back to panels

Global Tier-1

PANDA 3.0 Pro

575–600 W · 72-cell · N-type TOPCon · Bifacial · Dual-glass

Yingli

62/ 100

Good

Global

BifacialGlass-Glass

The verdict. In our Global Tier-1 class, Yingli PANDA 3.0 Pro leads on performance & degradation.

36thof 51 in Global Tier-1Lower halfclass average 65.4
Compare this panelAsk Watt →

The assessment

How it scores, by category

Architecture & Design68
Efficiency & Yield72
Durability (verified)50
Performance & Degradation73
Guarantee & Backbone46
Sustainability46

Market position

36thof 51 in Global Tier-1Lower half
466274

Our reading

PANDA 3.0 Pro scores 62, placing 37 of 51 in the Global Tier-1 class against a class average of 65.4. Its strongest scoring dimension is performance & degradation (73), above the class average of 73. Sustainability scores 46, the lowest pillar for this product. The class average on sustainability is 64. Underlying specifications include a module efficiency of 23.2%, N-type TOPCon cell technology, 12-year product warranty backed by a 30-year performance term.

The data

Power
600W
Efficiency
23.2%
Cell
N-type TOPCon
Temp coeff
-0.29%/°C
Technology architecture

N-type TOPCon module

Architecture guide

Produces DC electricity at the roof. It contains no system-level power conversion or storage.

Product role
None in the module.
Published range
575–600 W
Electrical layer
DC module output
Construction
Bifacial, Dual-glass
Architecture describes the product boundary. It is not a system design or an equipment-pairing decision.

Performance guarantee: 30-year linear output

600 Wrated524W at yr 30
80859095100Guaranteed floor 87.4%Product 12yr87.4%0yr5yr10yr15yr20yr25yr30yr
Projected outputGuaranteed floor: 87.4% at yr 30Product warranty ends yr 12

Wattage figure based on the sourced rated power (600 W) applied to the guaranteed floor; modular/format differences aside, this is the same rated-power spec shown above.

Modelled effective output, year by year

538W486W

Year 1 to year 25, at 30°C and 1000 W/m². Rated 600 W at STC.

How this is modelled

Compounds this panel’s own published first-year (1%) and annual (0.4%/yr) degradation figures against its 600 W rated (STC) output, then derates for the ambient and irradiance selected. Output is scaled roughly linearly with irradiance (1000W/m² against the 1000 W/m² STC reference). This is the dominant real-world effect at low light, whether from cloud, shading or soiling. Output is then further derated for heat, from this panel’s own NOCT (42°C) and temperature coefficient (-0.29%/°C), giving an estimated cell temperature of 58°C at that ambient and irradiance. A datasheet-derived estimate, not a field measurement or a warranty guarantee: it does not account for this panel’s own low-light efficiency response (a separate, less-consistently-published spec), or for wind and system design. See NOCT and temperature coefficient in the glossary.

Control panel

30°C
1000 W/m²
Year1510152025
Watts538 W529 W518 W508 W497 W486 W
% of rated89.7%88.2%86.4%84.6%82.8%81.0%
Before you buy
Local positionUse a market view to check local availability, approvals and warranty scope.
Ask the installerWill the quote name the exact PANDA 3.0 Pro model and wattage, and who covers labour if the module warranty is used?

Verification & sources

Market context

Global evidencechange in the site menu

Global benchmark. This scorecard is benchmarked globally. A global score does not imply local availability, certification, warranty coverage, or installer compatibility.

Benchmark anchor. The score uses the highest exact current power bin in the retained market source. Scored model: YL600CF72 e/2 · checked 2026-08-06. Evidence.

Australia buyer evidence

Australian warranty decision

0 product records

Read the Australian warranty as a claim pathway: the headline term is separate from remedy, labour, freight, site work, transfer and registration conditions.

No available Australian warranty decision record is published for this product. No coverage is inferred.

Sources & references · checked 2026-08-18

Strong evidence coverage

16 of 16 scored criteria link directly to a published source.

Values marked estimated, derived, or not found remain visible on the audit sheet and do not carry the same evidential weight as a linked source. Coverage measures direct links, not an independent guarantee that a claim is correct.

Record correction. Yingli PANDA 3.0 Pro 1 US datasheet V07 and glass-glass warranty V04 dated 2024-06-01 Corrected 2026-08-18: Cell technology tier set to TOPCon tier. The exact-model datasheet already established N-type TOPCon and the scoring field was simply empty, so the record was scoring its own missing-data floor.

Change ledger

Product record history

1 change to this record · 65 products changed in this update
  1. Record updated

    Durability (verified) pillar score

    Before
    49.5
    After
    49.6
    Primary datasheet
3 changes to this record · 106 products changed in this update
  1. Record updated

    Durability (verified) pillar score

    Before
    49.6
    After
    49.5
    Primary datasheet
  2. Record updated

    Global score

    Before
    60.9
    After
    61.5
    Primary datasheet
  3. Record updated

    Architecture & Design pillar score

    Before
    65.5
    After
    68.5
    Primary datasheet
6 changes to this record · 2 products changed in this update
  1. Record updated

    Source revision

    Before
    Yingli PANDA 3.0 Pro 1 US datasheet V07 and glass-glass warranty V04 dated 2024-06-01
    After
    Yingli PANDA 3.0 Pro 1 US datasheet V07 and glass-glass warranty V04 dated 2024-06-01 Corrected 2026-08-18: Cell technology tier set to TOPCon tier. The exact-model datasheet already established N-type TOPCon and the scoring field was simply empty, so the record was scoring its own missing-data floor.
    Primary datasheet
  2. Evidence added

    Cell technology tier

    Before
    Not previously recorded
    After
    TOPCon tier
    Cell technology tier
  3. Record updated

    Architecture & Design pillar score

    Before
    53.6
    After
    65.5
    Primary datasheet
  4. Evidence added

    Cell technology tier: Evidence sources

    Before
    Not previously recorded
    After
    https://www.yinglisolar.com/us/productInfo_264.html
    Cell technology tier
  5. Record updated

    Global score

    Before
    58.7
    After
    60.9
    Primary datasheet
  6. Evidence added

    Cell technology tier: Evidence status

    Before
    Not previously recorded
    After
    sourced
    Cell technology tier

This is review.solar's publication history. It does not claim the product changed on the recorded date, and it excludes compatibility, system pairing, installation suitability and relative leaderboard prose. Open the complete JSON record.

Evidence timeline

Recorded verification events for this scorecard. These are evidence checks, not historical score snapshots.

  1. Core scorecard evidence checked
  2. US market evidence checked
  3. Series benchmark evidence checked

Evidence record (JSON)

Scored by Solar Analytica Research

Stay across the benchmark.

New scorecards, score changes and market signals, published as they happen.