back to panels

Global Tier-1

Vega BVM7609M

395–415 W

Boviet SolarReleased 2024

61/ 100

Good

Global

BifacialGlass-Glass

The verdict. In our Global Tier-1 class, Boviet Solar Vega BVM7609M leads on architecture & design.

42thof 66 in Global Tier-1Lower halfclass average 63.8
Compare this panel →Ask Watt →

The assessment

How it scores, by category

Architecture & Design74
Efficiency & Yield52
Durability (verified)63
Performance & Degradation53
Guarantee & Backbone66
Sustainability55

Market position

42thof 66 in Global Tier-1Lower half
456176

Our reading

Vega BVM7609M scores 61, placing 42 of 66 in the Global Tier-1 class against a class average of 63.8. Its highest-scoring dimension is architecture & design (74), above the class average of 72. Efficiency & Yield scores 52, the lowest pillar for this product. The class average on efficiency & yield is 61. Underlying specifications include a module efficiency of 21.25%, 12-year product warranty backed by a 30-year performance term.

The data

Power
415W
Efficiency
21.25%
Cell
Not recorded
Temp coeff
-0.35%/°C
Technology architecture

Solar module

Architecture guide

Produces DC electricity at the roof. It contains no system-level power conversion or storage.

Product role
None in the module.
Published range
395–415 W
Electrical layer
DC module output
Construction
Not recorded
Architecture describes the product boundary. It is not a system design or an equipment-pairing decision.

Performance guarantee: 30-year linear output

415 Wrated347W at yr 30
7580859095100Guaranteed floor 83.5%Product 12yr83.5%0yr5yr10yr15yr20yr25yr30yr
Projected outputGuaranteed floor: 83.5% at yr 30Product warranty ends yr 12

Wattage figure based on the sourced rated power (415 W) applied to the guaranteed floor; modular/format differences aside, this is the same rated-power spec shown above.

Modelled effective output, year by year

355W312W

Year 1 to year 25, at 30°C and 1000 W/m². Rated 415 W at STC.

How this is modelled

Compounds this panel’s own published first-year (2%) and annual (0.5%/yr) degradation figures against its 415 W rated (STC) output, then derates for the ambient and irradiance selected. Output is scaled roughly linearly with irradiance (1000 W/m² against the 1000 W/m² STC reference). This is the dominant real-world effect at low light, whether from cloud, shading or soiling. Output is then further derated for heat, from this panel’s own NOCT (45°C) and temperature coefficient (-0.35%/°C), giving an estimated cell temperature of 61°C at that ambient and irradiance. A datasheet-derived estimate, not a field measurement or a warranty guarantee: it does not account for this panel’s own low-light efficiency response (a separate, less-consistently-published spec), or for wind and system design. See NOCT and temperature coefficient in the glossary.

Control panel

30°C
1000 W/m²
Year1510152025
Watts355 W348 W339 W330 W321 W312 W
% of rated85.6%83.8%81.6%79.5%77.3%75.1%
Before you buy
Local positionUse a market view to check local availability, approvals and warranty scope.
Ask the installerWill the quote name the exact Vega BVM7609M model and wattage, and who covers labour if the module warranty is used?

Verification & sources

Market context

Global evidencechange in the site menu

Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.

Benchmark anchor. California lists bins to 435 W that no Boviet datasheet documents; the series range is fixed to the documented 395 to 415 W and the scored bin is its maximum. Scored model: BVM7609M-415-H-HC-BF-DG · checked 2026-08-04. Evidence.

Sources & references · checked 2026-09-01

Strong evidence coverage

28 of 28 scored criteria link directly to a published source.

Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not a guarantee that a claim is correct.

How far the evidence reaches

2 of 5 questions with checkable rows have a row beyond the maker's claim.

  • Output1 of 6 checkable rows beyond the maker's claimMaker-only: 4 maker's commitments
  • Endurance1 of 7 checkable rows beyond the maker's claim
  • SafetyNot scored for panels
  • Backing2 checkable rows, none beyond the maker's claimMaker-only: 3 maker's commitments
  • Fit1 checkable row, not beyond the maker's claimMaker-only: 3 design facts
  • Footprint2 checkable rows, none beyond the maker's claim
  • Third-party source
  • Certified or regulator-listed
  • Manufacturer claim
  • Reviewed absence

Each bar is one question's checkable rows for this product at true share, stronger tiers first; hatching marks a reviewed absence: not published, we looked. Maker-only rows (warranty terms and design facts that rest on the maker's own documents) are counted under each question, never dropped. review.solar has measured none of these rows itself. How the evidence puzzle works

Record correction. Corrected 2026-10-23: Carbon footprint / EPD moves from 'Not published' to 'Carbon footprint / corporate ESG stated (no EPD)'. The row's own source, Boviet's EPD EPDITALY0800, covers a different product that shares the BVM7609M stem, the TOPCon BVM7609M-BF variant rated 400 to 440 W, not this PERC dual-glass model, so decision D5 of 22 October 2026 credits it at that band (55); the row had printed 'Not published'. Datasheet V7 of 14 January 2026, warranty BV-QA-15 revision A0 of 13 February 2024. First-market DE overlay review 2026-09-01: official German catalogues recorded; existing United States overlay and scores unchanged. Salt-mist evidence reviewed 4 October 2026: the exact 415 W PERC BF-DG V7 sheet dated 14 January 2026 is available through the official Inox Solar Americas host. It declares IEC 61701 salt-mist testing without a published severity level, certificate or report identifier, standard revision, test duration or measured loss. The declaration applies to this PERC BF-DG family; results from the TOPCon BF variant, BVM7612M or other power bins are not transferred. Corrected 2026-10-21: this note previously said existing Australian overlays were unchanged; the record carried none.

Change ledger

Product record history

7 changes to this record · 280 products changed in this update
  1. Record updated

    Carbon footprint / EPD: Evidence status

    Before
    Reviewed absence
    After
    Sourced
    Carbon footprint / EPDCarbon footprint / EPD
  2. Record updated

    PID (IEC TS 62804)

    Before
    Independently tested / certified
    After
    Third-party tested / certified
    PID (IEC TS 62804)
  3. Record updated

    Sustainability pillar score

    Before
    46.8
    After
    55
    Primary datasheet
  4. Record updated

    Source revision

    After this change
    Corrected 2026-10-23: Carbon footprint / EPD moves from 'Not published' to 'Carbon footprint / corporate ESG stated (no EPD)'. The row's own source, Boviet's EPD EPDITALY0800, covers a different product that shares the BVM7609M stem, the TOPCon BVM7609M-BF variant rated 400 to 440 W, not this PERC dual-glass model, so decision D5 of 22 October 2026 credits it at that band (55); the row had printed 'Not published'. Datasheet V7 of 14 January 2026, warranty BV-QA-15 revision A0 of 13 February 2024. First-market DE overlay review 2026-09-01: official German catalogues recorded; existing United States overlay and scores unchanged. Salt-mist evidence reviewed 4 October 2026: the exact 415 W PERC BF-DG V7 sheet dated 14 January 2026 is available through the official Inox Solar Americas host. It declares IEC 61701 salt-mist testing without a published severity level, certificate or report identifier, standard revision, test duration or measured loss. The declaration applies to this PERC BF-DG family; results from the TOPCon BF variant, BVM7612M or other power bins are not transferred. Corrected 2026-10-21: this note previously said existing Australian overlays were unchanged; the record carried none.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheet
  5. Record updated

    Third-party energy yield: Evidence sources

    Before
    https://scorecard.pvel.com/methodology/; https://scorecard.pvel.com/wp-content/uploads/2024-PV-Module-Reliability-Scorecard.pdf
    After
    https://scorecard.pvel.com/methodology/; https://web.archive.org/web/20250820221334/https://scorecard.pvel.com/wp-content/uploads/2024-PV-Module-Reliability-Scorecard.pdf
    Energy yield evidenceEnergy yield evidence+1 in JSON record
  6. Record updated

    Carbon footprint / EPD

    Before
    Not published
    After
    Carbon footprint / corporate ESG stated (no EPD)
    Carbon footprint / EPDCarbon footprint / EPD
  7. Record updated

    Global score

    Before
    60.4
    After
    60.9
    Primary datasheet
1 change to this record · 30 products changed in this update
  1. Record updated

    Source revision

    After this change
    Datasheet V7 of 14 January 2026, warranty BV-QA-15 revision A0 of 13 February 2024. First-market DE overlay review 2026-09-01: official German catalogues recorded; existing United States overlay and scores unchanged. Salt-mist evidence reviewed 4 October 2026: the exact 415 W PERC BF-DG V7 sheet dated 14 January 2026 is available through the official Inox Solar Americas host. It declares IEC 61701 salt-mist testing without a published severity level, certificate or report identifier, standard revision, test duration or measured loss. The declaration applies to this PERC BF-DG family; results from the TOPCon BF variant, BVM7612M or other power bins are not transferred. Corrected 2026-10-21: this note previously said existing Australian overlays were unchanged; the record carried none.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheet
1 change to this record · 30 products changed in this update
  1. Record updated

    Source revision

    After this change
    Datasheet V7 of 14 January 2026, warranty BV-QA-15 revision A0 of 13 February 2024. First-market DE overlay review 2026-09-01: official German catalogues recorded; existing United States overlay and scores unchanged. Salt-mist evidence reviewed 4 October 2026: the exact 415 W PERC BF-DG V7 sheet dated 14 January 2026 is available through the official Inox Solar Americas host. It declares IEC 61701 salt-mist testing without a published severity level, certificate or report identifier, standard revision, test duration or measured loss. The declaration applies to this PERC BF-DG family; results from the TOPCon BF variant, BVM7612M or other power bins are not transferred.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheet
1 change to this record · 22 products changed in this update
  1. Record updated

    Carbon footprint / EPD: Evidence sources

    Before
    https://www.epditaly.it/wp-content/uploads/2016/12/EPD-of-Boviet-Photovoltaic-Modules_20240828.pdf
    After
    https://bovietsolar.com/wp-content/uploads/Boviet-Solar_ESG-Report-2024.pdf; https://www.epditaly.it/wp-content/uploads/2016/12/EPD-of-Boviet-Photovoltaic-Modules_20240828.pdf
    Carbon footprint / EPDCarbon footprint / EPD
3 changes to this record · 9 products changed in this update
  1. Record updated

    US Warranty scope

    After this change
    United States; a 12-year product and 30-year performance warranty guaranteeing 98% after year one, 0.5% maximum annual decline and 83.5% at year 30. The remedy at Boviet's option is repair, replacement or residual market value, transportation is covered on documented and pre-approved claims, and installation, removal and reinstallation costs are excluded. Cover transfers while the modules remain at the original location. The warranty document's claims clause directs owners to an address and email listed in the document, but lists only the website, and no United States telephone number is published anywhere on Boviet's site, so the claim path runs through a web form. These figures follow the Double Glass warranty BV-QA-15. On 7 October 2026 Boviet's commercial and industrial product page listed this module code as single glass with a transparent back, although the code and the datasheet describe double glass, and linked the Transparent Back warranty BV-QA-16 instead; the file linked there states a 0.45% maximum annual decline and 84.95% at year 30, as the datasheet does, while the BV-QA-16 file on the product resources page states 0.5% and 83.5%. None of these warranty documents prints the model code, so which warranty governs this exact module is not publicly established.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    US market evidenceFinancial strength & warranty backing+3 in JSON record
  2. Record updated

    US Certifications

    After this change
    The datasheet certifies UL 61730, IEC 61215 and IEC 61730 with UL 61730 fire performance Type 29, and cites IEC TS 62804-1 PID testing. Boviet publishes no UL or IEC product certificates on its site, only SGS ISO management-system certificates.; The exact BVM7609M-415-H-HC-BF-DG is on the California Energy Commission PV Module List with UL 61730 safety certification, 415 W nameplate, described as a 108 half-cut cell double glass bifacial module, with a listing date of 11 December 2024; the whole 18-row family shares that date. The Commission's row (list read 7 October 2026, stated unchanged since 1 October 2026) records Voc 38.47 V, Isc 13.51 A, Vmp 32.37 V and Imp 12.83 A, which differ from the datasheet's 415 W column at STC of 37.86 V, 13.74 A, 32.16 V and 12.91 A; neither source explains the difference, and no electrical value from either source is scored here.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    US market evidenceFinancial strength & warranty backing+3 in JSON record
  3. Record updated

    US Support Note

    After this change
    Boviet's United States business was acquired by INOX Solar Americas, LLC, backed by INOX Clean Energy of the INOXGFL Group, in a transaction Boviet announced in May 2026 as an approximately 750 million dollar sale expressly motivated by foreign entity of concern alignment, with completion reported that month; the Vietnamese parent's exchange filing put the module company consideration at up to 254 million dollars with the cell project excluded, and the warranty on this product is still issued by the Vietnamese entity. Module assembly at Greenville, North Carolina began April 2025 at a stated 2 GW capacity, the datasheet carries both Made in USA and Made in Vietnam badges without saying which site builds which bin, the family EPD names the Vietnam plant, and the United States cell factory is unopened with commissioning expected by December 2026, so cells remain imported. Boviet's contact page, read on 7 October 2026, lists Inox Solar Americas headquarters and PV module and cell production at 1125 Sugg Parkway, Greenville, North Carolina and prints no other address; there is no installer or distributor locator.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    US market evidenceFinancial strength & warranty backing+3 in JSON record
6 changes to this record · 1 product changed in this update
  1. Record updated

    Salt mist (IEC 61701): Evidence status

    Before
    Reviewed absence
    After
    Sourced
    Salt mist (IEC 61701)Primary datasheet
  2. Record updated

    Global score

    Before
    59.5
    After
    60.4
    Primary datasheet
  3. Record updated

    Salt mist (IEC 61701)

    Before
    Not Listed
    After
    Certified (IEC 61701), severity not published
    Salt mist (IEC 61701)Primary datasheet
  4. Record updated

    Salt mist (IEC 61701): Evidence sources

    Before
    https://bovietsolar.com/wp-content/uploads/1_Vega_BVM7609M-395-415W-H-HC-BF-DG.pdf
    After
    https://inoxsolar.us/wp-content/uploads/1_Vega_BVM7609M-395-415W-H-HC-BF-DG.pdf
    Salt mist (IEC 61701)+1 in JSON record
  5. Record updated

    Durability (verified) pillar score

    Before
    58.5
    After
    62.6
    Primary datasheet
  6. Record updated

    Source revision

    After this change
    Datasheet V7 of 14 January 2026, warranty BV-QA-15 revision A0 of 13 February 2024. First-market DE overlay review 2026-09-01: official German catalogues recorded; existing Australian and United States overlays and scores unchanged. Salt-mist evidence reviewed 4 October 2026: the exact 415 W PERC BF-DG V7 sheet dated 14 January 2026 is available through the official Inox Solar Americas host. It declares IEC 61701 salt-mist testing without a published severity level, certificate or report identifier, standard revision, test duration or measured loss. The declaration applies to this PERC BF-DG family; results from the TOPCon BF variant, BVM7612M or other power bins are not transferred.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheet
5 changes to this record · 152 products changed in this update
  1. Record updated

    Source revision

    Before
    Datasheet V7 of 14 January 2026, warranty BV-QA-15 revision A0 of 13 February 2024
    After
    Datasheet V7 of 14 January 2026, warranty BV-QA-15 revision A0 of 13 February 2024. First-market DE overlay review 2026-09-01: official German catalogues recorded; existing Australian and United States overlays and scores unchanged.
    Primary datasheet
  2. Evidence added

    DE Support Note

    Before
    Not previously recorded
    After
    bovietsolar.com/de redirects to a global solutions page, not a German product catalogue, and does not name BVM7609M-415-H-HC-BF-DG.
    DE market evidenceDE market evidence
  3. Evidence added

    DE Certifications

    Before
    Not previously recorded
    After
    DE market evidenceDE market evidence
  4. Evidence added

    DE Evidence sources

    Before
    Not previously recorded
    After
    https://bovietsolar.com/de/; https://bovietsolar.com/solutions/designed-to-deliver
    DE market evidenceDE market evidence
  5. Evidence added

    DE Status

    Before
    Not previously recorded
    After
    unavailable
    DE market evidenceDE market evidence
2 changes to this record · 109 products changed in this update
  1. Record updated

    Global score

    Before
    59.2
    After
    59.5
    Primary datasheet
  2. Record updated

    Efficiency & Yield pillar score

    Before
    50.5
    After
    51.9
    Primary datasheet
5 changes to this record · 118 products changed in this update
  1. Record updated

    Efficiency & Yield pillar score

    Before
    47.9
    After
    50.5
    Primary datasheet
  2. Record updated

    Third-party energy yield: Evidence sources

    Before
    https://scorecard.pvel.com/top-performers/
    After
    https://scorecard.pvel.com/methodology/; https://scorecard.pvel.com/wp-content/uploads/2024-PV-Module-Reliability-Scorecard.pdf
    Energy yield evidencesupersededEnergy yield evidence+1 in JSON record
  3. Record updated

    Global score

    Before
    58.6
    After
    59.2
    Primary datasheet
  4. Record updated

    Third-party energy yield: Evidence status

    Before
    Reviewed absence
    After
    Sourced
    Energy yield evidencesupersededEnergy yield evidence+1 in JSON record
  5. Record updated

    Third-party energy yield

    Before
    Not independently yield-tested
    After
    Brand or series yield-tested; exact model not covered
    Energy yield evidencesupersededEnergy yield evidence+1 in JSON record
6 changes to this record · 65 products changed in this update
  1. Record updated

    Durability (verified) pillar score

    Before
    57.9
    After
    58.5
    Primary datasheet
  2. Evidence removed

    Encapsulant chemistry: Evidence sources

    Before
    https://bovietsolar.com/wp-content/uploads/1_Vega_BVM7609M-395-415W-H-HC-BF-DG.pdf
    After
    No longer recorded
    Primary datasheet
  3. Record updated

    Architecture & Design pillar score

    Before
    75.7
    After
    73.9
    Primary datasheet
  4. Evidence removed

    Encapsulant chemistry: Evidence status

    Before
    Sourced
    After
    No longer recorded
    Primary datasheet
  5. Record updated

    Global score

    Before
    58.8
    After
    58.6
    Primary datasheet
  6. Evidence removed

    Encapsulant chemistry

    Before
    POE (polyolefin) both sides
    After
    No longer recorded
    Primary datasheet
9 changes to this record · 106 products changed in this update
  1. Record updated

    Architecture & Design pillar score

    Before
    71
    After
    75.7
    Primary datasheet
  2. Evidence removed

    Damp heat extended (2000h)

    Before
    1000h IEC 61215 standard
    After
    No longer recorded
    Primary datasheet
  3. Evidence removed

    Awards

    Before
    Not Listed
    After
    No longer recorded
    Primary datasheet
  4. Evidence removed

    Damp heat extended (2000h): Evidence sources

    Before
    https://bovietsolar.com/wp-content/uploads/1_Vega_BVM7609M-395-415W-H-HC-BF-DG.pdf
    After
    No longer recorded
    Primary datasheet
  5. Evidence removed

    Damp heat extended (2000h): Evidence status

    Before
    Sourced
    After
    No longer recorded
    Primary datasheet
  6. Evidence removed

    Awards: Evidence status

    Before
    Reviewed absence
    After
    No longer recorded
    Primary datasheet
  7. Record updated

    Global score

    Before
    58
    After
    58.8
    Primary datasheet
  8. Record updated

    Durability (verified) pillar score

    Before
    58.3
    After
    57.9
    Primary datasheet
  9. Evidence removed

    Awards: Evidence sources

    Before
    https://bovietsolar.com/wp-content/uploads/1_Vega_BVM7609M-395-415W-H-HC-BF-DG.pdf
    After
    No longer recorded
    Primary datasheet

This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.

Evidence timeline

Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.

  1. Core scorecard evidence checked
  2. DE market evidence checked
  3. US market evidence checked
  4. Series benchmark evidence checked

Evidence record (JSON)

Scored by Solar Analytica Research

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.