEC listings. DNSP acceptance, export settings, battery pairing and backup design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  28. GoodWe SDT G3 Priority 4

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    GoodWe Australia publishes TÜV Rheinland Australia Certificate of Suitability AZ 69028473, which names GW20K-SDT-AU30 at 20000 W and lists AS/NZS 4777.2:2020 Amd 2:2024, IEC 62109-1:2010 and IEC 62109-2:2011, with an expiry date printed as 07/04/2030. TÜV Rheinland certificate R 50653532 0001, valid from 15 November 2024, also names GW20K-SDT-AU30 under IEC 62109-1:2010 and IEC 62109-2:2011. The CER approved inverter list (file last modified 24 September 2026) carries GW20K-SDT-AU30 (AS4777-2 2020), approved 6 November 2025 and expiring 6 November 2028. The Australian datasheet V2.1 prints no standards row.
    Warranty
    GoodWe Technologies Co., Ltd. Rev 5.9, dated 17 September 2026, names SDT G3 for five years of AU/NZ limited cover. The period starts at first installation or 12 months after production, whichever is earlier. The ten-year all-on-grid promotion requires manufacture after 1 July 2020 and installation, registration and SEMS connection after 1 January 2021. The separate five-year spare-parts extension names DNS, DNS G3, MS and MS G3; it does not name SDT G3. Authorised supply and the supplied unit's governing agreement and version remain controlling; current terms do not establish the treatment of older purchases.
    Grid compatibility
    Three-phase 400 V Australian string-inverter family with AS/NZS 4777.2 compliance.
    Safety and source
    No model-specific notice recorded
    regional source
  29. Hoymiles HiOne T G3 Priority 4

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    Current CER system rows include 8T, 10T, 12T, 16T and 20T combinations, approved 13 August 2026 and expiring 31 December 2027.
    Warranty
    Australia; the current exact HiOne system warranty names the retained three-phase inverter layer for ten years.
    Grid compatibility
    The exact model or family appears in the current Australian approved-inverter export. DNSP settings, export limits and site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  30. iStore Hybrid 5000/6000 1PH Priority 4

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    IEC 62109-1/-2; AS/NZS 4777.2:2020
    Warranty
    iStore's March 2026 Australian terms name IS-HYB-5000-1PH and IS-HYB-6000-1PH (page 2) and provide a 120-month inverter warranty that runs from the earlier of 180 days after shipment from iStore or the installation date (section 2.1, page 3). Defective hardware is provided free of charge and iStore covers return postage of the defective unit; replacements must be exchanged by a CEC accredited installer who has completed iStore Solar Service training (pages 4 and 5). The installer replacement rebate is AUD 150 ex GST per incident, plus AUD 25 per additional unit at the same site, paid only to verified installers or retailers at iStore's discretion; the terms state that it is subject to change (pages 4 and 5).
    Grid compatibility
    Single-phase 220/230/240 V family with Australian A, B, C and New Zealand AS/NZS 4777 grid profiles documented in the supplied user manual. The manual states the inverters were not tested to AS/NZS 4777.2:2020 Section 5 (Appendix K) for multiple inverter combinations (page 58). DNSP acceptance and export settings remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  31. iStore Hybrid 5000/6000 3PH Priority 4

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The CER CEC approved inverters list, data as at 30 September 2026 (workbook modified 2 October 2026), lists exact IS-HYB-5000-3PH and IS-HYB-6000-3PH models to AS/NZS 4777.2:2020 with expiry 9 May 2027.; The exact datasheet lists IEC 62109-1/-2 and AS/NZS 4777.2:2020.
    Warranty
    Australia; iStore's March 2026 terms explicitly name IS-HYB-5000-3PH and IS-HYB-6000-3PH and provide a 120-month inverter warranty. Accepted-return freight is covered and any installer rebate remains discretionary.
    Grid compatibility
    Three-phase 230/400 V family with Australian Region A, B and C grid profiles documented and exact-model CEC listings. DNSP settings and export limits remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  32. Solis S6 Three-phase LV Hybrid Priority 4

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The CER export last modified 10 August 2026 lists all five exact AU family codes through 11 March 2029.; TÜV Rheinland Australia Certificate of Suitability AZ 69028709, issued 13 October 2025 and expiring 13 October 2030, names Ginlong Technologies Co., Ltd. as certificate holder and lists the five exact AU models S6-EH3P8K02-NV-YD-L-AU, S6-EH3P9.9K02-NV-YD-L-AU, S6-EH3P10K02-NV-YD-L-AU, S6-EH3P12K02-NV-YD-L-AU and S6-EH3P15K02-NV-YD-L-AU against AS/NZS 4777.2:2020 (with A1 and Amd 2:2024), IEC 62109-1:2010 and IEC 62109-2:2011. The Australian product page publishes the certificate.
    Warranty
    Ginlong terms Solis-20240802-GL give five standard years, and section A gives an extra five years for Solis string inverters under 110 kW capacity. The official 2024 Solis Australasia statement extends the additional five years to all Solis inverters up to 110 kW, which includes this 15 kW AU identity. Eligibility includes authorised Australian supply, purchase and manufacture from January 2024, accredited installation, SolisCloud registration and maintained connection. The limited-warranty period starts at the later of installation or purchase. Earlier products retain their applicable prior terms; paid extension options and their service scope are separate.
    Grid compatibility
    Three-phase Australian identity. CER product listing does not establish DNSP, site, export-limit, installation or commissioning approval.
    Safety and source
    No model-specific notice recorded
    regional source
  33. Enphase IQ8AC Priority 5

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The exact Australian datasheet publishes AS/NZS 4777.2:2020 + A2, EN IEC 62109-1/-2 and RCM compliance.; The current CER approved-inverter export checked 4 October 2026 lists exact IQ8AC-72-M-INT (AS4777-2 2020) under Enphase Energy Inc, approved 13 July 2023 and expiring 9 January 2027, at 0.36 kW AC. This extends the previously recorded 11 October 2026 expiry. Other regional suffixes are separate identities; approval does not establish installation-specific DNSP acceptance.
    Warranty
    Australia and New Zealand; Enphase publishes a 25-year limited warranty for eligible IQ8-series microinverters when the stated IQ Gateway and activation conditions are met.
    Grid compatibility
    230 V IQ8AC-72-M-INT with AS/NZS 4777.2 compliance through the required IQ Relay.
    Safety and source
    No model-specific notice recorded
    regional source
  34. SOFAR PowerAll ESI T1 Priority 5

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The CER export last modified 24 September 2026 lists all six exact ESI T1 codes through 28 May 2029.; Australian factory warranty Version 2.4 explicitly names ESI 5-12K-T1.
    Warranty
    SOFARSOLAR Australian factory warranty Version 2.4 explicitly covers ESI 5-12K-T1 for 120 months. Necessary product labour and one freight movement are included, while third-party site costs and broader transport remain excluded or discretionary.
    Grid compatibility
    Three-phase Australian identity. CER product listing does not establish DNSP, site, export-limit, installation or commissioning approval.
    Safety and source
    No model-specific notice recorded
    regional source
  35. SolarEdge Home Hub Single-Phase Priority 5

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The 24 September 2026 approved-inverter export lists SE10000H-MM (AS4777-2 2020) at 10 kW, approved 24 February 2022, through 17 May 2027, and the same row appears in the list dated 30 September 2026. The separate SE10000H (AS4777-2 2020) row runs through 17 January 2027. The Australian Home Hub datasheets name SE10000H-MM.
    Warranty
    SolarEdge's current Australian warranty provides a 12-year standard inverter term, subject to its conditions.
    Grid compatibility
    The exact 10 kW Australian Home Hub family is a 220/230 V single-phase inverter; final DNSP suitability remains installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  36. Fronius Primo GEN24 SC / Plus SC Priority 6

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The CER approved-inverter CSV lists all twelve exact SC and Plus SC model strings under Fronius Australia Pty Ltd, approved 30 July 2026 and expiring 30 July 2029.; Every reviewed CER model string carries the AS4777-2 2020 suffix.
    Warranty
    Fronius Australia states that eligible inverters commissioned on or after 1 June 2026 can receive ten years of Fronius Warranty Plus after Solar.web registration within the published registration window. The page states that Warranty Plus covers materials, servicing and transport; country conditions govern eligibility.
    Grid compatibility
    Single-phase 3.0, 3.68, 4.0, 4.6, 5.0 and 6.0 kW CER identities under AS/NZS 4777.2:2020. CER listing does not establish DNSP, site, export-limit, installation or commissioning approval.
    Safety and source
    No model-specific notice recorded
    regional source
  37. Growatt SPH6000TL-HU-AU Priority 6

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    Growatt's official AU SPH3000-6000TL-HU datasheet names the exact SPH6000TL-HU and lists CE, IEC 62109, IEC 61000, AS/NZS 4777.2:2020 and CEC
    Warranty
    Growatt's official AU datasheet names the exact SPH6000TL-HU and states a 10-year warranty. Growatt's AU warranty card includes the SPH3000-6000TL-HU family for export-market installations; the card is non-transferable and excludes labour costs.
    Grid compatibility
    The exact 6 kW single-phase hybrid model is documented for 230 V, 50/60 Hz operation and is marked AS/NZS 4777.2:2020 and CEC on Growatt's AU datasheet. DNSP acceptance remains installation-specific.
  38. Growatt MIN TL-XH2 Priority 6

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The Australian approved-inverter export lists all seven exact MIN TL-XH2 models from 2.5 kW to 6.0 kW under Shenzhen Growatt New Energy Co Ltd, with approval dated 10 July 2024 and expiry dated 10 July 2027.; Growatt publishes an exact-family AS/NZS 4777 certificate and the exact datasheet lists IEC 62109 and multiple national grid codes.
    Warranty
    The exact datasheet publishes a 10-year warranty. Growatt's Australian warranty card names MIN2500-6000TL-XH2, is non-transferable, leaves the remedy to Growatt, and limits logistics and labour responsibility after year five.
    Grid compatibility
    Single-phase 230 V Australian hybrid family with exact-model approved-inverter entries. DNSP settings, export limits and installation acceptance remain site-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  39. Solis S6 PLUS Single-Phase Hybrid Priority 6

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The current Australian approved-inverter export lists S6-EH1P6K-L-PLUS-AU through 2 August 2027; local documentation publishes AS/NZS 4777.2 and IEC/EN 62109-1/-2.
    Warranty
    Five-year standard limited warranty. Ginlong terms Solis-20240802-GL (section A) give an extra five years for Solis string inverters under 110 kW capacity, and the 2024 Solis Australasia statement extends the further five years to all Solis inverters up to 110 kW, which includes this 6 kW model. Eligibility includes authorised Australian supply, purchase on or after 1 January 2024, manufacture after that date, accredited installation, SolisCloud registration and a maintained SolisCloud connection. The limited-warranty period starts at the later of installation or purchase. Earlier products keep their prior terms; paid extension options and their service scope are separate.
    Grid compatibility
    The exact 230 V single-phase 6 kW model is current in the Australian approved-inverter export; final DNSP suitability remains installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  40. SAJ H2 S3 Priority 7

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The reviewed Australian approval state lists exact H2-5K-S3, H2-6K-S3, H2-7K-S3, H2-8K-S3, H2-10K-S3 and H2-10K-S3-A model rows to AS/NZS 4777.2:2020. All six were approved 24 August 2023 and currently expire 22 November 2026.; Approval Watch records an expiry-change event for each exact row in source version au-cec-inverter-2026-08-10-7ecc0443a0aa, retrieved 10 August 2026 and editorially approved 13 August 2026. The event changes approval validity only and does not change the product score.
    Warranty
    Australia; the live governing warranty covers H2 Series for ten years from commissioning or ten years and six months from shipment, whichever occurs first, subject to its terms.
    Grid compatibility
    Single-phase AS/NZS 4777.2:2020 approval is established for the six exact rows only. DNSP connection limits, export settings, backup circuit scope and site design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  41. SolaX X1-Hybrid G4 Priority 7

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    AS/NZS 4777; RCM remark: the user manual's type-label symbol legend (latest change-history entry version 05, 22 July 2023; PDF page 8) lists an RCM remark symbol. No EESS or other RCM registration record for this model was read.; The CER approved-inverter export last modified 24 September 2026 lists X1 Hybrid G4 models X1-Hybrid-3.0-D, 3.7-D, 5.0-D, 6.0-D and 7.5-D (AS4777-2 2020), approved 17 August 2022 and expiring 24 May 2027. The 5.0 kW entry is rated 4.999 kW AC and the scored 7.5-D entry 7.5 kW AC. Other suffixes are separate identities, and approval does not establish installation-specific DNSP acceptance.
    Warranty
    SolaX Power Network Technology (Zhejiang) Co., Ltd. provides Australian Version 1.6 cover, naming X1-Hybrid-3.0/3.7/5.0/6.0/7.5-D G4 for ten years. Standard cover ends at 120 months from installation or 129 months from manufacture, whichever comes first. The stated NSW PDRS exception requires an approved scheme installation and guarantees ten years from installation; it is not a general extension. Version 1.6 applies to units sold and installed from 1 February 2025 through authorised channels with certified installation, commissioning, registration and activation; earlier units retain their applicable previous terms.
    Grid compatibility
    Single-phase 220/230/240 V family. The Australian 5 kW variant is capped at 4,999 W under AS/NZS 4777; the 7.5 kW model is the scored highest series benchmark. DNSP acceptance remains installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  42. FoxESS KH Priority 8

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The Australian approved-inverter export (CER) lists KH7, KH8, KH9, KH9.9, KH10 and KH10.5, each to AS4777-2 2020, from 13 June 2025 to 13 June 2028.
    Warranty
    FoxESS Australia's inverter warranty policy names KH7, KH8, KH9, KH9.9, KH10 and KH10.5 and provides 120 months from installation, capped at 132 months from manufacture, whichever comes first (Version 4.0, 1 April 2026, clause iii). That is the version listed on FoxESS Australia's downloads page on 7 October 2026. Service and transport rebates are conditional (clause v). Version 3.4 (1 October 2024) also required annual inspection by an authorised technician from the sixth year; Version 4.0 states no annual-inspection condition. Neither document states which version applies to a given installation.
    Grid compatibility
    The exact KH10.5 is approved to AS/NZS 4777.2:2020. DNSP export and interoperability settings remain installation-specific; AusNet also lists the exact model in its interoperable inverter register.
    Safety and source
    No model-specific notice recorded
    regional source
  43. SolaX X1-MINI G4 Priority 8

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The exact V1.7 Australian datasheet lists IEC 62109-1/-2, IEC 61727, EN 50549, G98, G99, AS 4777.2, VDE-AR-N 4105, CEI 0-21 and VFR.; The current CER approved-inverter export checked 4 October 2026 lists the eight exact X1-MINI G4 AS4777-2 2020 configurations under SolaX Power Network Technology (Zhe jiang) Co Ltd, approved 13 May 2023 and expiring 25 October 2026. No renewal beyond that date is established. The full export contains no exact X1-MINI-0.8K-G4 (AS4777-2 2020) row; that manufacturer-published adjacent bin remains excluded.
    Warranty
    Australia; the current linked SolaX warranty PDF explicitly names X1-MINI-0.6K/0.7K/1.1K/1.5K/2.0K/2.5K/3K/3.3K-G4 for 12 years. Authorised supply, installation, activation and registration conditions apply.
    Grid compatibility
    Single-phase 220/230/240 V on-grid string-inverter family. The exact queued Australian approval identities carry the AS4777-2 2020 suffix. DNSP acceptance and export settings remain site-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  44. Tesla Powerwall 3 Integrated Inverter Priority 8

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    AS/NZS 4777.2; IEC 62109-1/-2; IEC 62619; UL 9540A unit-level fire test; The Clean Energy Regulator export of the CEC approved inverter list (captured 29 September 2026, source file modified 24 September 2026) lists Tesla Inc series 1707000-xx-y (Powerwall 3 with Backup Gateway 2), model 1707000-11.04 kVA (AS4777-2 2020), 11.04 kW, approved 17 October 2024 and expiring 17 October 2027. The 5 kVA and 10 kVA configurations carry the same dates. Rows for the series 'Powerwall 3 and Expansions with Backup Gateway 2' were approved 19 August 2025 and expire 31 December 2027.
    Warranty
    The Tesla Powerwall Warranty (Australia and New Zealand), Rev. 1.17 effective 3 September 2026, names Powerwall 3 part number 1707000-xx-x and is given by Tesla Motors Netherlands B.V. The term is 10 years from initial installation, with 70% of the 13.5 kWh rated capacity retained at 10 years: unlimited cycles for solar self-consumption or time-based control, and backup, or 37.8 MWh aggregate throughput for any other application (page 1). The integrated solar inverter is part of the Powerwall 3 system rather than a separately warrantied standalone inverter.
    Grid compatibility
    Single-phase 230 V integrated system certified for Australia and New Zealand. Tesla publishes 5 kW, 10 kW and 11.04 kW configured outputs, with the final on-grid limit dependent on local conditions and approved system design.
    Safety and source
    No model-specific notice recorded
    regional source
  45. Enphase IQ8HC Microinverter Priority 9

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    AS/NZS 4777.2:2020 + A2, EN IEC 62109-1, EN IEC 62109-2 and RCM for IQ8HC-72-M-INT.; The current CER approved-inverter export checked 4 October 2026 lists exact IQ8HC-72-M-INT (AS4777-2 2020) under Enphase Energy Inc, approved 13 July 2023 and expiring 9 January 2027, at 0.38 kW AC. This extends the previously recorded 11 October 2026 expiry. Other regional suffixes are separate identities; approval does not establish installation-specific DNSP acceptance.
    Warranty
    Australia and New Zealand; the current terms provide 25 years for eligible IQ8HC-72-M-INT units, subject to activation and claim conditions.
    Grid compatibility
    IQ8HC-72-M-INT is the 230 V, 50 Hz Australian SKU and publishes AS/NZS 4777.2:2020 + A2 compliance with IQ Relay.
    Safety and source
    No model-specific notice recorded
    regional source
  46. SOFAR PowerAll ESI 3-6K-S1 Priority 9

    Buyer-ready100% sourced

    Local availability, buyer evidence, and the publication threshold are confirmed.

    Certification
    The exact ESI 3-6K-S1 manual lists IEC 62109-1/-2 and AS/NZS 4777 alongside several additional national grid standards.
    Warranty
    SOFAR Australia's published factory warranty (Version 2.5, updated 15 December 2025) covers ESI-series energy-storage inverters for 10 years and includes one freight to the end user plus labour and material needed to restore a functioning product, subject to the claim conditions. Version 2.4 (updated 1 May 2025) names ESI 3-6K-S1 at 120 months. Paid extension options are available.
    Grid compatibility
    The exact family supports Australian grid settings, a 0.8 leading-to-lagging power-factor range and demand-response controls. Final CEC product status, DNSP export limits, meter configuration and backup-circuit design remain installation-specific.
    Safety and source
    No model-specific notice recorded
    regional source
  47. GoodWe MS G3 Priority 12

    In review100% sourced

    A current regulator safety notice applies to this exact model.

    Certification
    Rechecked 29 August 2026: the current CER inverter export still lists GW5000-MS-30, GW6000-MS-30, GW8500-MS-30 and GW10K-MS-30 with the (AS4777-2 2020) suffix, approved 19 May 2023 and expiring 15 November 2026.; The CEC states that the (AS4777-2 2020) suffix denotes approval under an AS/NZS 4777.2:2020 certificate issued by a JAS-ANZ accredited certifier or state electrical regulator.
    Warranty
    Australia and New Zealand; MS G3 receives five years of limited inverter cover plus a further five years of spare-parts-only cover. The separate ten-year on-grid promotion requires eligible manufacture date, installation, registration and SEMS connection.
    Grid compatibility
    Single-phase 220, 230 or 240 V grid-connected string inverter family. Current CER listing does not remove the separate safety-recall obligation for affected units.
    Safety and source
    active
    regional source

Why the failures remain visible

A missing certification record is not converted into an assumption. A live safety notice is not buried under a strong score. A global product page is not treated as proof of Australian availability. The in-review rows show where a buyer still needs evidence and where the publication must continue researching.

What changes this report

A product can enter or leave the table when the Australian research priority changes. Its status moves only when a source establishes or removes a required field, when criterion-level source coverage crosses the publication threshold, or when a regulator notice changes state. Search-and-purchase proxies select the queue; they never affect score or readiness.

Sources and methodliving dataset

Read our ownership, funding and editorial disclosures.

Continue into the data

Scorecards cited in this finding.

41 more cited scorecards are linked at the findings they support in the article above.

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.