back to panels

Global Tier-1

210R 66P

605–630 W · 66-cell · N-type TOPCon · Bifacial · Dual-glass

TCL SolarReleased 2023

61/ 100

Good

Global

BifacialGlass-Glass

The verdict. In our Global Tier-1 class, TCL Solar 210R 66P leads on performance & degradation.

37thof 60 in Global Tier-1Lower halfclass average 64.0
Compare this panelAsk Watt →

The assessment

How it scores, by category

Architecture & Design72
Efficiency & Yield60
Durability (verified)50
Performance & Degradation73
Guarantee & Backbone55
Sustainability48

Market position

37thof 60 in Global Tier-1Lower half
456174

Our reading

210R 66P scores 61, placing 37 of 60 in the Global Tier-1 class against a class average of 64.0. Its strongest scoring dimension is performance & degradation (73). Sustainability scores 48, the lowest pillar for this product. The class average on sustainability is 61. Underlying specifications include a module efficiency of 23.3%, N-type TOPCon cell technology, 15-year product warranty backed by a 30-year performance term.

The data

Power
630W
Efficiency
23.3%
Cell
N-type TOPCon
Temp coeff
-0.28%/°C
Technology architecture

N-type TOPCon module

Architecture guide

Produces DC electricity at the roof. It contains no system-level power conversion or storage.

Product role
None in the module.
Published range
605–630 W
Electrical layer
DC module output
Construction
Bifacial, Dual-glass
Architecture describes the product boundary. It is not a system design or an equipment-pairing decision.

Performance guarantee: 30-year linear output

630 Wrated551W at yr 30
80859095100Guaranteed floor 87.4%Product 15yr87.4%0yr5yr10yr15yr20yr25yr30yr
Projected outputGuaranteed floor: 87.4% at yr 30Product warranty ends yr 15

Wattage figure based on the sourced rated power (630 W) applied to the guaranteed floor; modular/format differences aside, this is the same rated-power spec shown above.

Modelled effective output, year by year

624W563W

Year 1 to year 25. Rated 630 W at STC.

How this is modelled

Modelled from this panel’s own published first-year (1%) and annual (0.4%/yr) degradation figures, compounded against its 630 W rated (STC) output. This is a datasheet-derived estimate, not a field measurement or a warranty guarantee. Actual output also depends on site irradiance, temperature, soiling and system design.

Year1510152025
Watts624 W614 W601 W588 W576 W563 W
% of rated99.0%97.4%95.4%93.4%91.4%89.4%
Before you buy
Local positionUse a market view to check local availability, approvals and warranty scope.
Ask the installerWill the quote name the exact 210R 66P model and wattage, and who covers labour if the module warranty is used?

Verification & sources

Market context

Global evidencechange in the site menu

Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.

Benchmark anchor. The score uses the 630 W top bin in the current 605-630 W exact series. Scored model: HSM-ND66-GR630 · checked 2026-08-21. Evidence.

Sources & references · checked 2026-09-02

Strong evidence coverage

24 of 24 scored criteria link directly to a published source.

Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.

Record revision. TCL exact combined sheet and official brochure rechecked 2026-08-23; fire and degradation are linked and unsupported MBB detail withheld. The undated, unversioned source limitation remains explicit. India existing-catalogue panel ALMM review 2026-09-02: IN overlays recorded against List-I revision 03.08.2026; scores unchanged.

Change ledger

Product record history

5 changes to this record · 28 products changed in this update
  1. Evidence added

    IN Status

    Before
    Not previously recorded
    After
    unavailable
    IN market evidenceIN market evidence
  2. Evidence added

    IN Support Note

    Before
    Not previously recorded
    After
    The exact scored model HSM-ND66-GR630 is not named on ALMM List-I revision 03.08.2026. ALMM is a domestic-content and procurement instrument; absence is not a quality finding and does not change the global score. A manufacturer catalogue is not a substitute for List-I. Existing AU, US, DE or EU warranty terms are not transferred. The catalogue family is HSM-ND66-GR605~630. HSM-ND48 and HSM-BE54 are different identities and are not transferred.
    IN market evidenceIN market evidence
  3. Record updated

    Source revision

    Before
    TCL exact combined sheet and official brochure rechecked 2026-08-23; fire and degradation are linked and unsupported MBB detail withheld. The undated, unversioned source limitation remains explicit.
    After
    TCL exact combined sheet and official brochure rechecked 2026-08-23; fire and degradation are linked and unsupported MBB detail withheld. The undated, unversioned source limitation remains explicit. India existing-catalogue panel ALMM review 2026-09-02: IN overlays recorded against List-I revision 03.08.2026; scores unchanged.
    Primary datasheet
  4. Evidence added

    IN Certifications

    Before
    Not previously recorded
    After
    The exact scored model HSM-ND66-GR630 is not named on ALMM List-I revision 03.08.2026. Cited source_version in-almm-module-2026-08-03-ffdfc4d1f767.
    IN market evidenceIN market evidence
  5. Evidence added

    IN Evidence sources

    Before
    Not previously recorded
    After
    https://cdnbbsr.s3waas.gov.in/s3716e1b8c6cd17b771da77391355749f3/uploads/2026/08/202608031426164762.pdf; https://mnre.gov.in/en/approved-list-of-models-and-manufacturers-almm/
    IN market evidenceIN market evidence
2 changes to this record · 109 products changed in this update
  1. Record updated

    Efficiency & Yield pillar score

    Before
    62.8
    After
    60
    Primary datasheet
  2. Record updated

    Global score

    Before
    61.7
    After
    61.2
    Primary datasheet
5 changes to this record · 118 products changed in this update
  1. Record updated

    Independent energy yield

    Before
    Brand or series yield-tested; exact model not covered
    After
    No public independent yield result found in reviewed sources
    Independent energy yieldIndependent energy yield+3 in JSON record
  2. Record updated

    Independent energy yield: Evidence sources

    Before
    https://scorecard.pvel.com/manufacturers/
    After
    https://scorecard.pvel.com/methodology/; https://scorecard.pvel.com/top-performers/; https://scorecard.pvel.com/wp-content/uploads/2022-PVEL-PV-Module-Reliability-Scorecard-Summary.pdf; https://scorecard.pvel.com/wp-content/uploads/2024-PV-Module-Reliability-Scorecard.pdf
    Independent energy yieldIndependent energy yield+3 in JSON record
  3. Record updated

    Efficiency & Yield pillar score

    Before
    65.4
    After
    62.8
    Primary datasheet
  4. Record updated

    Global score

    Before
    62.2
    After
    61.7
    Primary datasheet
  5. Record updated

    Independent energy yield: Evidence status

    Before
    sourced
    After
    reviewed_absence
    Independent energy yieldIndependent energy yield+3 in JSON record
8 changes to this record · 34 products changed in this update
  1. Record updated

    Annual degradation (%/yr): Evidence sources

    Before
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-brochure-en.pdf; https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetFire classification (IEC 61730)
  2. Evidence removed

    Contact: Evidence status

    Before
    sourced
    After
    No longer recorded
    Primary datasheet
  3. Record updated

    Architecture & Design pillar score

    Before
    81.8
    After
    72.4
    Primary datasheet
  4. Record updated

    Source revision

    Before
    TCL T Class 66 HSM-ND66-GR610-630 datasheet January 2026 and current resource library, rechecked 2026-08-01 Re-verification 2026-08-19: Verified reliability recorded as "Brand or series independently tested; exact model not covered" under panel rubric v2.13.0, which added a band for brand or series evidence where the exact model is not covered by the third-party record. Re-verification 2026-08-20: Independent energy yield recorded as brand-or-series under panel rubric v2.14.0, which applied to this criterion the same exact-model rule v2.13.0 applied to Verified reliability. Identity and AU evidence closure 2026-08-21: current global family is 605-630 W; exact 630 W is CER-listed, while local stock and warranty remain unestablished.
    After
    TCL exact combined sheet and official brochure rechecked 2026-08-23; fire and degradation are linked and unsupported MBB detail withheld. The undated, unversioned source limitation remains explicit.
    Primary datasheet
  5. Record updated

    Fire classification (IEC 61730): Evidence sources

    Before
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-brochure-en.pdf; https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetFire classification (IEC 61730)
  6. Evidence removed

    Contact: Evidence sources

    Before
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    After
    No longer recorded
    Primary datasheet
  7. Evidence removed

    Contact

    Before
    MBB Wire front contact
    After
    No longer recorded
    Primary datasheet
  8. Record updated

    Global score

    Before
    64
    After
    62.2
    Primary datasheet
29 changes to this record · 6 products changed in this update
  1. Record updated

    Cell technology tier: Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  2. Record updated

    AU Certifications

    Before
    After
    The current CER export lists exact HSM-ND66-GR630 through 6 October 2028 under certificate holder Huansheng Photovoltaic (Jiangsu) Co Ltd.
    Primary datasheetPrimary datasheet+2 in JSON record
  3. Record updated

    Range Label

    Before
    610–630 W
    After
    605–630 W
    Primary datasheetPrimary datasheet
  4. Record updated

    Guarantee period (yrs): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  5. Record updated

    Salt mist (IEC 61701): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  6. Record updated

    AU Support Note

    Before
    TCL's current resource library places T Class 66 in its European range and publishes different T5 Pro and C2 families for Australia. Exact Australian sale, approval and warranty remain unproven.
    After
    The exact 630 W bin is regulator-listed in Australia. TCL's Australian resource library does not publish the T Class 66 sale path, current stock or a governing local warranty, so approval is recorded without converting it into an availability claim.
    Primary datasheetPrimary datasheet+2 in JSON record
  7. Record updated

    Negative loading (MQT16, Pa): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  8. Record updated

    Ammonia resistance (IEC 62716): Evidence sources

    Before
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheet
  9. Record updated

    Guarantee assurance: Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf; https://www.tclsolar.com/resources
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf; https://www.tclsolar.com/resources
    Primary datasheetPrimary datasheet+1 in JSON record
  10. Record updated

    Model

    Before
    HSM-ND66-GR610~630
    After
    HSM-ND66-GR605~630
    Primary datasheetPrimary datasheet
  11. Record updated
  12. Record updated

    Positive loading (MQT16, Pa): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  13. Record updated

    PID (IEC TS 62804): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  14. Record updated

    Bifaciality factor (%): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  15. Record updated

    Guaranteed end-of-warranty output (%): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  16. Record updated

    Ranges

    Current text
    checked: 2026-08-21; market: global; max: 630; min: 605; range label: 605–630 W; source revision: Official current HSM-ND66-GR605-630 family datasheet; source url: https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf; unit: W

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheetPrimary datasheet
  17. Record updated

    Temp coefficient Pmax (%/C): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  18. Record updated

    Contact: Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  19. Record updated

    First-year degradation (%): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  20. Record updated

    Note

    Before
    The score uses the 630 W top bin in the current 610-630 W exact series.
    After
    The score uses the 630 W top bin in the current 605-630 W exact series.
    Primary datasheetPrimary datasheet
  21. Record updated

    Power tolerance (%): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  22. Record updated

    Encapsulation & frame construction: Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  23. Record updated

    Performance guarantee period (yrs): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  24. Record updated

    AU Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf; https://www.tclsolar.com/resources
    After
    https://cer.gov.au/document/cec-approved-pv-modules-0; https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf; https://www.tclsolar.com/resources
    Primary datasheetPrimary datasheet+2 in JSON record
  25. Record updated

    Ammonia resistance (IEC 62716): Evidence status

    Before
    derived
    After
    reviewed_absence
    Primary datasheet
  26. Record updated

    Module efficiency (%): Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  27. Record updated

    Source

    Current text
    checked: 2026-08-21; source revision: Official current HSM-ND66-GR605-630 family datasheet; source url: https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheetPrimary datasheet
  28. Record updated

    Primary Source

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf
    After
    https://www.tcl.com/content/dam/brandsite/region/global/guangfu/residential-pv-system/document/tcl-residential-pv-system-datasheet-en.pdf
    Primary datasheetPrimary datasheet
  29. Record updated

    Source revision

    Current text
    TCL T Class 66 HSM-ND66-GR610-630 datasheet January 2026 and current resource library, rechecked 2026-08-01 Re-verification 2026-08-19: Verified reliability recorded as "Brand or series independently tested; exact model not covered" under panel rubric v2.13.0, which added a band for brand or series evidence where the exact model is not covered by the third-party record. Re-verification 2026-08-20: Independent energy yield recorded as brand-or-series under panel rubric v2.14.0, which applied to this criterion the same exact-model rule v2.13.0 applied to Verified reliability. Identity and AU evidence closure 2026-08-21: current global family is 605-630 W; exact 630 W is CER-listed, while local stock and warranty remain unestablished.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheetPrimary datasheet
7 changes to this record · 65 products changed in this update
  1. Record updated

    Source revision

    Current text
    TCL T Class 66 HSM-ND66-GR610-630 datasheet January 2026 and current resource library, rechecked 2026-08-01 Re-verification 2026-08-19: Verified reliability recorded as "Brand or series independently tested; exact model not covered" under panel rubric v2.13.0, which added a band for brand or series evidence where the exact model is not covered by the third-party record. Re-verification 2026-08-20: Independent energy yield recorded as brand-or-series under panel rubric v2.14.0, which applied to this criterion the same exact-model rule v2.13.0 applied to Verified reliability.

    The previous text is not reproduced here: both versions run to a full research paragraph. Both are in the JSON record linked below.

    Primary datasheet
  2. Record updated

    Rating

    Before
    Very good
    After
    Good
    Primary datasheet
  3. Record updated

    Global score

    Before
    65.8
    After
    64
    Primary datasheet
  4. Record updated

    Name Rating

    Before
    Very Good
    After
    Good
    Primary datasheet
  5. Record updated

    Durability (verified) pillar score

    Before
    51.9
    After
    50.1
    Primary datasheet
  6. Record updated

    Independent energy yield

    Before
    Field/PAN energy-yield validated
    After
    Brand or series yield-tested; exact model not covered
    Verified reliability
  7. Record updated

    Efficiency & Yield pillar score

    Before
    72.1
    After
    65.4
    Primary datasheet
4 changes to this record · 31 products changed in this update
  1. Record updated

    Durability (verified) pillar score

    Before
    59.9
    After
    51.9
    Primary datasheet
  2. Record updated

    Source revision

    Before
    TCL T Class 66 HSM-ND66-GR610-630 datasheet January 2026 and current resource library, rechecked 2026-08-01
    After
    TCL T Class 66 HSM-ND66-GR610-630 datasheet January 2026 and current resource library, rechecked 2026-08-01 Re-verification 2026-08-19: Verified reliability recorded as "Brand or series independently tested; exact model not covered" under panel rubric v2.13.0, which added a band for brand or series evidence where the exact model is not covered by the third-party record.
    Primary datasheet
  3. Record updated

    Global score

    Before
    67.6
    After
    65.8
    Primary datasheet
  4. Record updated

    Verified reliability

    Before
    Top Performer (current/partial)
    After
    Brand or series independently tested; exact model not covered
    Verified reliability
9 changes to this record · 106 products changed in this update
  1. Evidence removed

    Awards: Evidence sources

    Before
    https://pub-72985f516cf4462ebe2c3d69275b4a1e.r2.dev/datasheets/emea/en/tcl_tclass_HSM-ND66-GR610-630_gg_ds_en_a4_554358.pdf; https://www.tclsolar.com/resources
    After
    No longer recorded
    Primary datasheetGuarantee assurance
  2. Record updated

    Architecture & Design pillar score

    Before
    76.7
    After
    81.8
    Primary datasheet
  3. Evidence removed

    Damp heat extended (2000h)

    Before
    1000h IEC 61215 standard
    After
    No longer recorded
    No direct source binding recorded
  4. Record updated

    Global score

    Before
    66.8
    After
    67.6
    Primary datasheet
  5. Evidence removed

    Damp heat extended (2000h): Evidence sources

    Before
    After
    No longer recorded
    No direct source binding recorded
  6. Evidence removed

    Damp heat extended (2000h): Evidence status

    Before
    derived
    After
    No longer recorded
    No direct source binding recorded
  7. Evidence removed

    Awards

    Before
    Not Listed
    After
    No longer recorded
    Primary datasheetGuarantee assurance
  8. Record updated

    Durability (verified) pillar score

    Before
    60.5
    After
    59.9
    Primary datasheet
  9. Evidence removed

    Awards: Evidence status

    Before
    reviewed_absence
    After
    No longer recorded
    Primary datasheetGuarantee assurance

This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.

Evidence timeline

Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.

  1. Core scorecard evidence checked
  2. IN market evidence checked
  3. AU market evidence checked
  4. Series benchmark evidence checked
  5. DE market evidence checked

Evidence record (JSON)

Scored by Solar Analytica Research

Further reading from Findings

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.