The assessment
How it scores, by category
Market position
The data
Hybrid inverter
Manages PV, battery DC and household AC through the inverter platform.
- Product role
- The battery remains a separate product even when it belongs to the same branded platform.
- Published range
- 7–10.5 kW
- Phase
- Single phase
- Backup boundary
- Essential-load capability recorded
What the documents establish
Published evidence, source-reviewed non-disclosure and unresolved questions remain separate from the product score.
Warranty coverage: 10-year term
Coverage includes
Parts only · term longer than 24 of 95 scored inverters
No inverter in the fleet publishes a year-by-year performance or output guarantee the way panels and batteries do - this shows the covered term against the market-typical term and where every scored inverter’s term lands (grey dots, sized by model count), plus what the warranty actually includes.
Verification & sources
Market context
Global evidencechange in the site menu
Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.
Benchmark anchor. The score is anchored to KH10.5, the highest rated hybrid model in the Australian KH 7 to 10.5 kW series. The KA AC-coupled sibling is not included. Scored model: KH10.5 · checked 2026-07-27. Evidence.
Sources & references · checked 2026-08-30
Strong evidence coverage
26 of 26 scored criteria link directly to a published source.
Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.
How far the evidence reaches
- OutputManufacturer claim4 rows in the rings
- EnduranceCertified or regulator-listed1 of 2 rows in the rings beyond claim2 design facts beside the rings
- SafetyCertified or regulator-listed1 of 2 rows in the rings beyond claim
- BackingManufacturer claim1 row in the rings2 warranty terms beside the rings
- FitManufacturer claim4 rows in the rings9 design facts beside the rings
- FootprintNot assessed for inverters
Rings, outside in: manufacturer claim, certified or regulator-listed, third-party source. The centre is review.solar's own measurement, empty for every product today. Warranty terms and design facts that rest on the maker's own word are counted beside the rings; a reviewed absence, or one that reaches beyond the maker's claim, stays in them. How the evidence puzzle works
Record revision. FoxESS KH/KA AU datasheet V1.6, 2025-10-09; AU inverter warranty V3.4; AU inverter outage-reality evidence checked 2026-08-06; AU residential inverter operating-reality evidence checked 2026-08-06. First-market US and DE overlay review 2026-08-30: official regional catalogues recorded; Australian overlays and scores unchanged. Thermal interface evidence reviewed 5 October 2026: KH/KA manual V1.0.6 names KH10.5 and documents K1/K2 and K3/K4 dry contacts or external heat-pump control signals. Surplus-triggered operation, SG-Ready state mapping, timer scheduling, firmware/accessory conditions and contact ratings remain unestablished in the reviewed evidence. Hardware disclosure does not establish a complete thermal-control function; existing assessment retained pending exact operating evidence. Firmware/security disclosure reviewed 5 October 2026: public FoxESS policy V1.0 (July 2026) explicitly covers inverters and device firmware; KH disclosure band updated from 55 to 80. No signing, secure boot or exact KH support lifetime inferred.
- Sourced valuesData card →
- Warranty summary10-year product warranty →
Show 5 more
- Backup / islandingManufacturer ↗
- Grid & safety certificationManufacturer ↗
- Manufacturing track recordManufacturer ↗
- Smart home & IoT depthManufacturer ↗
- Firmware & security disclosureManufacturer ↗
Help strengthen this record
These are published evidence gaps, not private submissions. A source is reviewed under the same methodology whether it comes from a reader, installer or manufacturer.
- Semiconductor technologyNot stated in reviewed documentsThe public documents reviewed for this record do not state this value. A published or independent source is requested.Offer a source
- EV charging integrationNot stated in reviewed documentsThe public documents reviewed for this record do not state this value. A published or independent source is requested.Offer a source
- Thermal load managementNot stated in reviewed documentsThe public documents reviewed for this record do not state this value. A published or independent source is requested.Offer a source
Product record history
One earlier entry recorded a source recheck rather than a change to the published figure, and is not listed here. Every entry remains in the evidence record.
2 changes to this record · 19 products changed in this update
Semiconductor technology: Evidence sources
- Before
- https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/products/hybrid-inverter/kh-series
- After
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260828/ENKHKADatasheetAUV1.620260820.pdf; https://au.fox-ess.com/products/hybrid-inverter/35
Semiconductor technology: Evidence status
- Before
- sourced
- After
- reviewed_absence
1 change to this record · 43 products changed in this update
Grid & safety certification: Evidence sources
- Before
- https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/wp-content/uploads/2025/08/EN-KH-KA-DatasheetAU-V1.5-20250509.pdf
- After
- https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/wp-content/uploads/2025/08/EN-KH-KA-DatasheetAU-V1.5-20250509.pdf; https://cer.gov.au/document/cec-approved-inverters-0
9 changes to this record · 10 products changed in this update
AU Warranty scope
- Current text
- FoxESS Australia's inverter warranty policy names KH7, KH8, KH9, KH9.9, KH10 and KH10.5 and provides 120 months from installation, capped at 132 months from manufacture, whichever comes first (Version 4.0, 1 April 2026, clause iii). That is the version listed on FoxESS Australia's downloads page on 7 October 2026. Service and transport rebates are conditional (clause v). Version 3.4 (1 October 2024) also required annual inspection by an authorised technician from the sixth year; Version 4.0 states no annual-inspection condition. Neither document states which version applies to a given installation.
The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.
AU market evidenceControl plane+7 in JSON recordEvidence sources
- Before
- https://au.fox-ess.com/news/24
- After
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260514/105001007306XKHUserManualENV1.0.620260512.pdf; https://au.fox-ess.com/news/24
AU Warranty conditions
- Current text
- labour: The warranty does not establish an uncapped owner-selected labour entitlement; approved service is subject to FoxESS processes and limits.; registration: Version 4.0 (1 April 2026) no longer contains the registration clause that Version 3.4 carried as clause viii. Its FoxPlus clause refers to registration on the FoxESS website within 36 months of manufacture and cites section 8, which in Version 4.0 is the claim process. The claim process (clause viii) requires the installer to supply the model, fault code, fault details and an RMA form with evidence.; remedy: FoxESS may repair or replace an approved defective product under the governing terms.; removal reinstallation: No uncapped removal and reinstallation entitlement was established in the governing terms.; transferability: No express subsequent-owner transfer right was found in the governing Australian inverter warranty.; transport: Transport support is subject to the governing claim process and exclusions; no uncapped transport entitlement is stated.
The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.
AU market evidenceControl plane+7 in JSON recordAU Certifications
- Before
- The current Australian approved-inverter export lists FOXESS KH10.5 (AS4777-2 2020) from 13 June 2025 to 13 June 2028.
- After
- The Australian approved-inverter export (CER) lists KH7, KH8, KH9, KH9.9, KH10 and KH10.5, each to AS4777-2 2020, from 13 June 2025 to 13 June 2028.
AU Evidence sources
- Before
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260615/-659.pdf; https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/resource-support/vulnerability-disclosure-and-handling-policy; https://au.fox-ess.com/wp-content/uploads/2025/08/EN-KH-KA-DatasheetAU-V1.5-20250509.pdf; https://cer.gov.au/document/cec-approved-inverters; https://www.ausnetservices.com.au/-/media/project/ausnet/corporate-website/files/renewable-solutions/industry/approved-inverters/ausnet-interoperable-csip-scc-inverter-combinations-22042026.pdf?rev=d5ef6721ae064ab8a36d6b9d8b73514d
- After
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260514/105001007306XKHUserManualENV1.0.620260512.pdf; https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260615/-659.pdf; https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260828/ENKHKADatasheetAUV1.620260820.pdf; https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260901/INVERTERWARRANTYAU.pdf; https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/resource-support/vulnerability-disclosure-and-handling-policy; https://au.fox-ess.com/wp-content/uploads/2025/08/EN-KH-KA-DatasheetAU-V1.5-20250509.pdf; https://cer.gov.au/document/cec-approved-inverters; https://www.ausnetservices.com.au/-/media/project/ausnet/corporate-website/files/renewable-solutions/industry/approved-inverters/ausnet-interoperable-csip-scc-inverter-combinations-22042026.pdf?rev=d5ef6721ae064ab8a36d6b9d8b73514d
Warranty period (yrs): Evidence sources
- Before
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260615/-659.pdf; https://au.fox-ess.com/products/hybrid-inverter/35
- After
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260615/-659.pdf; https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260901/INVERTERWARRANTYAU.pdf; https://au.fox-ess.com/products/hybrid-inverter/35
Value
- Before
- FoxESS states that KH frequency-shift capability enables battery charging during power outages.
- After
- The KH/KA user manual V1.0.6 (PDF page 6) states that when the grid is off the system supplies emergency power from PV or battery to the home loads, with a battery required in EPS mode. It does not state that PV recharges the battery during an outage. The FoxESS news item of 3 November 2025 lists frequency-shift charging during outages among H3 Smart features and does not state it for the KH series.
Warranty assurance: Evidence sources
- Before
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260615/-659.pdf; https://au.fox-ess.com/products/hybrid-inverter/35
- After
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260615/-659.pdf; https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260901/INVERTERWARRANTYAU.pdf; https://au.fox-ess.com/products/hybrid-inverter/35
7 changes to this record · 1 product changed in this update
Firmware & security disclosure
- Before
- Firmware updates referenced; no security documentation
- After
- Security page or vulnerability disclosure published
Firmware & security disclosure: Evidence sources
- Before
- https://au.fox-ess.com/products/hybrid-inverter/35
- After
- https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/resource-support/vulnerability-disclosure-and-handling-policy
AU Evidence sources
- Before
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260615/-659.pdf; https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/wp-content/uploads/2025/08/EN-KH-KA-DatasheetAU-V1.5-20250509.pdf; https://cer.gov.au/document/cec-approved-inverters; https://www.ausnetservices.com.au/-/media/project/ausnet/corporate-website/files/renewable-solutions/industry/approved-inverters/ausnet-interoperable-csip-scc-inverter-combinations-22042026.pdf?rev=d5ef6721ae064ab8a36d6b9d8b73514d
- After
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260615/-659.pdf; https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/resource-support/vulnerability-disclosure-and-handling-policy; https://au.fox-ess.com/wp-content/uploads/2025/08/EN-KH-KA-DatasheetAU-V1.5-20250509.pdf; https://cer.gov.au/document/cec-approved-inverters; https://www.ausnetservices.com.au/-/media/project/ausnet/corporate-website/files/renewable-solutions/industry/approved-inverters/ausnet-interoperable-csip-scc-inverter-combinations-22042026.pdf?rev=d5ef6721ae064ab8a36d6b9d8b73514d
AU Support Note
- Before
- The 10.5 kW highest Australian model in the KH series now has exact current approval evidence.
- After
- The 10.5 kW highest Australian model in the KH series now has exact current approval evidence. FoxESS publishes a vulnerability-reporting and handling policy covering its inverters and firmware. A KH-specific security support end date, firmware signing and secure boot are not established by that policy.
Source revision
- Current text
- FoxESS KH/KA AU datasheet V1.6, 2025-10-09; AU inverter warranty V3.4; AU inverter outage-reality evidence checked 2026-08-06; AU residential inverter operating-reality evidence checked 2026-08-06. First-market US and DE overlay review 2026-08-30: official regional catalogues recorded; Australian overlays and scores unchanged. Thermal interface evidence reviewed 5 October 2026: KH/KA manual V1.0.6 names KH10.5 and documents K1/K2 and K3/K4 dry contacts or external heat-pump control signals. Surplus-triggered operation, SG-Ready state mapping, timer scheduling, firmware/accessory conditions and contact ratings remain unestablished in the reviewed evidence. Hardware disclosure does not establish a complete thermal-control function; existing assessment retained pending exact operating evidence. Firmware/security disclosure reviewed 5 October 2026: public FoxESS policy V1.0 (July 2026) explicitly covers inverters and device firmware; KH disclosure band updated from 55 to 80. No signing, secure boot or exact KH support lifetime inferred.
The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.
Control plane
2 changes to this record · 1 product changed in this update
Thermal load management: Evidence sources
- Before
- https://au.fox-ess.com/products/hybrid-inverter/35
- After
- https://au.fox-ess.com/Public/Uploads/uploadfile/files/20260514/105001007306XKHUserManualENV1.0.620260512.pdf
Source revision
- Current text
- FoxESS KH/KA AU datasheet V1.6, 2025-10-09; AU inverter warranty V3.4; AU inverter outage-reality evidence checked 2026-08-06; AU residential inverter operating-reality evidence checked 2026-08-06. First-market US and DE overlay review 2026-08-30: official regional catalogues recorded; Australian overlays and scores unchanged. Thermal interface evidence reviewed 5 October 2026: KH/KA manual V1.0.6 names KH10.5 and documents K1/K2 and K3/K4 dry contacts or external heat-pump control signals. Surplus-triggered operation, SG-Ready state mapping, timer scheduling, firmware/accessory conditions and contact ratings remain unestablished in the reviewed evidence. Hardware disclosure does not establish a complete thermal-control function; existing assessment retained pending exact operating evidence.
The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.
Control plane
9 changes to this record · 12 products changed in this update
DE Support Note
- Before
- Not previously recorded
- After
- A leftover German KH/KA datasheet names KH10.5. The live German hybrid catalogue cards show H1/AC1, H3 Smart, H3-M, H3 PRO and H3 Plus, not KH. The AU-style /35 product URL returns 404. Remaining-stock availability is not inferred from a leftover datasheet.
US Status
- Before
- Not previously recorded
- After
- unavailable
DE Status
- Before
- Not previously recorded
- After
- unavailable
US Evidence sources
- Before
- Not previously recorded
- After
- https://au.fox-ess.com/products/hybrid-inverter/35; https://us.fox-ess.com/; https://us.fox-ess.com/downloads/
US Support Note
- Before
- Not previously recorded
- After
- FoxESS USA lists US Series, PowerQ, H3 Plus and CQ7-US. It does not list KH10.5. KH is not H1 G2 and not H3-Pro.
DE Evidence sources
- Before
- Not previously recorded
- After
- https://au.fox-ess.com/products/hybrid-inverter/35; https://de.fox-ess.com/Public/Uploads/uploadfile/files/20260228/DEKHKADatasheetV1.420250307.pdf; https://de.fox-ess.com/produkte/hybrid-wechselrichter; https://de.fox-ess.com/produkte/hybrid-wechselrichter/35
Source revision
- Before
- FoxESS KH/KA AU datasheet V1.6, 2025-10-09; AU inverter warranty V3.4; AU inverter outage-reality evidence checked 2026-08-06; AU residential inverter operating-reality evidence checked 2026-08-06
- After
- FoxESS KH/KA AU datasheet V1.6, 2025-10-09; AU inverter warranty V3.4; AU inverter outage-reality evidence checked 2026-08-06; AU residential inverter operating-reality evidence checked 2026-08-06. First-market US and DE overlay review 2026-08-30: official regional catalogues recorded; Australian overlays and scores unchanged.
4 changes to this record · 73 products changed in this update
Value
- Before
- Not previously recorded
- After
- Direct-pv hybrid inverter with 4 independent MPPTs at the scored model boundary.
Evidence sources
- Before
- Not previously recorded
- After
- https://au.fox-ess.com/products/hybrid-inverter/35; https://au.fox-ess.com/wp-content/uploads/2025/08/EN-KH-KA-DatasheetAU-V1.5-20250509.pdf
This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.
Evidence timeline
Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.
- AU market evidence checked
- Plain-language warranty summary checked
- Core scorecard evidence checked
- US market evidence checked
- DE market evidence checked
- Australian certification source identity verified
- Series benchmark evidence checked
Scored by Solar Analytica Research
Further reading from Findings
Stay across the benchmark.
New scorecards, score changes and market signals, published as they happen.
Our reading
KH scores 74, placing 6 of 25 in the Value & Volume class against a class average of 72.1. Its strongest scoring dimension is design & flexibility (92), running 10.0 points above the class average on this dimension. Energy Ecosystem (48) is the dimension with the most room to move. Key specifications: 97.8% peak efficiency, 4 MPPT inputs, 10-year warranty.
Dietreich Farquharson · review.solar